For test applications with data logging requirements, the MX100 scales from four to 1200 channels. It streams, records, displays, and reports with no programming required.
When combined with Yokogawa's turnkey PC software, the MX100's multi-channel capability and high isolation voltage offer the ultimate in measurement power.
Details
High Performance
Multi-Channel Capability, High Isoration Voltage
- Shortest measurement interval of 10 ms (high-speed measurement of 10 ms on 24 channels or 100 ms on 60 channels is possible).
- Possible to acquire data from up to 1,200 channels (when using Yokogawa's proprietary software).
- Reinforced insulation between the input terminal and the case handles 3700 Vrms for one minute, or 600 Vrms/VDC continuous.
Multi-Interval Measurement
- Mixed use of three types of measurement intervals is enabled within the system (measurement intervals are set for each module).
Easier to Use
Flexible System Configuration
- By configuring modules, a system can be built or modified to utilize 4 to 1,200 channels, and measurement intervals of 10 ms to 60 s.
Versatile PC-Based Software Options
- Software developed by Yokogawa, an API, and a LabVIEW driver are available.
Easy Software Setup
- PC software developed by Yokogawa automatically identifies any connected MX100s.
High-Speed, Multi-Channel Capability
The table below provides reference information on the maximum number of measurable channels in relevant measurement intervals (when using Yokogawa's proprietary software):
Measurement interval | Maximum number of measurable channels | Measurable objects | PC software | Number of necessary modules (example) | |||
---|---|---|---|---|---|---|---|
MX100 Standard software | MXLOGGER | Main Module (MX100) | Four-channel High-speed Universal Input Module (MX110-UNV-H04) | Ten-channel Medium-speed Universal Input Module (MX110-UNV-M10) | |||
10 ms | 24 channels | DCV/DI | √ | √ | 1 | 6 | — |
50 ms | 24 channels | DCV/TC/RTD/DI | √ | √ | 1 | 6 | — |
50 ms | 120 channels | DCV/TC/RTD/DI | — | √ | 5 | 30 | — |
100 ms | 60 channels | DCV/TC/RTD/DI | √ | √ | 1 | 0 | 6 |
200 ms | 500 channels | DCV/TC/RTD/DI | — | √ | 9 | 0 | 50 |
500 ms | 600 channels | DCV/TC/RTD/DI | — | √ | 10 | 0 | 60 |
1000 ms | 1200 channels | DCV/TC/RTD/DI | — | √ | 20 | 0 | 120 |
√ measurement that support is possible
— measurement that support is not possible
The relationship between measurement intervals and the number of channels largely depends on the performance of the PC. The actual performance may differ from that shown in the table.
CPU: Pentium 4 3.2 GHz; Memory: 1 GB; OS: Windows 2000; Hard disk: 160 GB
Communication interface: Ethernet 100Base-TX
Multi-Interval Measurement
Three types of measurement intervals can be used in a single system in various combinations. Measurement intervals are specified for each module. It is also possible to set different types of input modules to the same measurement interval or to set the same type of input modules to different measurement intervals. Twelve measurement intervals are available as userselectable options: 10 ms, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 20 s, 30 s and 60 s. Please note, however, that measurement intervals of 10/50 ms cannot be set to the Medium-speed Universal Input Module (MX110-UNV-M10).
Multi-interval systems can be flexibly built for each module as shown in the figure below. Three colors are used to indicate the three types of measurement intervals.
Examples of Setting Measurement Intervals
Monitor Window Using Yokogawa's Proprietary PC Software
The window shows measurement values by measurement intervals. Measurement can be performed while confirming rapidly-changing signals and slowly-changing signals simultaneously.
A: Measurement of sine waves at 0.5 Hz with a measurement interval of 100 ms
B: Measurement of sine waves at 8 Hz with a measurement interval of 10 ms
C: Measurement of sine waves at 1 Hz with a measurement interval of 50 ms
High Withstand Voltage (Reinforced Insulation)
Reinforced (double) insulation has been provided between the input terminals and the case to achieve a high withstand voltage of 600 Vrms/VDC (continuous). As shown below, each battery voltage can be measured even if the batteries are stacked to increase common-mode voltages.
