The following shows conditions that can be changed during the hold operation
Segment setting method(SEG.T) | Segment time setting | Segment ramp-rate setting | ||
---|---|---|---|---|
Segment condition | Soak | Ramp | Soak | Ramp |
Hold SP | ✔ | ✔ | N/A | N/A |
Final target setpoint | ✔ | ✔ | N/A | N/A |
Remaining segment-time | ✔ | ✔ | ✔ | N/A |
✔:Available、N/A:Not available
If you first place it in a Hold status, you can use key operations to change the target setpoint (TSP) and remaining time (R.TIM). However these changes are only temporary. Some conditions apply for the changes.
Productos y Soluciones Relacionadas
-
UP35A/UP32A
The UP35A is a program controller with available 4 patterns and 40 segments (max.) and multi-channel contact I/O. It also includes a ladder sequence function. The UP32A is a compact program controller with up to 4 patterns and 40 segments available. It also includes a ladder sequence function.
-
UP55A
The UP55A is a newly-released 1/4 DIN sized program controller provides up to 30 program patterns, and simultaneous monitoring of 8 PV events, 16 time events, and 8 alarms. Also a ladder sequence function is included as standard.