YS80 Series Rack Instruments

The Style R and Style S models have completely interchangeable I/O specifications, terminal arrays, and shapes. They can be replaced with the latest devices just by replacing the internal instruments, leaving the wiring intact.

*Remarks
The sales area is limited to the countries where do not require safety standards CE, KC, UL, and CSA.

Details

STED mV, Temperature and Potentiometer Converter (Style S)

STED mV, Temperature and Potentiometer Converter (Style S)

The Model STED Converter accepts a mV DC, thermo-couple, RTD or potentiometer signal, converts and normalizes it, provides isolation, and outputs 1 to 5 V DC and 4 to 20 mA DC signals. Two types are prepared for the STED converter: fixed input type that is fixed to mV DC, thermocouple, RTD or potentiometer, and universal input type that can select input type from mV DC, thermocouple or RTD. Burnout function is provided as standard for each type.

SKYD Alarm Unit (Style S)

SKYD Alarm Unit (Style S)

The Model SKYD Alarm Unit accepts input signals, and provides absolute or deviation alarm outputs. Absolute alarms are output after comparison of input signals from a single source with one or two setpoints, and deviation alarms are output after comparison of input signals from two sources with two setpoints. Direct or reverse alarm action can be selected for each of the alarm output settings. The front panel is provided with an alarm LED for confirming alarm relay operation (when relay is energized). The Model VJ77 PC-based Parameter Setting Tool is used for setting various parameters. On the SKYD model with display setter (SKYD- 04), input indication (engineering unit) and alarm settings can be set on the front panel.

SALD mV and Temperature Alarm Unit (Style S)

SALD mV and Temperature Alarm Unit (Style S)

The SALD mV and Temperature Alarm Unit accepts a mV DC, thermocouple or RTD input signal, compares the input signal with an alarm setpoint, and outputs an alarm signal. One or two absolute alarm outputs can be provided on one input. Direct/reverse action can also be set to each of the alarm setpoints. Alarm LED is provided on the front panel for confirming alarm relay action (when relay is energized). The Model VJ77 PC-based Parameter Setting Tool is used for setting various parameters. For the SALD with display setter (SALD- 4), input indication and alarm setpoints can be set on the front panel.

SDAU Digital Alarm Unit (Style R)

SDAU Digital Alarm Unit (Style R)

The SDAU Digital Alarm Unit accepts two input signals (freely selectable from 1 to 5 V, mV, thermocouple and RTD), and six alarm detecting results are freely connected to AND or to OR. Then they are output to alarm relays (two points for standard). Each alarm detecting section detects upper and lower limits of absolute value, rate-of-change and deviation. Either a normally energized or de-energized is selectable for alarm output relays. Four points of alarm output, RS485 communication function or retransmission output can be optionally equipped. The display setter on the front panel can show input values and set/change parameters such as an alarm setpoint. The Model VJ77 PC-based Parameter Setting Tool can also set/change parameters.

SIND Integrator (Style S)

SIND Integrator (Style S)

The SIND Integrator is a voltage-to-pulse converter that converts 1 to 5 V DC inputs to corresponding pulse frequency output. It can be used with a YS80 series SICD counter to totalize flow quantity. Two integrating modes are available: proportional integration that directly totalizes the input, and square root integration that totalizes square-root values. The Model VJ77 PC-based Parameter Setting Tool is used for setting various parameters. On the SIND model with display setter (SIND-x04), input indication (engineering unit) and alarm settings can be set on the front panel.

SISD Isolator (Style S)

SISD Isolator (Style S)

The Model SISD Isolator accepts a 1 to 5 V DC input signal. The input signal is isolated from the power supply common and from the Isolator output signal. There are two outputs: 1 to 5 V and 4 to 20 mA DC.

SDBT Distributor (Style S)

SDBT Distributor (Style S)

The Model SDBT Distributor supplies power to a two-wire transmitter and converts the 4 to 20 mA DC transmitter signal current to two 1 to 5 V DC and one 4 to 20 mA DC (for SDBT-21 type only) output signals. Isolation between input/output and distributor power supply is provided ("loop isolation"); isolation between input and output ("field isolation"); is specification. Current limiting (to protect against transmitter wiring short circuits) is provided, and a square root characteristic is optional.

SDBS Distributor (Style S)

SDBS Distributor (Style S)

The Model SDBS Distributor supplies power to a two-wire transmitter and converts the 4 to 20 mA DC transmitter signal current to two 1 to 5 V DC output signals. Isolation between input/output and distributor power supply is provided. Current limiting (to protect against transmitter wiring short circuits) is also provided.

Resurse

Prezentare generală:

Mercian uses the Part 11-compliant DX200P Paperless Recorder in its pharmaceutical manufacturing works.

Prezentare generală:
  • Emergency interlock circuits for petrochemical plants and other facilities must be independent of the main control system.
  • The YS80 Rack Instrument interfaces not only with field devices and upstream control systems, but also with emergency interlock circuits guarding against process abnormalities.

Downloads

Informații Tehnice

Videoclipuri

Prezentare generală a produsului
Prezentare generală:

The YSS1000 setting software (hereinafter referred to as the YSS1000) is package software to configure the functions of the YS1000 series (hereinafter referred to as the YS1000) devices. Writing and reading of parameters and user programs of the YS1000, and PID tuning and monitoring of user programs can be performed through the use of communication.

Cauți mai multe informații despre oamenii noștri, tehnologie și soluții?

Contactează-ne

Sus