Noise Rejection (MX110-UNV-H04)
MX input modules employ integrating A/D converters with superior noise rejection performance. In particular, the MX110-UNV-H04 Four-Channel High-Speed Universal Input Module incorporates an integrating A/D converter for each input channel, thereby exhibiting strong noise rejection performance in high-speed measurement. Moreover, the digital filtering function is effective on noises that cannot be fully rejected even with integrating A/D converters. Time constants can be selected from 5 to 100 measurement interval times. Therefore, filtering can be applied according to the noise to be rejected.
Example of Noise Rejection
When the noise source in the left figure was applied to the MX, the result in the right figure was obtained. High-speed measurement can be stably performed even in noisy environments.
Noise source applied to the MX A noise signal was applied between H and L (in normal mode). |
Output window of MX100 for noise inputs Module used: MX110-UNV-H04 Four-Channel High-Speed Universal Input Module Measurement with the range of 2 V (-2 V to +2 V), measurement interval of 50 ms, integral time "Auto" and filter & "OFF." |
System Configuration
Connection between a single MX unit and a single PC |
One MX unit enables data acquisition on up to 24 channels at a measurement interval of 10 ms, or up to 60 channels at a measurement interval of 100 ms (six modules installed in both cases).
Input signal
DC voltageThermocuple, RTD, Digital input (mixed input possible)
Output signal
Digital output
Setting up the System
The MX and PC are connected via a hub and a straight Ethernet cable.
Alternatively, they can be connected using a cross cable alone, without using the hub.
PC Software
In a one-to-one connection, the MX100 standard software included with the main module facilitates easy building of data acquisition environments.
One MX unit consists of a combination of a main module, input/output modules, and a base plate. This configuration centers on the main module.
Connection between multiple MX units and a single PC
Example of a system with multiple MX units |
Setting up the System
The MX units and the PC are connected by means of a hub and straight Ethernet cables.
PC Software
Acquisition of data from multiple MX units is well-supported by Yokogawa's software "MXLOGGER" (optional). MXLOGGER enables data acquisitions of up to 20 MX units (one unit has inputs of up to 60 channels, or 1,200 channels on 20 units).
Please note that the shortest measurement interval of MXLOGGER depends on the system's total number of channels and the PC's performance.
If users wish to create their own data acquisition software, there is no limit to the number of MX units that can be integrated with a single PC software element. Please note, however, that if conditions with heavy loads (such as short measurement intervals with many units) are set to the PC and its software, data will not be acquired in time and some data may be lost.
Input Modules
Name | Model | No. of channels | Shortest measurement interval | Description |
---|---|---|---|---|
30 ch general purpose input module with 500 ms scan speed | MX110-VTDL30 | 30 | 500 ms | Clamp terminal, DCV/TC/DI |
MX110-VTDL30/H3 | 30 | 500 ms | M3 screw terminal, DCV/TC/DI |
Name | Model | No. of channels | Shortest measurement interval | Description |
---|---|---|---|---|
Universal Input Modules | MX110-UNV-H04 | 4 | 10 ms | DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed. |
MX110-UNV-M10 | 10 | 100 ms | DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed. | |
4-Wire RTD and Resistance Input Module | MX110-V4R-M06 | 6 | 100 ms | DC voltage, 4-wire RTD, 4-wire resistance, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed. |
Strain Input Modules | MX112-B12-M04 | 4 | 100 ms | Built-in bridge resistance of 120 ohm |
MX112-B35-M04 | Built-in bridge resistance of 350 ohm | |||
MX112-NDI-M04 | For connection with an external bridge head and strain gauge type sensor (NDIS connector)) | |||
5 V Digital Input Module | MX115-D05-H10 | 10 | 10 ms | Non-voltage contact, open collector, and Level (5 V logic). Mixed input allowed. |
24 V Digital Input Module | MX115-D24-H10 | 10 | 10 ms | Level (24 V logic), Vth = 12 V |
Output Modules
Name | Model | No. of channels | Output update interval | Description |
---|---|---|---|---|
Analog Output Module | MX120-VAO-M08 | 8 | 100 ms | Allows mixed voltage (±10 V) and current (4-20 mA) output |
PWM Output Module | MX120-PWM-M08 | 8 | 100 ms | Pulse width modulation output module |
Digital Output Module | MX125-MKC-M10 | 10 | 100 ms | "A" contact (SPST) |
Base Plate
Base plates available for all configurations, from 1 to 6 input/output modules.
