The EJX910A is a Multivariable Pressure Transmitter. Featuring DPharp digital sensor technology, it offers the performance and device intelligence needed for greater process insight.
Details
The EJX910A multivariable pressure transmitter delivers precise measurements of differential pressure, static pressure, and process temperature. It features multi-sensing technology with a single-crystal silicon resonant sensor and covers multiple protocols, including HART, FOUNDATION Fieldbus, and RS485 Modbus.
- Utilizes DPHarp sensor technology
- Factory-programming available to specific primary elements
- Available in Mass Flow and Multi-Sensing Versions
Mass Flow Version | Multi-Sensing Version |
---|---|
|
|
What Are the Benefits of a Multivariable Pressure Transmitter?
The EJX910A with DPharp digital sensor offers the performance needed to run operations at peak performance. This ensures on-spec product, reduced waste, and improved yield, helping increase profitability.
Dynamic Compensation
All flow factors for mass flow calculation are dynamically compensated to an optimum value. The flow factors that are automatically compensated are: discharge coefficient, diameter of primary device, upstream internal pipe diameter, gas expansion factor, density, and viscosity.
Digital Performance
The DPharp sensor directly outputs a digital signal, eliminating the need for analog to digital conversion and improving performance.
Long-term Stability
When installed in the field, DP transmitters are subjected to continuous variations in pressure and temperature which will affect the accuracy. The performance may drift over time and is quantified using long term stability. There is unconditional guarantee of long-term stability under the complete range of operating conditions.
Standard Diagnostics
Standard
- 40 self-diagnostic checks to ensure that everything is running smoothly within the transmitter.
- The transmitter features a patented back-check technology that reverse checks all calculations in real-time.
- The DPHarp sensor is an active sensor, constantly supplying a signal even when the process has not changed. If the signal is lost from the sensor, the transmitter knows there is an issue.
Advanced
Predictive impulse line blocking and heat tracing diagnostics anticipate whether troubleshooting is needed.
Local Indicator
Easy to read indicator provides all the information you need. The indicator can display any of the variables measured (DP, SP, External Temperature); alarm codes with short text; and a sweeping bar graph to give a graphical representation of the process. Fully programmable, the indicator is customizable for your needs.
How to Reduce Total Cost of Ownership?
The EJX910A reduces total cost of ownership by having safety as standard, extending calibration intervals, and utilizing a common communication platform for all protocols.
Safety as Standard
All Yokogawa transmitters:
- Are designed and certified to IEC61508:2010 Parts 1 through 7 and IEC61511:2004 Parts 1 through 3 by Exida® and TÜV Rheinland®
- Are certified for single transmitter use in SIL2 safety applications and dual transmitter use in SIL3 safety applications
- Can be used for both process control and safety applications
Extended Calibration Check Intervals
When devices are initially installed, they operate at peak performance, but what happens after they are running under various process conditions and poorly managed or maintained?
Changing operating conditions can cause transmitters to drift to the point where they are no longer able to make accurate measurements for the process loop they are installed in, resulting in poor quality or an impact on product yields. This requires a calibration check interval to ensure you’re operating within desired error limits.
EJX-A series transmitters have a long-term stability of ±0.1% per 15 years under all operational conditions, reducing calibration frequencies and maintenance costs.
EJX910A Communication Protocols
HART Protocol
- 1.0% mass flow rate accuracy over 1:10 flow range
- Simultaneous dual output of 4 to 20mA and pulse signals
- HART protocol revision selectable from HART 5 or HART 7
- SIL 2 certified standard
FOUNDATION Fieldbus Protocol
- 1.0% mass flow rate accuracy over 1:10 flow range
- Various function blocks available: 5 AIs, AR, IT, SC, and IS standard
- PID is an optional feature
- Cyclically displays up to 10 values
RS485 Modbus Protocol
- Provides easy multi-sensing data transmission to flow computers
- Cyclically display up to 16 variables including RTU management data
- Up to 32 transmitters can be connected by multi-drop communication
- 32 character tag and squawk are supported for easy identification of transmitters
International Certifications
With the rapid globalization of markets, numerous international standards and approvals are becoming necessary. Yokogawa pressure transmitters have acquired various international certifications including FM, CSA, ATEX, IECEx, INMETRO, KOSHA, EAC, and NEPSI.
