Yokogawa's μR series strip chart recorder combines the digital chart recorder and paper chart recorder into one lightweight, splash-proof device, providing accurate high-resolution measurement charts that can withstand harsh production environments. The μR series can be used as a monitoring device as well as a quality control instrument in many applications such as pharmaceutical, chemical, power generation, heat treat, and environmental monitoring.
Accurate, High-Resolution Charts
- Can be programmed via the device’s communication interface or with the use of computer software
- RS422A/485 serial communication interface allows up to thirty-two units to be multi-drop connected to a single host computer
- LED internal illumination for greater visibility of the high-resolution chart selection
- Chart ejection function for immediate handwritten notes
- Dependable 24-Month Warranty
- IP54 Certification Standards
- Multi-View Display
- Large, Easy-to-read Display
- Internal LED Illumination & New Chart Cassette
- ASICs High Integration
- Powerful Math Functions
- Variety of Networking Functions
- SD Card Memory
- Application Software
- A Free Software Upgrade
- A Wealth of Recording and Printing Functions
- Calibration Correction
- 24 VDC/AC Power Supply (Option)
- Lightweight & Portable Type (Option)
Details
Servo Unit
The pen servo unit takes advantage of an ultra-small, rack-and-pinion stepping motor. The servo unit is smaller and consumes less power than previous models.
µR10000
ASICs High Integration
Achieved with none other than Yokogawa ASICs (application specific integrated circuits or custom ICs). ASICs increase integration while reducing power consumption, suppressing heat emissions, and increasing the lifespan of components.
High-Voltage Solid-State Scanner
For scanners that switch the input signal, Yokogawa's proprietary high withstand voltage, low leakage current MOS FETs and high voltage output photo couplers have been combined into a high withstand voltage semiconductor relay offering high speed (6 points per second) scanning, longer scanner life, and noiseless operation.
Navigational Display Makes Setup a Snap
All settings are interactive, and supported by the navigational display, offering superior ease of use.
µR10000 Navigation Display
Multi-Display (Displays a Variety of Screens) for Site Monitoring
"I want to use my recorder as a monitor." | |
µR10000 - 6 channel digital display (6 dot model) | µR20000 - 12 channel digital display (12, 18, and 24 dot models) |
2 channel digital display | 4 channel digital display |
"I want to monitor the recorder position on an analog indicator." |
|
µR10000 Flag display | µR20000 Flag display |
"I want to monitor alarms collectively." |
|
µR10000 Channel alarm status display | µR20000 Channel alarm status display |
LED Internal Illumination
This µR reflects advances in the chart cassette and internal illumination. Also, our new disposable pen (pen model), plotter pen, cassette ribbon (dot model), and chart paper maintain compatibility with previous models.
Chart Cassette
The chart cassette is equipped with a chart-ejection function. You can write memos on the chart and check the historical trend during recording.
µR10000 | µR20000 |
Lightweight
-
The latest molding techniques have been employed to decrease the number of parts by approximately 30% (compared to our previous 4-pen) or 20% (compared to our dot model).
-
Through the use of ASICs & new servo unit, we have achieved high efficiencies and low heat emissions in all of the 1-, 2-, 3, and 4-pen and 6-dot models while simultaneously limiting the weight to approximately 2.5 kg (6-dot model), and approximately 2.4 kg (4- pen model).
Portable (Option)
This model comes with a convenient carrying handle and portable power cord.
µR10000 | µR20000 |
Names of Parts
- Carrying handle
- Protective ground terminal (spare)
- Power terminal with protective ground terminal (attach the specified power cord)
- Feet (four)
Header Printout (Option, /BT1)
Manufacturing process information such as batch/lot number and comments can be printed out in synchronization with analog recording.
Example Printout (Pen Model)
*With the µR series, computed value can be included.
Notes:
- Bach name = batch number (characters)- lot number (4 or 6 digit number)
Example)
Batch number - 000001
batch number lot number (you can automatically increment by 1 when recording stops.) - Start printout/End printout: Printout operates like manual printout (stopped during analog recording).
- Message printout: During analog recording, you can print out messages that include measured* values.
(Measured* values, message strings, and date/time can be set arbitrarily.)
Basic operation
- When you start recording, the Start printout is performed.
- When you stop recording, the End printout is performed.
- During analog recording, you can print out messages that include measured* values.
This basic operation pattern is shown in the figure below.
Basic operation pattern
*With the µR series, computed value can be included.
Powerful Math Functions (/M1 Option)
Analog recording of computed results
Dot model:
Allows recording on all computation channels (12 ch). Recording can be turned ON/OFF on each channel.
Pen model:
You can assign measured or computed results to an arbitrary pen for recording.