When used for the MW100/MX100, you must replace the attachment with the one that comes standard with the MW100/MX100.
Accessories
Connector Covers Connector covers for open slots
AC Adapter (772075) AC adapter for the DC power model.
Operating temperature range: 0 to 40°
*Only for the MW100
Accesories (Removable Terminal)
All input/output terminals are removable except for those of the MX112-NDI-M04. If multiple terminals are prepared ahead of time, no re-wiring is needed between measurements.
Model | Description |
---|---|
772061 | Screw (M4) terminal block (RJC (reference junction compensation) included). For use in combination with 772062. Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10. |
772062 | Connection cable between input modules and the screw terminal block. Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10. |
772063 | Plate with clamp terminals (RJC included). Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10. |
772064 | Clamp terminals. Compatible with MX110-UNV-H04. |
772065 | Clamp terminals. Compatible with MX120-VAO-M08, MX120-PWM-M08, and MX125-MKC-M10. |
772067 | Plate with clamp terminals. Compatible with MX110-V4R-M06. |
772068 | Plate with clamp terminals (Built-in bridge resistance of 120 ohm). Compatible with MX112-Bxx-M04. |
772069 | Plate with clamp terminals (Built-in bridge resistance of 350 ohm). Compatible with MX112-Bxx-M04. |
772080 | Plate with screw (M3) terminal (RJC included). Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10. |
772081 | Plate with clamp terminal for current with 10 ohm built in bridge resistance, applies to MX110-UNV-M10 |
772082 | Plate with clamp terminal for current with 100 ohm built in bridge resistance, applies to MX110-UNV-M10 |
772083 | Plate with clamp terminal for current with 250 ohm built in bridge resistance, applies to MX110-UNV-M10 |
Mounting on Racks or Panels Using the DIN Rail
Use the DIN rail for mounting on on racks or panels. The DIN rail can be easily attached using the dedicated bracket. Two brackets come standard with the base plate (MX150).
Use the DIN rail for mounting on racks or panels. The DIN rail can be easily attached using the dedicated bracket. Two brackets come standard with the base plate (MX150).
Software
This software is used to connect a single MX unit for performing data acquisition (it is not possible to connect multiple MX units). It includes three software elements: the integration monitor, viewer, and calibration.
Integration Monitor Software
This software performs real-time monitoring and logging of measured data. It consists of six menus: Monitor Window, Detailed Display Setting, Channel Setting, Acquisition Condition, System Setting, and Connection/disconnection.
MXLOGGER (Optional PC Software)
MXLOGGER is used to connect multiple MX units (up to 20 units) for data acquisition (one MX unit can also be connected). It consists of software elements (setting, logger (for saving data), monitor, and viewer) and the monitor server. The monitor server function is used to enable connections with Yokogawa's data logging software, "GA10." It is effective when combining MX units with Yokogawa's data acquisition equipment such as DARWIN and DAQSTATION.
API for MX100/DARWIN (Optional)
If users wish to create their own data acquisition software, please use this API. The API consists of a suite of functions to communicate with MX100/DARWIN. The suite of functions contains DLL (dynamic link library). API makes it possible to create data acquisition software dedicated to the MX, or data acquisition software combining the MX and DARWIN, or data acquisition software dedicated to DARWIN. Three languages (Visual C, Visual C++, and Visual Basic) are supported.
-
【Support Information】List of RoHS
This is a list of recorder and controller products that support the RoHS (2011/65/EU) directive.
-
【Support Information】New Legislative Framework (NLF) Conforming Products
This is a list of recorder and controller products that support the New Legislative Framework (NLF.)
-
【Support Information】PC Software Support Model List
list of compatible models which various PC software is supported.
Resources
Rinnai uses the MX100 PC-based High-speed Data Acquisition Unit for evaluation and testing of its kitchen appliances.
Denso uses the MX100 PC-Based High-Speed Data Acquisition Unit for performance evaluation of its car air conditioners.
