FA-M3

The new FA-M3V series

The FA-M3 is designed and best known for its speed so it's only natural that the new series be named FA-M3V, where V stands for "Vitesse", which means speed in French.
From day one, FA-M3 has relentlessly pursued higher speeds as the most effective means to solving customer challenges.
Over time, this has evolved into the High Speed IPRS (Instruction, Processing, Response and Scan) design concept. Today, we have set a new record in this quadruple speed quest by creating the FA-M3V, which offers extensibility and reliability at incredible speed.    
FA-M3V, the leading edge controller for customers who will settle for nothing less than the world's best.

Delivering stable control at the highest speed

Featuring ultra high-speed, stable control, link functions and improved network performance, the FA-M3V controller is created by improving every aspect to deliver stable control at the highest speeds.

Stretching the "High-speed IPRS" Design Concept

FA-M3V is the industry's fastest PLC in terms of CPU scanning speed. This incredible speed is made possible by stretching the High-speed IPRS (Instruction, Processing, Response and Scanning) design concept of the FA-M3 family of controllers and harnessing two Yokogawa core technologies, namely, the Vitesse engine and the parallel instruction processing system (PIPS).

High-speed IPRS

 

 

The FA-M3 Vitesse Engine

Supreme ladder processing capability

Vitesse Engine

 

Parallel & Independent Processing System (PIPS)

Fast, stable control for high quality production

PIPS

Details

Enhanced High-speed IPRS (Instruction, Processing, Response and Scanning)

Quadruple speed quest based on the High-speed IPRS design concept

High-speed Instructions  -Unrivalled High-speed Processing-

3.75ns for basic instructions, 7.5ns for application instructions and 37.5ns for floating-point add instruction

Faster processing of basic instructions enables reduced tact time using faster equipment, supports high-speed networking, enhances operability, as well as supports fault diagnosis and other advanced functions. In addition, faster application instructions widen utility to more applications. Floating-point addition instructions can also be speeded up to meet the requirements of high-precision applications.

Enhanced High-speed IPRS

 

High-speed Processing  -Max out Equipment Capability by Tuning-

Sensor control function enables fast, constant scan from 100μs (10μs resolution when using SCB)

FA-M3V's sensor control function allows input, computation and output of one program block to be executed at constant intervals as short as 100μs, independently of the main scan, which may have a longer scan time due to advanced functionality of external devices.
The number of PLC units can be reduced since two ladder programs can be executed by one CPU module.

Enhanced High-speed IPRS

 

High-speed Response  -Instantaneous Response to Interrupts-

Interrupt response time of 85μs and digital filter from 0ms

With input response time of 85μs for interrupts from DC input modules, the FA-M3V can immediately respond to changes in inputs, enabling instantaneous high-speed control. Fast response (circuit delay 100μs min.) is achieved by focusing on total response time (input  program execution (processing)  output) and allowing variable time constants to be set to zero. Moreover, input response time of 10μs can be achieved with the use of a high-speed contact input module (F3XD16-3H).

Enhanced High-speed IPRS

 

High-speed Scan  -Slashing Tact Time and Improving Quality-

Scanning a 100K step ladder program in 1ms

The incredible speed of the FA-M3V of processing 100K ladder program steps within 1ms is achieved by analyzing its internal processes and striving for speed in every aspect. This translates into five times faster scanning for advanced device applications.
* The quoted scan time is achievable under certain conditions. Actual scan time may vary with program processing and system configuration.

Enhanced High-speed IPRS

Extended Functionality Coupled with Speed

Over and above fast, stable control, the FA-M3V delivers extended functionalities, including diverse network support, large file transfer and "PC-less" maintenance for improved productivity.

Truly Range-free Controllers

The FA-M3 family of controllers is consolidated into two new CPU models of 60K-step and 260K-step program size so picking your ideal CPU is easy!

Truly Range-free Controllers

 

Built-in Ethernet Network Support

Built-in Ethernet port for easy integration with manufacturing systems

Faster Ethernet Communication Processing

The built-in Ethernet port enables fast, stable communication. With a variety of functions condensed into an all-in-one CPU module, the FA-M3V offers cost advantages, a smaller footprint and networking that will not degrade control processing performance.

All-in-one module

 

Enhanced Integration with Higher-level Systems

Fast communication response is achieved without compromising stable control.
Scaling up to process large production data is simple.

  • Much higher Ethernet throughput
  • Large memory and SD memory card (SDHC compliant 32GB max.)
  • Cache registers (1MB max.)
  • Modbus/TCP Slave (server) function

Ethernet throughput comparison 

High Reliability Enables Stable Operation

High-precision calculation capability plus enhanced security with user management and operation log means even better reliability.

