Installation cost is reduced with a multi-variable transmitter. The EJX multi-variable transmitter combines three process variables in one transmitter. It removes the need to install a separate gauge pressure transmitter, temperature transmitter and flow computer. Dedicated software for configuring the flow calculation is available (FieldMate – Flow Navigator).
Customer Issues
- Installation cost of multiple field devices is high.
- Mass flow measurement is expensive.
Utilize EJX910A/930A + Flow Navigator
- From one multi-variable transmitter, you can measure differential pressure, static pressure, temperature and mass flow. The total cost is greatly reduced.
- Flow Navigator software provides a simple, user friendly method to configure the mass flow measurement.
Utilize FieldMate
- Flow Navigator has a step by step interface based on FDT/DTM technology. You can set the data by simply selecting the primary element, and inputting the flow rate information.
- You can copy the configuration of one transmitter to another transmitter to help with multiple configurations.
EJX Multi-Variable Transmitter Outputs
① In the case of HART digital / FOUNDATION Fieldbus /Modbus, these types of outputs can transmit multi process values at the same time.
② In the case of Analog signal (4-20mA), a multiplexer can be used to convert up to three values from HART signals into 4-20mA signals. The transmitter can transmit up to four values in conjunction with the original signal.
③ In the case of ISA100(wireless), the ISA 100 adaptor can transmit up to four values from the HART signal without reconstructing an existing line.
The measurements that EJX multi-variable transmitter can transmit
Protocol |
DP | SP |
Ext. TEMP |
Other TEMP |
FLOW |
Total Flow *4 |
---|---|---|---|---|---|---|
HART *1 | ● | ● either H or L |
● | ● Capsule Amplifier Flange (/DG6) |
● | ● |
FOUNDATION Fieldbus *2 | ● | ● either H or L, or both |
● | ● Capsule Amplifier Flange (/DG1) |
● | ● |
Modbus *3 |
● | ● either H or L |
● | ● Capsule Amplifier |
- | - |
*1:In 4-20mA, output is one signal by one value。In HART, output is one signal by multiple value (up to four value).
*2:Number of output values is up to five.
*3:Flow, total flow, other temperature(flange)as output are not supported.
*4:Total flow is using HART or the pulse signal. 4-20mA signal is not supported. In FOUNDATION fieldbus, output is using IT function block.
Productos y Soluciones Relacionadas
-
EJX910A
This transmitter precisely measures differential pressure, static pressure, and process temperature; then uses these values in a high-perfomance on-board flow computer to deliver fully compensated Mass Flow.
-
EJX930A
Designed specifically for high static pressure applications, this transmitter precisely measures differential pressure, static pressure, and process temperature; then uses these values in a high-perfomance on-board flow computer to deliver fully compensated Mass Flow.
-
FSA120 Flow Configuration Software FlowNavigator
FlowNavigator (FSA120) is a unique software tool that helps you get the most out of the EJX910A / EJX930A Multivariable Transmitter by supporting the configuration of the discharge coefficient, primary device bore, upstream internal pipe diameter, gas expansion factor, density, and viscosity data needed to perform full compensation and dynamic calculation of the mass flow.
-
Mobile Field Device Management FieldMate
FieldMate 3.0 is a PC based tool that enables you to see intelligent field devices clearly, know their condition in advance, and act with agility throughout maintenance work flow.