Downloads
Brochures
Instruction Manuals
- *Discontinued: Model MX190 API for MX100/DARWIN (2.4 MB)
- *Discontinued: API for the MX100/DARWIN First Step Guide (442 KB)
- *Discontinued: MX100 Data Acquisition Unit User's Manual (6.0 MB)
- *Discontinued: MX100 Data Acquisition Unit Operation Guide (2.6 MB)
- MX100 Compliant with Safety Standards (IEC/EN/UL/ CSA 61010-1 3rd edition) (135 KB)
- *Discontinued: MX100 Standard Software User's Manual (4.7 MB)
- *Discontinued: MX100 Style Upgrade Guide (105 KB)
- *Discontinued: MX100/MW100 Data Acquisition Unit Installation and Connection Guide (1.9 MB)
- *Discontinued: MX100/MW100 Handling of the 10-CH Screw Terminal Block (772061) (419 KB)
- *Discontinued: MX100/MW100 Handling of the Base Plate (796 KB)
- *Discontinued: MX100/MW100 Handling of the Input/Output Modules (512 KB)
- *Discontinued: MX100/MW100 Handling of the Plate with Screw Terminals (772080) (573 KB)
- *Discontinued: MX100/MW100 Quick Start Package Checking the Contents of the Package (359 KB)
- *Discontinued: MX100/MW100 Setting Up the Plate with Clamp Terminals for Current (772081/772082/772083) (569 KB)
- *Discontinued: Precaution on the Use of MX100/MW100 (43 KB)
- WX1000 DAQWORX Installation & Operation Guide (3.0 MB)
- *Discontinued: WX103 MXLOGGER User's Manual (5.0 MB)
- *Discontinued: WX1 GateMX/MW User's Manual (660 KB)
- Notice of Alterations: MW100 Viewer Software (3.6 MB)
- *Discontinued: WX101 DAQLOGGER WX81 DAQLOGGER Client Package (12.1 MB)
- *Discontinued: WX201 DataBrowser User's Manual (6.1 MB)
- Notice of Alterations: MX100 Standard Software (3.6 MB)
- *Discontinued: MX100/MW100 Control of Pollution Caused by the Product (522 KB)
- *Discontinued: MX100/MW100 Control of Pollution Caused by the Product (268 KB)
- Notice of Alterations: WX1000 DAQWORX Installation & Operation Guide (1.9 MB)
- Proper Disposal of This Product/ How to Replace and/or Dispose the Batteries (559 KB)
- Service Manual: MX100/MW100 Data Acquisition Unit (14.8 MB)
General Specifications
Software
- MX100 Standard Software (16.7 MB)
Technical Information
Videos
Yokogawa's Network Solution Group is pleased to present a video walk-through of configuring DAQLogger and Gate MW MX for use with the MW100 and MX100 data acquisition units. DAQLogger allows data to be recorded in real-time from field units like the MW100 (DAQMaster) and MX100 as well as other Yokogawa data recording products like the DAQStation family. Gate MW MX is the communication driver that allows DAQLogger to connect to MW100 and MX100 units. DAQLogger supports real-time and historical views of recorded data as well as reports and events.
Yokogawa's Network Solutions Group is pleased to present a quick walk through of MXLogger Data Acquisition Software for DAQMaster MX100 based hardware platform. MXLogger allows for up to 1200 points of data to be simultaneously logged from up to 20 networked MX100 data acquisition units. Each MX100 unit can have up to 60 inputs such as thermocouples, RTDs, volts DC, mA (via shunt), and digital inputs as well as several other types of inputs and outputs. MXLogger also incorporates a powerful math channel (virtual channel) system for computations and logical decisions as well as a powerful event engine.
Yokogawa's Network Solutions Group is pleased to present a quick walk through of MXStandard Data Acquisition Software for DAQMaster MX100 based hardware platform. MXStandard allows for up to 60 points of data to be simultaneously logged from a single MX100 data acquisition unit. A MX100 unit can have up to 60 inputs such as thermocouples, RTDs, volts DC, mA (via shunt), and digital inputs as well as several other types of inputs and outputs. MXStandard also incorporates a powerful math channel (virtual channel) system for computations and logical decisions.
Looking for more information on our people, technology and solutions?
Contact Us