Introduction
Most zinc are produced at hydrometallurgically, where a high-grade zinc product can be obtained and valuable metals mixed in the raw material can be recovered. In the hydrometallurgy, the raw material of zinc concentrate is roasted and then dissolved in sulfuric acid to remove impurities. The process called leaching and pH control of the leachate is important. The leachate contains gypsum and impurities that may cause scaling on electrodes. As a result, it interfered with stable pH measurement and required frequent cleaning at least once a week. A pH analyzer with air jet cleaning system provides continuous cleaning and therefore can reduce maintenance frequency to once every one or two months.
Expected Benefits
- Ensures stable and continuous pH measurement
- Reduces operating costs
- Eliminates manual cleaning work by hand
Process Overview
Roasted concentrate sent from a roasting furnace, is dissolved in diluted sulfuric acid (spent electrolyte) in a dissolving tank.
ZnO + H2SO4 -> ZnSO4 + H2O
In addition, some iron and other material contained in the calcine are dissolved. Therefore, these impurities are removed by precipitation by adding manganese, lime or other additives.
FeO + Additive -> Fe2O3 (precipitation)
pH control is important to allow zinc to dissolve fully and impurities to precipitate maximally. The leachate is filtered by a filter press to remove impurities and the filtrate is fed to an electrolytic bath where zinc is electrolytically produced.
Electrolytic Zinc Manufacturing Process
Solution Details
Measurement system
4-wire pH measurement system (with jet cleaning system) | |
---|---|
Sensor | KCl refillable pH sensor (Teflon liquid junction) PH8EFP-□□-TN-TT1-N-G*A/TF |
Holder | Submersion type holder with jet cleaning system PH8HS-PP- □□ -T-JT-JP*A/MS3 |
Terminal box (when needed) | WTB10-PH3 |
4-wire pH/ORP converter | FLXA402-A-B- □□ -P1-NN-A2-WR- □ - □ -N-NN/UM |
Utilities
FLXA402 4-Wire Converter | |
---|---|
Power supply | 90 to 264 V AC, 50/60 Hz |
Power consumption | 35VA maximum |
Submersion holder | |
Air for jet cleaning | |
Air pressure | 200 to 400 kPa |
Consumption | 100 to 300 NL/min |
Notes
- Continuous air jet cleaning
Since the leachate is a strongly acid solution, its pH value is not affected by air cleaning. This allows measurement and cleaning simultaneously. - Other applications
This cleaning system can be used for other smelting processes of copper, manganese, sadmium, etc.
Field Data
Process condition
Measurement point: | Leachate in the dissolving tank |
---|---|
Temperature: | 80°C |
pH value: | pH 1.5 ± 0.2 |
Zinc: | Approx. 160 g/L |
Sulfuric acid: | 2 to 3 g/L |
Lime: | Saturated |
Before air jet cleaning system was introduced, the cleaning work by hand had been required at least once a week. Continuous air jet cleaning using the submersion holder with jet cleaning system, has reduced the maintenance frequency to once a month or two months.
To ensure stable measurement, the pH sensor uses a Teflon liquid junction, where the KCl outflow is higher than that of ceramic junction.
產業別
相關產品&解決方案
-
FU20/FU24/PH20一體化pH/ORP (REDOX)傳感器
PH20/FU20/FU24一體化pH/ORP傳感器體現了橫河電機如何將“簡單即好”這句格言應用於傳感器技術。
-
四線式液體分析計 FLXA402
The FLEXA™ 系列分析計是模組化設計的分析計,用於工業裝定中的連續線上測量。提供單一或多sensor測量。
-
數位 SMART SENCOM™ 轉接器: SA11
可重複使用的 SMART 轉接器,只需在感測器達到其使用壽命時進行處理。橫河電機的SENCOM 4.0平台,可降低營運成本和資源浪費,同時貢獻永續未來的長期業務目標。
-
pH和ORP傳感器
pH電極和傳感器是進行pH值測量的傳感部分,有伸縮式、流通式、浸入式和直插式等多種安裝選項。選擇合適的pH電極/傳感器對優化測量結果至關重要。