After connecting two units of the DX100P/DX200P to GateDX-P, how can I connect to DAQLOGGER?

The following shows you how to assign 2 instances of Gate to DAQLOGGER. Launch GateDX-P, then click the ENVI button in DAQLOGGER manager.

  • After GateDX-P starts, click the ENVI button in DAQLOGGER manager.
  • Assign 2 Gates
  • Click the address field of the first Gate, enter the port number and address, check the system number specification, and then set it to 0.
  • Enter the same port number and address for the second Gate, and set the system number to 1.
    * When assigning the DX100P/DX200P on the GateDX-P side, the DX100P/DX200P assigned to "Number 1" is "System number 0," and the DX100P/DX200P assigned to "Number 2" is "System number 1."
  • Perform automatic model determination on each Gate.
  • Assign the DX100P/DX200P channels to tags.

 