High Precision, High Reliability

Higher precision with more data digits, better reliability with built-in ECC

High-reliability Design for Reducing Failure Rate

SRAM Hardware Error Check and Correction (ECC)

  • Hardware error check and correction (ECC) for the program execution area (within ASIC and external SRAM)
  • ECC does not impair performance
  • Improved reliability through patrol check* (only for backup SRAM)

Hardware ECC 

Use of Flash Memory

  • Flash memory is used for storing programs. This minimizes the impact of memory data loss at power off.

Pursuit of Fundamental Reliability -Single board design-

  • Reducing the number of components fundamentally reduces the sources of failures.

High-precision Calculations

Operations preserving 32-bit significant digits -64-bit integer arithmetic-

  • No need to convert all the way to floating point data for calculation

Double-precision floating point operations

  • Built-in floating-point unit (FPU) for floating-point operations
  • No precision loss even if converted to floating-point data for calculations

Security

Safeguards important customer assets by preventing unauthorized copying and keeping an operation log.

User management function

Appropriate access permissions can be defined for administrator, service and user personnel so that better security and work efficiency can be achieved concurrently.

User management function

Operation log function

The operation log function keeps a historical log of operations performed on the CPU module. With the user authentication function, the user name of the person performing an operation can also be recorded.

Operation log function

FA-M3 Programming Tool WideField3

New, useful functional enhancements based on user requirements

Improving program development efficiency is a common concern of all PLCs. The latest FA-M3 Programming Tool WideField3 is designed to harness the incredible power and speed of the FA-M3V. Its new features include balloon comment and monitor for more convenient programming, as well as the cross reference and script functions for more efficient programming. Besides engineering support function is added for efficient debugging.

WideField3

FA-M3 Simulation Software Virtual-M3

Great performance for debugging and troubleshooting

The Virtual-M3 is a simulation software which runs ladder sequences on a PC and debugs programs without any real machine. The I/O module sumulation function, link function with HMI, step operation function, and link function with Live Logic Analyzer drastically reduce the debugging time.

Virtual-M3

 

Live Logic Analyzer function (for WideField3 R3.01 or later)

User-friendly engineering feature to leapfrog your debugging

The live logic analyzer stores the status and contents of devices designated for sampling in the trace buffer memory, as the sampling trace tool does, and immediately displays the trace results.
Trace results can be displayed in scan chart format while ladder program running high speed application concurrently.

 

Introduction Movie

 

Upgraded trace function by high-speed communication

  • Up to 96 data points (64 relays and 32 registers) can be traced concurrently.
    Large sampling capacity up to 1M samples per channel
  • Even advanced-function I/O devices can be traced.J53
  • Once started, trace result can be displayed anytime, allowing concurrent program debugging even during tracing.

Traces equal to actual production performance

  • Minimized trace execution impact on the CPU scan.
  • The trace runs with minimal impact on the CPU scan and thus reflects actual production performance.
  • USB and Ethernet peripheral processing run in parallel independently without affecting the CPU scan.

High degree of usability by powerful HMI

  • Easy registration, configuration and operation.
  • User marker enables pin-point search of massive trace data.
  • Zoom in on any trace area on the main window, split a window horizontally or vertically.

easy registration, configuration and operation 

no impact on CPU scan with parallel processing

 

Sampling Trace

Advanced analysis environment with oscilloscope-like view

The sampling trace function enables efficient debugging and timely troubleshooting.
The new version adds improved readability to advanced, flexible configuration, and introduces oscilloscope-like convenience functions including inter-point analysis, range zooming and filter configuration.

Sampling Trace

 

Various types of trace mode

  • Single trace
    This mode performs a sampling trace only once.
  • Multiple trace
    This mode performs multiple sampling traces successively.
    After one cycle of sampling is complete, the sampling trace functions output results to files and then automatically wait for the trigger  to occur. Therefore, you can successively sample data 100 times max.
  • Endless trace
    The single trace mode includes the method of continuing sampling until a user cancels the sampling trace if "no end conditions" is specified (endless trace), in addition to the method of ending sampling automatically if a trace end condition is met.                                

Tool-less trace
Tool-less trace function enables to store the result of tracing data without using sampling trace tool.
You can execute the trace with the card batch by using an SD card and with virtual directory commands. You can obtain sampling trace results via the SD card or through FTP file transfer.
After the results are stored in a personal computer, you can view them in WideField3.

