The AXFA11 magnetic converter has been developed based on Yokogawa's decades long experience in magnetic flowmeters. The AXFA11 continues the tradition of high quality and reliability that has become synonymous with the Yokogawa name and in addition features an even higher level of performance and increased functionality.
Retaining all the features and functions of the Admag series of converters, in addition the AXFA11 offers an enhanced dual frequency excitation method as an option for difficult applications as well as new diagnostics to detect electrode coating. Combined with a flowtube utilizing the optional replaceable electrode design, the user benefits through the ability to schedule maintenance for reduced process downtime and in turn a lower total cost of ownership.
About OpreX
OpreX is the comprehensive brand for Yokogawa’s industrial automation (IA) and control business and stands for excellence in the related technology and solutions. It consists of categories and families under each category. This product belongs to the OpreX Field Instruments family that is aligned under the OpreX Measurement category.
Details
Specifications
AXF Remote Flowtube |
AXF Integral Flow meter |
AXFA14 Converter |
AXFA11 Converter |
|
---|---|---|---|---|
Size | 2.5 to 400 mm (0.1 to 16 inch) [depends on specifications] |
2.5 to 400 mm (0.1 to 16 inch) [depends on specifications] |
Combined with Remote type flowtube 2.5 to 400mm (0.1 to 16 inch) |
Combined with Remote type flowtube (Note) 2.5 to 1800 mm (0.1 to 16 inch) |
Type of Use | General-purpose use, Ex-proof type, Sanitary type, Submersible type |
General-purpose use, Ex-proof type, Sanitary type |
General-purpose use, Ex-proof type |
General-purpose use |
Fluid Temp. | -40 to 160 deg.C (-40 to 320 deg.F) [depends on specifications] |
-40 to 130 deg.C (-40 to 266 deg.F) [depends on specifications] |
- | - |
Ambient Temp. | -40 to 60 deg.C (-40 to 140 deg.F) [depends on model type] | |||
Accuracy | 0.35% of rate (Optional ; 0.2% of rate) | |||
Fluid Conductivity | 1 micro-S/cm or larger (depends on nominal pipe size and fluid condition) | |||
Lining | Fluorocarbon PFA/Ceramics/Polyurethance Rubber/ Natural Soft Rubber [depends on model type] |
- | - | |
Process Connection | Wafer, Flange, Sanitary connections (Clamp[Tri-clamp, DIN, ISO], Union thread[DIN, ISO SMS], Butt-weld), etc. |
- | - | |
Maximum Cable Length | - | - | 100m (330 ft) | 200m (660 ft) |
Indicator | - | Multi line backlit LCD (Full dot-matrix) | ||
Diagnosis | Adhesion diagnosis, Empty pipe, Coil open, etc. | |||
Alarm message | Alarm message with corrective measures is indicated (English, German, French, Italian, Spanish, Japanese) | |||
Excitation method | Dual Frequency Excitation: AXF sizes 2.5 to 400 mm, Enhanced Dual Frequency Excitation (optional): AXF sizes 25 to 200 mm Pulsed DC Excitation: AXW sizes 500 to 1800 mm (Note) |
|||
Ex-proof type | ATEX, FM, CSA, IECEx, TIIS | - | ||
Options | Replaceable electrode, Rotatable terminal box(converter), Mirror finished lining surface(for PFA/Ceramics), Special gaskets, etc. |
Refer to GS sheet for details.
Note: AXFA11 Converter can be also combined with AXW Remote Flowtube.
Zasoby
Yokogawa Electric Corporation promotes the standardization of FOUNDATION™ fieldbus as the communication foundation supporting Asset Excellence for VigilantPlant, which is an approach aimed at the advancement of plant instruments and equipment. With the recent dramatic advancement of fieldbus technologies, information processing technologies, and network speed, it has become possible to process various kinds of information inside the field sensors and transmit the results to the distributed control system (DCS) and host computer.
Downloads
Broszury
- Magnetic Flowmeter ADMAG series (3.1 MB)
- ADMAG AXF Verification Tool (1.9 MB)
Instrukcje obsługi
- AXF Series Magnetic Flowmeter Installation Manual *See Manual Change 17-0016-E (7.2 MB)
- AXF Series Magnetic Flowmeter Installation Manual FOUNDATION Fieldbus Communication Type and PROFIBUS PA Communication Type (876 KB)
- AXFA11G Magnetic Flowmeter Remote Converter [Hardware/Software] (1.4 MB)
- AXF FOUNDATION Fieldbus Communication Type Magnetic Flowmeter (791 KB)
- AXF PROFIBUS PA Communication Type Magnetic Flowmeter (5.3 MB)
- AXF Verification Tool (10.7 MB)
- ManualChange17-0016-E (547 KB)
Ogólne specyfikacje
2D/3D Configurator
Szukasz dodatkowych informacji na temat naszych pracowników, technologii i rozwiązań?
Kontakt