Introduction:
Wastes have been considered to be a serious worldwide environmental problem in recent years. Because of increasing pollution, these wastes should be treated. However, industrial wastes can contain a number of valuable organic components. Recovery of these components is important economically. Using conventional distillation techniques, the separation of acetic acid and water is both impractical and uneconomical, because it often requires large number of trays and a high reflux ratio. In practice special techniques are used depending on the concentration of acetic acid.
Between 30 and 70% (w/w) acetic acid contents, extractive distillation was suggested. Extractive distillation is a multicomponent-rectification method similar in purpose to azeotropic distillation. In extractive distillation, to a binary mixture which is difficult or impossible to separate by ordinary means, a third component termed an entrainer is added which alters the relative volatility of the original constituents, thus permitting the separation. In our department acetic acid is used as a solvent during the obtaining of cobalt(III) acetate from cobalt(II) acetate by an electrochemical method.
After the operation, the remaining waste contains acetic acid. In this work, acetic acid which has been found in this waste was recovered by extractive distillation. Adiponitrile and sulfolane were used as high boiling solvents and the effects of solvent feed rate/solution feed rate ratio and type were investigated. According to the experimental results, it was seem that the recovery of acetic acid from waste streams is possible by extractive distillation.
There are many methods available for the separation of acetic acid like, solvent extraction, distillation, adsorption, pervaporation and ion exchange.
Why pH is important?
If we take one of the separation technique as an example say using liquid membrane for separation. The vegetable oil being hydrophobic in nature allows the selective transport of acetic acid through it from the feed phase to the strip phase. Acetic acid is transported across the membrane from the feed phase in its unionized molecular form and not in its ionic form that is acetate. This required that the pH of the feed phase is lower than the pKa value of acetic acid which is 4.76 (at 25 degC). At pH above 4.76 acetate ion is formed, which cannot be permeate through the liquid membrane.
The pH value of the feed phases of 0.1 M, 0.05 M and 0.01 M concentrations of acetic acid was found to be 3.23, 3.65 and 4.05 respectively. These pH values are lower than the pKa value of acetic acid, enabling permeation of acetic acid across the membrane.
Critical area: Pure acetic acid service, which will have low conductivity. Acetic acid (systematically named ethanoic acid is an organic compound with the chemical formula CH3COOH (also written as CH3CO2H or C2H4O2). It is a colorless liquid that when undiluted is also called glacial acetic acid. Acetic acid has a distinctive sour taste and pungent smell. Although it is classified as a weak acid, concentrated acetic acid is corrosive. Acetic acid is the second simplest carboxylic acid (the simplest is formic acid) and is an important chemical reagent and industrial chemical.
Typical process details:
Pure acetic acid service, more than 30%
Water even less than <1%.
Typical problems:
The acid has very low conductivity so measurement is difficult.
Remedies:
To use a flowing special sensor to get a good electrolytical contact between reference cell and process.
Product Recommendations
Measurement System
Process Liquid Analyzer:
- 2-Wire Analyzer FLXA202
Dual sensor measurement on 2-wire type analyser
Redundant system on dual sensor measurement
Easy touch screen operation on 2-wire type analyzer
- 4-Wire Converter FLXA402
Connectable to upto five sensor
Easily viawable color LCD
Touch screen operation
Sensor Selection:
Yokogawa sensor SC21C-AGC55 can be the solution.
This flowing electrolyte sensors uses a ceramic reference junction, with the electrolyte (3.3 molal KCl). The flow of electrolyte through the junction, while small, remains the safest way to prevent clogging and to protect the internal reference against poisoning and diffusion.
Features for type SC21C-AGC55
- For tough application where pollution of the reference system is to be expected
- Low ionic application where the positive flow of electrolyte provides the conductivity needed to measure pH(< 50 µS/cm)
- Heavy duty pH sensitive glass.
- Flowing reference system for pollution resistance, and highly stable reference potential.
- Use in combination with the presurisable electrolyte reservoir to obtain a positive flow towards the process (K1500YA)
Temperature Sensor
SM60-T1 SERIES - For accurate pH measurement temperature compensation is required. Either a Pt100 or a Pt 1000 temperature electrode can be selected.
Cables used:
WU20-LT** Qty1 + WU20-PC** Qty1
Flow fitting:
F*20 various type of flow fittings can be used
Tangible benefit
Save down time in cleaning, repeated calibration, improve end product quality.
Note: For additional information on this application contact the local Yokogawa Process Liquid Analyzer Department
Industries
-
Petrochemical
Petrochemical companies’ needs are extremely diverse. To come out ahead in today’s highly competitive marketplace, producers are striving to improve quality and productivity. Yokogawa provides tailor-made solutions for these needs based on its long and wide-ranging experience in this field.
Related Products & Solutions
-
2-Wire Transmitter/Analyzer FLXA202
The FLEXA™ series analyzers are used for continuous on-line measurements in industrial installations. With an option for single or dual sensor measurement, they are the most flexible two-wire analyzer available.
-
2-Wire Transmitter/Analyzer FLXA21
The FLEXA™ series analyzers are used for continuous on-line measurements in industrial installations. With an option for single or dual sensor measurement, they are the most flexible two-wire analyzer available.
-
Digital SMART SENCOM™ Adapter, SA11
Reusable SMART adapter, requiring only the analog sensor to be disposed of when it reaches the end of its lifetime. With the SENCOM 4.0 platform, Yokogawa delivers reduced costs and waste while contributing to its long-term business goals of a sustainable future for all.
-
Flow/NPT Fittings FF20/FS20
Yokogawa has invested considerable design and development time in producing a full range of fittings with particular emphasis on designs that reduce installation and maintenance time and consequently save operation costs.
-
Industrial pH/ORP Electrodes
The heart of a pH measuring loop is the electrode system. Yokogawa has designed a wide range of electrodes to ensure this heart keeps beating under the most severe conditions.
-
Multi Channel 4-Wire Analyzer FLXA402
The FLEXA™ series analyzers are modular-designed analyzers used for continuous online measurements in industrial installations. They offer single or multi-sensor measurement.
-
pH and ORP Analyzers
pH and ORP meters, analyzers and transmitters are used for continuous process monitoring of pH and ORP to ensure water/product quality, monitor effluent discharge, batch neutralization, pulp stock, scrubbers, cooling towers, chemical, water/wastewater treatment and many other applications.
-
pH and ORP Sensors
pH electrodes and sensors are the sensing portions of a pH measurement. Various installation options including retractable, flow thru, immersion, and direct insertion. Proper pH electrode/sensor selection is critical for optimal measurement results.