Computation channels | Uses measurement channels, communication digital input, and remote input. |
---|---|
No. of computation channels | Pen models: 8ch dot models: 12 ch (µR10000), 24 ch (µR20000) |
Computations | The four arithmetic operations (+, -, ×, ÷), square root, absolute value, common logarithm (y=log10x), exponents (eX), and powers. Relational operators (<, >, ≤, ≥, =, ≠) Logical operations (AND, OR, NOT, XOR) |
Constants | 30 |
Communication digital input | Pen: 8 points, Dot: 12 points (µR10000), 24 points (µR20000) |
Remote input | Up to 5 remote inputs allowed. Remote status (0/1) can be used in equations. |
Equations | Up to 120 characters can be used |
Statistical computations | MAX, MIN, AVE, SUM, MAX-MIN |
A Wealth of Recording and Printing Functions
Printing Example
µR10000
4 pen model | 6 dot model |
24 dot model
Partial expanded recording Any important portion within the full scale can be expanded for recording. |
Zone recording Recording areas (zones) for each channel can be recorded separately. |
Calibration Correction (Option, /CC1)
This function enables minute adjustments when a certain correction is necessary due to deterioration of a sensor, or if measured values fall within the accuracy range but fluctuate relative to the displayed values on other instruments. Input signals are corrected based on a specified broken line, and its values are measured.
Number of Set Points
You can select the number of points that make up the segments (including the start and end points) in the range of 2 to 16.
Using revision values
Using absolute values
Corrected value (B4) of the fourth set point = a ? b
Example of the Input Values
Input Value | Corrected Value | Revision Value | Absolute Value |
---|---|---|---|
9.8° | 10.0° | 0.2° | 10.0° |
90.5° | 90.0° | -0.5° | 90.0° |
24 VDC/AC Power Supply (Option, /P1)
The unit can be powered under 24 VDA or 24 VAC.
- Rated power supply: 24 VDC/AC
- Allowable power supply voltage range: 21.6 to 26.4 VDC/AC
- Dielectric strength:
- Power supply to ground terminal: 1000 VAC
- Power consumption (approx.):
Supply Voltage | Max. |
---|---|
24 VDC | Approx. 50 VA |
24 VAC (50/60 Hz) | Approx. 60 VA |
Portable Type (Option, /H5[ ] )
This model comes with a convenient carrying handle and portable power cord.
Names of Parts
µR10000 | µR20000 |
- Carrying handle
- Protective ground terminal (spare)
- Power terminal with protective ground terminal (attache the specified power cord)
- Feet (four)
Specifications
SD Memory
- SD card (up to 32 GB) enables long-duration recording
- Provides backup and recall if chart data is lost due to paper jams or ink problems
- Save main unit settings such as input ranges and alarms to SD card for reuse when replacing or adding instruments.
Network Communication
RS422A/485 Serial communication interface allows up to thirty-two units to be multi-drop connected to a single host computer. Ethernet is also included for support of high-speed communication and LAN environments.
Software Options
SMARTDAC+ Parameter Setting Software is available (sold separately). Settings can be entered via this communication interface.
Dependable 24-Month Warranty
- Backed by the high reliability and quality that Yokogawa has cultivated over many years.
Yokogawa's Global Support
- Yokogawa supplies product around the world and has the reach to assist your customer with support and service on whatever shores your original equipment lands.
Splash-Proof Front Door
- IP54 certification standards in panel mount installation (conforms to Din 40050-IP54).
Safety/EMC Standards
Yokogawa's highly reliable industrial recorders support safety and EMC (electromagnetic compatibility) standards.
EMI testing LAB in Yokogawa
µR Series conforms to the European CE marking standard
IP54 certification standards in panel mount installation (conforms to Din 40050-IP54)
-
【Support Information】List of Verified SD Memory Cards (SD Cards)
The SD cards of the following manufacturers have been verified for use with SMARTDAC+ GX/GP/GM, μR10000/μR20000 and FX1000. However, please note that Yokogawa does not guarantee normal operation of the SD card when using with products listed below.
-
【Support Information】Recorder's Consumables (Chart Papers, Pens, Ribbon cassettes)
Recorder's Consumables (Chart Papers, Pens, Ribbon cassettes)
-
【Support Information】List of RoHS
This is a list of recorder and controller products that support the RoHS (2011/65/EU) directive.
-
【Support Information】PC Software Support Model List
list of compatible models which various PC software is supported.
-
【Support Information】New Legislative Framework (NLF) Conforming Products
This is a list of recorder and controller products that support the New Legislative Framework (NLF.)
Resources
The Japan Steel Works, LTD., Muroran Plant uses the Control and Measurement Station CX2000, UP series program controllers, and UT series digital indicating controllers for operation of its heat treating furnaces. The Japan Steel Works (JSW), LTD., Muroran Plant is located in an industrial area looking over Muroran port in Muroran City, Hokkaido.
