JUXTA M Series for Unified Signals

M Series unified signal converters are plug-in type signal conditioners for common instrumentation signals. They have an I/O signal range of 4 to 20 mA DC or 1 to 5 V DC.

Details

The M Series bring Yokogawa performance and reliability to the popular plug-in style. Using industry standard pin configurations, anyone can upgrade to JUXTA performance by just plugging one in. The M Series signal conditioners for unified signals are applicable to the unified input/output signal applications for cost saving design.

  • For 4 to 20 mA DC or 1 to 5 V DC unified input/output signal applications.
  • Designed for 2000 VAC of high withstand voltage.
  • Two isolated outputs (MA7D and MH7D).
  • Plug-in type construction Easy for instrumentation planning, field wiring and maintenance because of its flexible insertion/extraction and ability to be pre-wired.
Construction Plug-in type (Main unit with Socket)
Mounting Method: Wall mounting or DIN-rail mounting
Connection Method: M3.5 screw terminal
External Dimensions: Model MH7, MA7, MCT7, MPT7: 85×50×123 mm (H×W×D)
Model MH7D, MA7D: 85×50×132 mm (H×W×D)
Power Requirements: 24 V DC±10% , 85 to 132 V AC / 85 to 150 V DC or 170 to 264 V AC

 

Signal Conditioners

Model Product Name Input Type Output Type Descriptions
MA7 Distributor (Unified Signal Type) 4 to 20 mA DC, from 2-wire type transmitter 1 to 5 V DC or 4 to 20 mA DC  
MA7D Distributor (2-output, Unified Signal Type) Isolated 2 outputs
MCT7 CT Converter(RMS) 0 to 1 A or 0 to 5 A AC 4 to 20 mA DC or 1 to 5 V DC  
MH7 Isolator (Unified Signal Type) 1 to 5 V DC or 4 to 20 mA DC 1 to 5 V DC or 4 to 20 mA DC  
MH7D Dual Outputs Isolator (Unified Signal, 2-output Type) Isolated 2 outputs
MPT7 PT Converter(RMS) 0 to 110 V AC, 0 to 150 V AC or 0 to 300 VAC 4 to 20 mA DC or 1 to 5 V DC  
  • List of RoHS

    This is a list of recorder and controller products that support the RoHS (2011/65/EU) directive.

    See More

Resources

Differential pressure: choose the MXT-R or WTXx-R computing unit. Vortex: choose the MXT-T or WXTx-T computing unit.
Do any models support ASTEM correction?
(ns-faq-juxta-11026-select)
None support it completely, but if you can identify the fuel type you can use an MTX-A user program. When changing the type, change the correction curve.
Overview:

None support it completely, but if you can identify the fuel type you can use an MTX-A user program. When changing the type, change the correction curve.

