Built upon Yokogawa's second generation of TDLS analyzers, the TDLS8220 houses all the industry's leading features in one robust device. The improved platform is designed for accurate, low maintenance, and reliable extractive oxygen measurements of process gas streams.
Details
Features
- Analyzer, flow cell, heat trace control, insulation, purge control, and wiring termination pre-integrated
- Drop-in replacement for existing analyzer technologies
- Integrated tube-in-shell flow cell allows for tight sample heating control
- Pressure and temperature compensation included
- Advanced diagnostics with 50 days of data and spectra storage
Reliability
Reference Cell
Internal reference cell in the laser module ensures peak locking during trace measurement.
Auto gain
Auto-gain enables wide signal ranges against dynamic variation of transmission.
Validation
Validation can be initiated manually, remotely, or automatically on a daily, weekly or monthly basis defined by the user.
TruePeak
With TruePeak we can measure the area of the absorbance peak. This eliminates effects from changing background gases, allowing for simple pressure and temperature compensation.
Intuitive Touchscreen HMI
- Touch screen 7.5 inch color LCD on HMI
- Simple operation
- Provides full analzyer control and access to monitoring, historical files, and confiugrations
- Remote installation with the ability to connect up to 4 different TDLS analyzers
HMI Trend Display
Standard Specifications
Measurement object | O2 | |||
---|---|---|---|---|
Measurement system | Tunable diode laser spectroscopy | |||
Measured components and range | Measured component | Min. range | Max. range | |
O2 | 0-1% | 0-25% | ||
Output signal |
2 points, 4 to 20 mA DC Output types; Gas concentration, Transmission, Process gas temperature, Process gas pressure Output range; 3.0 to 21.6 mA DC |
|||
Digital communication | HART, Ethernet, Modbus/TCP | |||
Contact outputs |
2 points, contact rating 24 V DC, 1 A DO; Function: Activate during Warning / Calibration / Validation / Warm up / Maintenance conditions Fault; Function: Activate during normal condition, not activate during fault condition or when the system power is off |
|||
Valve control output | 2 points Function; Activate calibration or validation solenoid valves for zero, span or validation gas Output signal; 24 V DC, 500 mA Max. per terminal |
|||
Alarm | Warning; Gas concentration low/high, Transmission low, Process pressure low/high, Process temperature low/high, Validation required, Validation failure, Zero/Span calibration error, Non process alarm, External alarm Fault; Laser module temperature low/high, Laser temperature low/high, Detector signal high, Peak center out of range, Reference peak height low, Absorption too high, Transmission lost, Reference transmission low, Reference peak height high, Laser unit failure, Laser module error, File access error, E2PROM access error. |
|||
Contact inputs |
2 points Function; External alarm/Calibration start/Validation start/Stream switch Contact specification; Zero voltage contact input Input signal; Open signal; 100 kΩ or more, Close signal; 200 Ω or less |
|||
Input signal |
2 points, 4 to 24 mA DC Input types; Process gas pressure, Process gas temperature |
|||
Self-diagnostics | Laser Unit temperature, Sensor Control Unit temperature, Laser temperature, Detector signal level, Memory read/write function, Peak locking condition | |||
Calibration | Calibration method; Zero/Span calibration Calibration mode; Manual, Auto, Local initiate (HMI) |
|||
Validation | Validation method; Up to 2 points Validation mode; Manual, Auto, Local initiate (HMI) |
|||
Warm-up time | 5 min. | |||
Protection degree | IP65 | |||
Hazardous area classifications | The analyzer is designed fo operation in hazardous area for gaseous release. Class 1 Division 2 Groups A, B, C, D with purge system. | |||
Sample gas condition | Sample gas temperature: Max 120°C Sample gas pressure: 90 to 500 kPa absolute |
|||
Installation condition | Ambient operating temperature: -20 to +55°C Humidity: 0 to 95%RH at 40°C (non-condensing) |
YH8000 HMI Unit
Display | Touchscreen 7.5 inch TFT color LCD panel, 640 x 480 (VGA) |
---|---|
Communication | Ethernet; RJ-45 connector, Communication speed; 100 Mbps |
Protection degree of enclosure |
IP65, NEMA Type 4X |
Weight | 4 kg |
Mounting | Analyzer mount (Front, left-side, right-side) with tilt function, Pipe mount or Panel mount |
Cable Entries | 1/2NPT or M20 x 2 |
Installation conditions |
Ambient operating temperature; -20 to 55℃ Storage temperature: -30 to 70℃ Humidity: 10 to 90%RH at 40℃ (Noncondensing) |
Power Supply | 24 V DC ±10% |
Hazardous area classifications |
Division 2, Zone2: Non-Incendive/Type n; FM, cFM, ATEX, IECEx |
Resources
Enhance the efficiency and safety of your vapor recovery systems and flare/vent headers with Yokogawa's cutting-edge Tunable Diode Laser Spectrometers – the TDLS8000 and TDLS8220. Elevate your oxygen measurement capabilities with our interference-free analyzers, providing direct measurements. Experience unparalleled reliability, ensuring minimal upkeep and secure operations without the need for system shutdowns.
Enhance the efficiency and safety of your vapor recovery systems and flare/vent headers with Yokogawa's cutting-edge Tunable Diode Laser Spectrometers – the TDLS8000 and TDLS8220. Elevate your oxygen measurement capabilities with our interference-free analyzers, providing direct measurements. Experience unparalleled reliability, ensuring minimal upkeep and secure operations without the need for system shutdowns.
Blue ammonia represents a significant opportunity for the ammonia industry. Unlike “green” ammonia, which relies on renewable energy and is still in the early stages of development, blue ammonia can be produced using much of the same infrastructure already in place for grey ammonia.
Downloads
Looking for more information on our people, technology and solutions?
Contact Us