DX1000T/DX2000T

Touch Screen Model:
Touch screen operator interface provides faster and more intuitive access to common functions.

Features

Intuitive touch operation

  • Increases operator efficiency and menu navigation speed
  • Pressure-sensitive touch screen that gloved users can operate

Combined touch operation and key controls - your choice!

  • Use the touch screen to navigate all display and function menu selections, and to quickly input text information
  • Use the traditional control keys for all setting menu operations

Enhanced operation of your custom display screens

  • Build your own screens with the custom display functions
  • Operate a switch control or change a display with a touch of the screen

Easy search

  • Touch the calendar data search icon to quickly and easily search the trend history

Easy message, batch, login and electronic signature text entry (with /AS1 option)

  • Touch the screen to quickly and easily enter long batch and text messages
  • Login quickly to a secure DX; operators can select their username from a list and complete their login with the touch screen
  • Enter electronic signature - quickly examine trend history, approve the data, and enter signature comments with the touch screen
DX1000T_2 DX1000T_3
Touch operation on calendar display Touch operation for entering messages

 

Details

Resources

Please see the following page for recommended replacements for discontinued models. Information on discontinued products and recommended substitute models
All channels at once. MATH reset also occurs on all channels.
The longest is a 24-hour interval.
Can I reset integral values?
(ns-faq-dx-3039-spec)
If integrating with the TLOG calculation, you can reset it with the timer function.
Yes. You can display trends just as with measurement channels.
Can I set the clock externally?
(ns-faq-dx-3032-spec)
Yes, with the remote control function. This function sets the internal clock to the nearest hour (works if the current time is within 2 minutes of the hour).
This is controlled based on the rising or falling edge of the remote signal. For contact input, the signal rises when the contact changes from opened to closed, and falls from closed to opened. For open collector, the collector signal rises on Hi &ra...
With the remote control option (suffix code /R1), you can write 8 messages by registering them on up to 8 contact inputs in advance.
This is possible if you connect a PC to the network via Ethernet and set up a PC as an FTP server. Then, set up a DX account on the FTP server so that the DX can access it. Leave the FTP server running all of the time.
Are MATH channel values recorded?
(ns-faq-dx-3033-spec)
Yes. They are recorded just as with measured values.
Display, event, and report data files can be sent.
Display data records the max and min values during the recording period. The trend screen shows a line connecting the max and min values at each point in time, making the trend display appear filled in like a bar graph.
This assumes that the data type is display data. Display data records the max and min values during the recording interval, so those are the values it refers to.
DAQSTANDARD does not have a monitoring function. Please use DAQEXPLORER (sold separately).
How do I set the IP address of the DX?
(ns-faq-dx-3049-setting)
You set the IP address on the DX main unit.
From the web, you can access an operator page and a monitor page. On the operator page, you can switch screens from a web browser. You cannot switch screens on the monitor page.
Using FTP client software on the PC, you can transfer or delete files on external memory media. However, you cannot access the files in internal memory.
Yes, by using the Web server display function. After connecting to the network via Ethernet, you can type the DX's URL into a web browser on the PC (Internet Explorer, etc.) and view the screen that is currently displayed on the DX in the web bro...
The update interval of the web monitor page is approximately 30 seconds.
They are non-voltage contact or open collector (TTL level, 5 V).
Yes, with the email transmission function. When an alarm occurs, mail is sent to the specified email address.
Because the data type is set to display data. Display data is saved as the maximum and minimum values measured in the scan interval within the sampling interval. For details, see the following. Display and event data files ...
To change the save interval for display data, change the display update interval. Note that the unit of the display update interval is "/div," and 30 data are saved per div. Thus, for a display update interval of 30 min/div, the sampling in...
30 min/div. For details, see the following. Display and event data files
Display data: Measured data: 4 B/data; computed data: 8 B/data Event data: Measured data: 2 B/data; computed data: 4 B/data
Event data are the instantaneous values recorded at each scan interval. Display data are the maximum and minimum sampled values recorded within the display update time. For details, see the following. Display and event data files ...
Omitting the decimal point, the values that can be set for scaling are -30000 to 30000. 350.00 exceeds the setting range, and can't be entered. In this case, set it to "0.0–350.0".
The decimal place is determined by the scale lower limit value setting. Set the decimal place in the scaling lower limit value.
This means 1 scale division of the time axis on the trend screen.
The channel on which the alarm occurred, the time, and other information.
Can I view past display data?
(ns-faq-dx-3015-spec)
Yes. Using the Historical function, you can view a historical display of data in internal memory or external media.
No, the span or scaling range cannot be exceeded.
Yes, there is an Alarm Delay function. The function activates the alarm when the alarm state continues for a specified time.
Yes. You can view the list by using the DAQSTANDARD or other software.
What is Event data?
(ns-faq-dx-3017-spec)
Event data are the instantaneous values recorded at each sampling interval. They can be recorded at faster intervals than display data, and can therefore are used for analysis in greater detail.
Yes. Note that you can set the alarm relay output to OR or AND. By default, all alarm output terminals are set to OR, and the relay outputs if any of the assigned alarms occurs.
Four alarms (levels) can be set per channel. You can also set the same type of alarm for different levels.
This requires the alarm output relay option (suffix code /Ax). Note that the number of contact outputs that can be added depends on the model.
Can I record integral value data?
(ns-faq-dx-3038-spec)
By adding the MATH option (suffix code /M1), you can use a TLOG-based integral function. Using this operator, you can record integral data of a certain time.

Downloads

Looking for more information on our people, technology and solutions?

Contact Us

Top