The model numbers are as follows. 8-pin: A1653MR 11-pin: 1654MR 15-pin: A1681MR (Please consult with your dealer at the time of purchase.)
Yes, with front panel keys.
Can I replace MA1 style A with style C?
(ns-faq-juxta-11044-spec)
Yes. We have improved functions such as raising the withstand voltage, adding a power supply indicator, and reducing the power consumption.
Yes, with a handy terminal or VJ77. Under D:SET, change D49:OUT1DR = DIRECT to REVERSE.
Check whether the key lock is engaged. If LOC = 1 or 2, set LOC = 0 with the SET/ENTER key, then enter setup parameters while LOC = -1.
Usually these are in the orifice specifications. Depending on the product, it may be listed with the normal operating pressure and temperature.
Not necessarily. The socket itself can be reused, but the terminal arrangement may differ depending on the specifications. Check the switch on the back of the MA1W to determine whether power is supplied to the transmitter. If the switch for supply of...
It holds the switching side immediately before the power went OFF.
Yes, there is the MH5 with 1 output and the MH5D with 2 outputs.
Use a communication cable with a 3-pin connector (F9182ED).
The open collector needs a power supply. Use one within the maximum allowable load. ...
Can I change the burnout operation?
(ns-faq-juxta-11001-spec)
This is possible if it is a microprocessor type converter. You will need a handy terminal to make the change. (VJR6, VJT6, VJS2, MR6, MT6, MS2, and others cannot be changed.)
F and W series: dedicated 3-pin cable D series: dedicated 5-pin cable VJ, J, and M series computation unit: 5-pin cable + modular conversion (E9786WH, sold separately).
If it is a model that allows range changes, it is possible just like from a JHT200. However, the type of cable is different from the one that comes standard, so you will need to purchase another cable. 3-pin cable: model F9182ED 5-pin cable: model F9...
Can I change the range on the MQ0?
(ns-faq-juxta-11004-spec)
No, you can't change the range after purchase. The compact VJQ7 model does allow you to change ranges, but this requires a setting tool that is sold separately.
How do I change settings?
(ns-faq-juxta-11006-setting)
Using the following settings tool, you can change the settings listed in the user's manual that came with the conditioner. Handy Terminals JHT-100 and JHT-200 BRAIN terminal BT200 (requires cable, sold separately) VJ77 Parameter Setting Tool...
What are the merits of plugin conditioners?
(ns-faq-juxta-11007-select)
They have the following advantages: Because you can separate the conditioner from the socket, panel work can proceed even without the conditioner. You can remove or replace the conditioner simply by plugging a new one in, so maintenance is easy. ...
The resistance is 250 Ω (4–20 mADC). However some computing units also have 100 Ω input.
You specify it for current pulse input. The resistance you specify depends on the specifications of the transmitter (mainly the rated current of the open collector). The internal load resistances are 200 Ω, 500 Ω, and 1 kΩ, and 0.5 ...
For example, if the specification of the open collector on the output side is 30 V/30 mA, use an internal load resistance of 1 kΩ (with a 24 V transmitter power supply). This results in a 0/24 mA current pulse.
IPTS-68: This is an international standard from 1968 where R100/R0=1.3850 that was used by the JIS from 1989 to 1997, but currently it is not in use. ITS90: An international standard from 1990 where R100/R0=1.3851, and used by the JIS from 1997 to th...
The input impedance of typical voltage input type instruments is 1 MΩ. By contrast, the allowable load impedance for voltage output is 2 kΩ or more, therefore the maximum number of units that can be connected is 500.
The input impedance of typical current input type instruments is 250 MΩ. By contrast, the allowable load impedance for current output is 750 kΩ or more, therefore the maximum number of units that can be connected is 3.
What does response speed **ms(10-90%) mean?
(ns-faq-juxta-11019-other)
It means the time until the output reaches 63% when input is applied in 10 Ω 90% steps.
A 90% response time is equivalent to 2.3 times the duration of a 63% response time.
What does "time constant" mean?
(ns-faq-juxta-11021-term)
In the case of conditioners, time constant reflects the response speed. In terms of a transfer function, it is expressed as OUT=INΩ(1-e EXP(-t/T)). OUT: output, IN: input, e: natural log, T: time constant, t: elapsed time When the elapsed time...
The total resistance ≥ zero side resistance + span resistance.
What is the output on burnout?
(ns-faq-juxta-11023-spec)
When UP, 106% of the output range or more; when DOWN, -6% or less.
What happens on a "burnout OFF"?
(ns-faq-juxta-11024-spec)
When input is interrupted it reaches ±OVER, but which of these is uncertain.
The F series has 30 steps. The W series has 40 steps. The M/VJ series has 59 steps.
On the M series you can select 50, 100, or 200 ms. On the F, W, and VJ series you can select 100 or 200 ms. (The VJXS can support 50 ms.)
It is with plug-in types. It is also sold separately.
Using a first-order lag or moving average computing unit helps suppress noise. You can use the following for this: M series plug-in type signal conditioners, VJ series compact plug-in type units, or F/W series front panel terminal type computing unit...
You can do this with a limiter or broken-line approximation function. You can use the following for this: M series plug-in type signal conditioners, VJ series compact plug-in type units, or F/W series front panel terminal type computing units. The br...
As the orientation affects heat dissemination, it cannot be horizontal.
JUXTA VJ series is not a CCC standard scope. Some models of the VJ series have acquired GB standard and can be used in China. Please contact us for applicable models. ...
Yes. Wire it without using the included resistor.
Short with a 250 Ω resistor (rated power of 0.25 W or more). If you don't have a resistor, a simple short is fine.
Check the power supply wiring. Check whether the power supply voltage meets the specifications. Check the polarity of the input wiring. Use a tester to measure the input terminal voltage. For current input specifications, confirm that the acces...
Check the power supply wiring. Check whether the power supply voltage meets the specifications. Check the polarity of the input wiring. Measure the voltage between the input terminal (-) and COM. The normal range is 1–5 VDC. Measure the v...
Check the power supply wiring. Check whether the power supply voltage meets the specifications. Confirm that the accessory RJC sensor is connected to the input terminal. Short the input terminals, then confirm that the output is equivalent to th...
Check the power supply wiring. Check whether the power supply voltage meets the specifications. For Pt100 input specifications, connect a 100 Ω resistance between input terminals A and B, short the B terminals, then confirm that the output ...
Check the power supply wiring. Check whether the power supply voltage meets the specifications. Check the polarity of the input wiring. Check the pulse specifications of the other instruments. For voltage pulse, open collector, and non-voltage ...
Check the power supply wiring. Check whether the power supply voltage meets the specifications. Check the polarity (+), (-) of the input wiring. Use a tester to measure the input terminal voltage. For current input specifications (applies to the...
Check the power supply wiring. Check whether the power supply voltage meets the specifications. Check the polarity of the input wiring. Check the pulse specifications of the other instrument. For voltage pulse, open collector, and non-voltage c...
Resistors come with isolators that have terminal block format current input specifications. Please attach it to the input terminals before use.
Yes. To satisfy the performance specifications, you should power the unit for 10–15 minutes.
See “Preventive Maintenance of Signal Conditioners” in TI 77J00B01-01.
PCBs were banned from manufacturing and imports in 1975. JUXTA was first released in 1987, therefore they should not include PCBs.
You can download these items from the Partner Portal member site *Log-in Required. You must register (free) to use Partner Portal.
What does span mean?
(ns-faq-juxta-20029-term)
Span means width, and is the width of the setting range.
Yes, the following can be mounted on DIN rails. VJ series M series F series W series
A thermocouple welds one end of two dissimilar metals and measures the thermoelectromotive force from a converter terminal. The thermocouple output voltage is affected by the temperature at both ends, so you must measure the temperature of the termin...
Allowable conduction resistance is resistance that can be used for the conductor between the input side instrument and the input terminal of the signal conditioner.
What is a thermocouple (TC?)
(ns-faq-juxta-20073-term)
A thermocouple (TC) is a temperature sensor based on the principle that an electric current is generated when a temperature difference is applied to a closed circuit created by putting together two metals of different types. (ThermoCouple)

Downloads

Looking for more information on our people, technology and solutions?

Contact Us

Top