The proven DPharp technology of the EJX910A increases plant availability with its advanced diagnostics and quicker resolution of maintenance issues through multiple communication options. Verified by independent third parties around the world, our transmitter provides superior reliability and performance.
Rugged Construction
Proven Technology
Yokogawa’s DPharp sensor technology was developed in the early 1990s, and today, over 11 million Yokogawa transmitters and calibrators are installed using this technology.
Independent Third Party Verification
The performance and reliability of Yokogawa’s EJX-A transmitter series have been verified by independent third parties from around the world. From Safety System SIL rating to general performance evaluations, the EJX-A series has met or surpassed every test that it has been given.
FieldMate FlowNavigator™
FieldMate FlowNavigator™ is a PC-based software that is exclusively designed for use with the EJX910A / EJA930A. It uses FDT/DTM standards to enable users to configure mass flow and achieve accurate measurements with real-time full density compensation.
Manifolds
For Differential pressure transmitters, Yokogawa offers a complete line of IEC 61518 compliant 3-Valve and 5-Valve manifolds. Available in T-Style, H-Style, Wafer-Style, and Bottom Process Connection Style and can be ASME B31.1 (Power) Compliant, ISO 15848 Compliant, or TA-Luft Compliant.
3rd Party RTD Sensors and Thermowells
Yokogawa has partnered with Burns Engineering to offer industrial sensors. Burns Engineering provides a wide variety of sensor types (RTD or TC), thermowell materials, thermowell types, and immersion lengths for matching a wide range of customer requirements.
Direct-immersion RTD sensor (Thermowells Available)
Resources
The EJX910A with Micro-Orifice can measure ultralow flowrates for samples and carrier gases, and allows the technicians to access shelter readings remotely without performing time-consuming manual rounds.
Yokogawa's cost-effective and user-friendly, differential pressure volumetric flow measurement with accuracy ranging from 0.5% to 1.5%, ensures efficient process control at a competitive price compared to other flow technologies.
Downloads
Instruction Manuals
- EJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual (7.2 MB)
- ManualChange22-17E : DPharp EJX Series and EJA-E Series Differential Pressure and Pressure Transmitters (192 KB)
- Manual Change 22-24E: EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters (186 KB)
- EJX910A and EJX930A Multivariable Transmitter (5.2 MB)
- EJX910A and EJX930A Fieldbus Communication Type (3.1 MB)
- EJX910A and EJX930A Multivariable Transmitter HART Communication (13.3 MB)
- EJX910A and EJX930A Multivariable Transmitter Modbus Communication Type (3.8 MB)
- EJX/EJA-E series NEPSI Certification[Option code: /NF2, /NF21, /NS21, /NS24 and /NS25] (720 KB)
- EJX/EJA-E Series UKEX Certification [Option code:/BF21,/BS21,/BU21,/BS26 and /BN26] (1.5 MB)
General Specifications
Technical Information
- Functional Safety Manual (730 KB)
Engineering Tools
- EJX910A Multivariable Transmitter (366 KB)
- Drawings - EJX910A (Bottom Process Connection) (297 KB)
- Drawings - EJX910A/EJX930A (/N1 Option) (331 KB)
- Drawings - EJX910A/EJX930A (/N2 and /N3 Option) (333 KB)
- CMPL - EJX910A/EJX930A (Pressure-detector Section) (344 KB)
- /U1 Long Vent Plug (254 KB)
- 3D CAD Configurator - EJX910A
- CMPL - EJX910A/EJX930A (Transmitter Section) (295 KB)
Forms
- MVT101 (2) (111 KB)
Videos
Join Applications Engineer Michael Keller as he guides you through the steps for connecting the EJX910 Modbus with the USB Modbus converter.
Yokogawa presents a brief tutorial on configuring Stardom RTU to communicate with EJX Multivariable Pressure and Temperature transmitter via Modbus RTU over RS485. Appropriate function blocks and settings within Logic Designer are covered in order to read in the primary three variables DP, SP, and Temperature. Also a quick review of FieldMate and Kepware OPC Server are shown as examples of ways to review and change the settings of the EJX 910 Modbus MV transmitter.
2D/3D Configurator
Looking for more information on our people, technology and solutions?
Contact Us