Introduction
The structures and functions of cells produced through spheroid formation are known to be more similar to live bodies than monolayer 2D organisms. Therefore, various formation methods and data accumulation for spheroids is progressing. We imaged spheroids using CellVoyager CV7000, and analyzed the images. Specifically, multiple images were captured along the Z-axis, reorganized into 2D image data*, and evaluated with regard to the maximum spheroid diameter and number of contained cells. In this way, combination of the CV7000 high-speed 3D imaging and projection functions facilitates the efficient analysis of 3D samples. Furthermore, the method can be applied to live cells to establish new experimental methods such as the time series evaluation of cells.
※Reorganized using the maximum intensity projection (MIP) function.
Fig. 1 (a): Original image
12 images were taken at 10 µm intervals in the Z-axis direction and displayed using MIP (a’) is the magnified section.
Large image
Fig. 1 (b): Recognition image
Spheroid contour (purple) and contained cells (blue) in image (a) recognized using analysis software (b’) is the magnified section.
Large image
Fig. 2(a): Tile image(25 tiles) of the entire well including 50-pixel overlapping regions between adjacent tiles in the XY direction
Large image
Fig. 2(b): Image created by combining the tile images in (a)
Large image
Experimental
- HeLa cells, in which Azami-Green was expressed, were inoculated in spheroid formation dishes (EZSPHERE®, AGC Techno Glass Co., Ltd.) (5×105 cells/dish) and cultured for seven days.
- Spheroids were collected, fixed, and inoculated again on 96-well plates. Images were captured using the CV7000 under the following conditions:
・Magnification: 10x (dry)
・Wavelength: 488nm
・Exposure time: 250msec
・12 images taken at 10µm intervals in the Z-axis direction over a distance of 110µm
・Images captured per plate: 25
(The entire well was captured using the tile function; time required per well was approx. 1.5 minutes.) - The maximum spheroid diameters and the number of contained cells in the MIP image were measured using the analysis software, and graphs were created using Spotfire®.
Results and Conclusion
EZSPHERE® has fine pores on the cultivation surface, which is coated with a special polymer that is non-adhesive for cells. Inoculated cells, therefore, form uniform spheroids in the wells. Six types of dishes with wells of different diameters and depths (4,000-900, -901, -902, -903, -904, -905) were used to form spheroids, and images were captured and analyzed using the CV7000. As a result, the data obtained for the maximum spheroid diameters and the number of contained cells correlated with the sizes of spheroids predicted from the diameters and depths of the wells. In this way, the CV7000 allows for efficient evaluation even for 3D samples such as spheroids.
Fig. 4 (a): Tile image of each well (numbers in the images are the model numbers of used dishes.)
900 (diameter: 500µm/ depth: 100µm), 901 (diameter: 200µm/ depth: 100µm)
902 (diameter: 500µm/ depth: 200µm), 903 (diameter: 800µm/ depth: 300µm)
904 (diameter: 800µm/ depth: 400µm), 905 (diameter: 1,400µm/ depth: 600µm)
Fig. 4 (b): Spheroid diameter
Fig. 4 (c): (c) Number of contained cells
Spotfire® is a registered trademark of TIBCO Software Inc.
Our Social Medias
We post our information to the following SNSs. Please follow us.
Follow us | Share our application | |
@Yokogawa_LS | Share on Twitter | |
Yokogawa Life Science | Share on Facebook | |
Yokogawa Life Science | Share on LinkedIn |
Yokogawa's Official Social Media Account List
ilgili Ürünler & Çözümler
-
Benchtop CQ1 Confocal System
The CellVoyager CQ1 provides the highest quality confocal images and extended live-cell imaging in a space-saving benchtop design.
-
CellPathfinder
CellPathfinder is designed for our HCA systems, CQ1 and the CellVoyager series. From beginners to experts, the analysis software lets you quantify subtle physiological changes and even label-free samples with various graph options.
-
CV8000 High-Throughput System
CellVoyager CV8000 is the most advanced high-content screening system. The improved built-in incubator lets you analyze extended live cell responses. With its expandability, 4 cameras, 5 lasers and an optional built-in pipettor, the system permits increasingly complex assay development and high-content screening.
-
High Content Analysis CellVoyager
Our high-content analysis (HCA) systems utilize powerful software to address a wide range of research applications from basic science to complex compound screening.
-
Life Science
Yokogawa’s sensitivity and precision solutions enable rapid and accurate measurements, empowering groundbreaking research, accelerating drug discovery, and optimizing bio-production at scale.