By using the computation function of the SMARTDAC+ series Paperless recorder GX/GP, computation option computes the "F-value," or sterilizing value for the sterilization process, so that the computation results can be recorded in the form of data.
Downloads
Brochures
- Intelligent Industrial Recorders μR10000/μR20000 (4.8 MB)
- Intelligent Industrial Recorders (1.3 MB)
- Recorder Migration Guide (1.4 MB)
Instruction Manuals
- Proper Disposal of This Product/ How to Replace and/or Dispose the Batteries (559 KB)
- MicroR10000 / MicroR20000 Usage Precautions (637 KB)
- MicroR20000 Recorder User's Manual (21.0 MB)
- MicroR10000 Recorder User's Manual (16.6 MB)
- MicroR10000 Recorder Operation Guide (9.5 MB)
- MicroR10000/MicroR20000 Communication Interface User's Manual (2.1 MB)
- MicroR20000 Recorder Operation Guide (11.6 MB)
- RXA10-01 and RXA10-02 Configuration Software User's Manual (1.9 MB)
- *Discontinued: WX1 Gate µR User's Manual (665 KB)
- Service Manual: Model 436101/436102/436103/436104/436106 μR10000 (4.3 MB)
- MicroR10000/MicroR20000 SD Memory Card (/EM1 Option) User's Manual (2.3 MB)
- Control of Pollution Caused by the Product (152 KB)
- Control of Pollution Caused by the Product (170 KB)
- Service Manual: Model 437101/437102/437103/437104/ 437106/437112/437118/437124 μR20000 (5.3 MB)
- μR10000 Recorder Portable Type (245 KB)
- μR10000/μR20000 Usage Precautions (204 KB)
- μR20000 Recorder Portable Type (322 KB)
General Specifications
- μR10000 Recorder (5.8 MB)
- New Legislative Framework (NLF) Conforming Products (362 KB)
- μR20000 Recorder (6.9 MB)
- List of RoHS (2011/65/EU) Directive Compliant Products (6-substances RoHS compliant products) (356 KB)
- 438920, 438921 and 438922 Shunt Resistor for Clamp Input Terminal (252 KB)
- List of the US Toxic Substances Control Act (TSCA) Compliant Recorder and Controller Products (175 KB)
- 415920, 415921 and 415922 Shunt Resistor for Screw Input Terminal (240 KB)
Technical Information
- μR10000 Overview (1.0 MB)
- μR20000 Overview (3.3 MB)
- μR10000 Comparative Table(μR10000 vs μR1000)/μR20000 Comparative Table(μR20000 vs μR1800) (367 KB)
- Noise Interference on Recorder (781 KB)
Engineering Tools
- μR20000 Recorder (Pen Model) (514 KB)
- Custmer Maintenance Parts List: Model 437106,12,18,24 μR20000 Recorder Dot Model (5.5 MB)
- μR20000 Recorder (Dot Model) (1.6 MB)
- Customer Maintenance Parts List: Model 436101 (1-pen), 436102 (2-pen) 436103 (3-pen), 436104 (4-pen) μR10000 pen recorder (4.6 MB)
- Customer Maintenance Parts List: Model 436106 μR10000 6dot recorder (4.2 MB)
- Customer Maintenance Parts List: Model 437101,02,03,04 μR20000 Recorder Pen Model (5.0 MB)
Videos
Yokogawa's Network Solution Group presents a video tutorial on configuring DAQLogger with Gate MR and a uR20000 Paper Recorder. This tutorial goes through a basic configuration of a uR20000 as used in a Regenerative Thermal Oxidizer (RTO) Title V Air Quality application. It includes totalizing flow in SCF (from SCFM) and averaging temperature in 3 hour segments. The tutorial then goes through making a connection with Gate MR, importing tags and groups into DAQLogger and using DAQLogger to trend and record data.
Yokogawa's Network Solution Group presents a video tutorial on configuring DAQLogger with Gate MR and a uR20000 Paper Recorder. This tutorial goes through a basic configuration of a uR20000 as used in a Regenerative Thermal Oxidizer (RTO) Title V Air Quality application. It includes totalizing flow in SCF (from SCFM) and averaging temperature in 3 hour segments. The tutorial then goes through making a connection with Gate MR, importing tags and groups into DAQLogger and using DAQLogger to trend and record data.
Yokogawa's Network Solution Group presents a video tutorial on configuring DAQLogger with Gate MR and a uR20000 Paper Recorder. This tutorial goes through a basic configuration of a uR20000 as used in a Regenerative Thermal Oxidizer (RTO) Title V Air Quality application. It includes totalizing flow in SCF (from SCFM) and averaging temperature in 3 hour segments. The tutorial then goes through making a connection with Gate MR, importing tags and groups into DAQLogger and using DAQLogger to trend and record data.
Looking for more information on our people, technology and solutions?
Contact Us