Introduction
In limestone-gypsum FGD (flue gas desulfurization) systems, online pH analyzers are used to control the consumption of a desulfurization agent (lime). The heavy lime scaling on the pH electrode is of great concern in the pH measurement. Frequent cleaning of the electrodes with acid is required to ensure accurate measurements, adding to the maintenance workload and cost. The SENCOM technology provides predictive maintenance, and FU20-FTS can withstand the harsh conditions of the scrubber. SENCOM™ features real-time diagnostics, sensor wellness for early detection of sensor failure and replacement, and proactive maintenance. So it saves both time and expense and, at the same time, ensures precise pH measurement over long periods.
Expected Benefits
– Improves the efficiency of a limestone-gypsum flue gas desulfurization system
– Ensures stable, continuous pH measurement
– Reduces operating costs
– Provides predictive maintenance
Process Overview
The limestone-gypsum flue gas desulfurization consists of two processes: absorption and oxidation.
Absorption process
Reaction formula; Ca(OH)2 + CO2 -> CaCO3 + H2O, 2CaCO3 + 2SO2 + 1/2H2O -> 2CaSO3·1/2H2O + CO2
In this process, it is crucial to promote the reaction of calcium (Ca) and to achieve a target desulfurization rate. The liquid’s pH, concentration, temperature, and liquid/gas ratio affect the absorption rate. When the pH of the absorbing solution is below 5, calcium hydrogen sulfite (Ca(HSO3)2) is generated. Ca(HSO3)2 is converted into sulfur dioxide (SO2) in a reversible reaction, lowering the desulfurization rate. When the pH of the absorbing solution is 7 or higher, carbon dioxide (CO2) in the flue gas reacts with calcium (Ca) to produce calcium carbonate (CaCO3). This increases lime consumption. Since pH influences the subsequent oxidation process, the pH of the absorbing solution should be kept between 5 and 6.
Oxidation process
Reaction formula: CaSO3·1/2H2O + 1/2O2 + Aq -> CaSO4·1/2H2O + Aq
In this process, calcium sulfite (CaSO3·1/2H2O) from the absorption process is oxidized with air to calcium sulfate (CaSO4) under about 500 kPa pressure and 50 to 80 °C temperature. The pH of the absorbing solution in the absorber is around 6. It should be kept at about 4 by adding acid from the cooling tower.
Solution Details
Deposits of crystalline substances (e.g., CaCO3) on electrodes in limestone-gypsum flue gas desulfurization systems decrease the accuracy of pH measurements. Because of the design of FU20 sensors, the lifetime of the sensors will be higher. And also, cleaning the electrodes and reducing maintenance time and cost are key points to consider when selecting a pH analyzer for the system. /HCNF option of FU20 sensors for cleaning can be suggested for easy maintenance. Acid cleaning is done with a 5% hydrochloric acid solution.
Product Recommendation
Transmitter
FLXA202 /FLXA21 2-wire pH/ORP measurement system; General purpose, Intrinsic safety
FLXA402 4-wire pH/ORP measurement system; General purpose
SENCOM™ Smart Adapter (optional)
The reusable smart adapter, SA11, offers full measuring parameter functionality of analog sensors equipped with a Variopin connector and Yokogawa ID chip. The SA11 automatically recognizes the installed sensor and prepares the proper configuration. SENCOM™ technology allows sensors to transmit and receive data when connected to a transmitter/analyzer or a PC. The SMART digital sensors maintain specific measurement and calibration data on an integrated chip that is an integral part of the sensor, providing easy plug-and-play solutions.
Sensor
Option 1: FU20-FTS Differential pH/ORP sensor
Differential sensor technology is unique to the industry. In this type of sensor, the reference cell is made of glass with no porous junction. No electrolyte is in contact with the process, ensuring a stable measurement and virtually maintenance-free. These sensors are intended for inline aggressive and harsh process control applications with some sodium content.
Key Features:
1. Extended sensor lifetime
2. Less maintenance requirement
3. No electrolyte depletion
4. Unaffected by the pressure changes
5. Less reliance on pH-regulating chemicals
*Calibration of differential pH sensors: A differential pH sensor needs pH buffers with the same ionic strength as the sodium reference because the sodium reference will change as the ionic strength changes. Yokogawa can supply these specific pH buffers, please check spare parts at GS 12B06J03-05EN-P
Option 2: FU20-NPT pH/ORP Combination sensor
The FU20 combination sensor shows how Yokogawa applies the motto “Simply the best” to sensor technology. The wide body sensors (26 mm diameter) hold four unique elements in one unbreakable PPS40GF (RytonTM) or PVDF body. Installation is simple with the integrated industrial 3/4” tapered thread. The large volume of gelled electrolyte and the double junction reference system slow down depletion and poisoning, extending the lifetime. The system is targeted at those applications where simplicity will result in accurate and reliable pH- or redox measurements. This sensor will be an excellent choice in 90% of the known applications.
Configurations
相關產品&解決方案
-
FU20/FU24/PH20一體化pH/ORP (REDOX)傳感器
PH20/FU20/FU24一體化pH/ORP傳感器體現了橫河電機如何將“簡單即好”這句格言應用於傳感器技術。
-
兩線式Dual Channel分析儀 FLXA21
FLEXA™ 系列分析儀用於工業裝定的連續線上測量,具有單感測器或雙感測器測量選項,是目前最靈活的兩線式分析儀。
-
兩線式液體分析計FLXA202
FLEXA™ 系列分析儀用於工業裝定的連續線上測量,具有單感測器或雙感測器測量選項,是目前最靈活的兩線式分析儀。
-
四線式液體分析計 FLXA402
The FLEXA™ 系列分析計是模組化設計的分析計,用於工業裝定中的連續線上測量。提供單一或多sensor測量。
-
數位 SMART SENCOM™ 轉接器: SA11
可重複使用的 SMART 轉接器,只需在感測器達到其使用壽命時進行處理。橫河電機的SENCOM 4.0平台,可降低營運成本和資源浪費,同時貢獻永續未來的長期業務目標。
-
pH和ORP傳感器
pH電極和傳感器是進行pH值測量的傳感部分,有伸縮式、流通式、浸入式和直插式等多種安裝選項。選擇合適的pH電極/傳感器對優化測量結果至關重要。