 

Script Coding and Monitoring

Complex calculation processing made easy!

Computations and text manipulations can be programmed using script code, which is converted automatically into ladder code before execution. Moreover, used devices can be monitored within script code for efficient debugging, and mnemonics can be entered in script code for even more powerful programming!

Script Coding

FA-M3V Offers a Stress-free Solution

for all process challenges from development through maintenance.

Process Flow from Development through Maintenance

Starting right from CPU model selection all-the-way to maintenance after commissioning, the FA-M3V promises a stress-free experience by enabling development according to design and reducing development effort from ladder program design to engineering.

FA-M3_16

Hardware

     

Category Name Type name Specification
Base Base module F3BU04-0N For power supply (F3PU10/F3PU16) + 4 slots (CPU+I/O)
F3BU05-0D For power supply (F3PU20/F3PU30/F3PU26/F3PU36) + 5 slots (CPU+I/O)
F3BU06-0N For power supply (F3PU10/F3PU16) + 6 slots (CPU+I/O)
F3BU09-0N For power supply (F3PU20/F3PU30/F3PU26/F3PU36) + 9 slots (CPU+I/O)
F3BU13-0N For power supply (F3PU20/F3PU30/F3PU26/F3PU36) + 13 slots (CPU+I/O)
F3BU16-0N For power supply (F3PU20/F3PU30/F3PU26/F3PU36) + 16 slots (CPU+I/O)
Power supply Power supply module F3PU10-0S 100 to 240V AC, 5V DC/2.0A rated output (for 4 and 6 slots, M4 screws)
F3PU20-0S 100 to 240V AC, 5V DC/4.3A rated output (for 5, 9,13 and 16 slots, M4 screws)
F3PU30-0S 100 to 240V AC, 5V DC/6.0A rated output (for 5, 9,13 and 16 slots, M4 screws)
F3PU16-0S 24V DC, 5V DC/2.0A rated output (for 4 and 6 slots, M4 screws)
F3PU26-0S 24V DC, 5V DC/4.3A rated output (for 5, 9, 13 and 16 slots, M4 screws)
F3PU36-0S 24V DC, 5V DC/6.0A rated output (for 5, 9, 13 and 16 slots, M4 screws)
CPU Sequence CPU module F3SP22-0S Ladder 30K steps, basic instruction 0.045μs or longer, with memory*
F3SP71-4S Ladder 60K steps, basic instruction 0.00375μs or longer, with network and Modbus/TCP slave (server) functions (USB2.0, Ethernet)
F3SP76-7S Ladder 260K steps, basic instruction 0.00375μs or longer, with network and Modbus/TCP slave (server) functions (USB2.0, Ethernet)
Memory ROM pack RK33-0N Ladder 56K steps (for F3SP22)
RK73-0N Ladder 120K steps (for F3SP22)
Digital I/O Input module F3XA08-1N 100-120V AC, 8 points
F3XA08-2N 200-240V AC, 8 points 
F3XA16-1N 100-120V AC, 16 points 
F3XH04-3N High-speed input with pulse catch function, 24V DC, 4 points
F3XC08-0N No-voltage contact input, 8 points 
F3XC08-0C No-voltage contact input, 8 points, separate commons 
F3XD08-6F DC input, 12-24V DC, 8 points 
F3XD16-3F DC input, 24V DC, 16 points 
F3XD16-4F DC input, 12V DC, 16 points 
F3XD16-3H DC input, positive common, 24V DC, 16 points (high-speed input) 
F3XD32-3F DC input, 24V DC, 32 points 
F3XD32-4F DC input, 12V DC, 32 points 
F3XD32-5F TTL input, 5V DC, 32 points
F3XD64-3F DC input, 24V DC, 64 points
F3XD64-4F DC input, 12V DC, 64 points 
F3XD64-6M DC input, 12 to 24V DC, 64 points (8x8)
Pulse input module F3XS04-3N Ring-up counter, 0 to 20kHz, 24V DC input, 16-bit channel x 4 
F3XS04-4N Ring-up counter, 0 to 20kHz, 12V DC input, 16-bit channel x 4 
Output module F3YA08-2N Triac output (100 to 240V AC), 1 A, 8 points 
F3YC08-0C Relay output (5 to 24V DC, 100 to 240V AC), 2A, isolated commons, 8 points 
F3YC08-0N Relay output (5 to 24V DC, 100 to 240V AC), 2A, 8 points 
F3YC16-0N Relay output (5 to 24V DC, 100 to 240V AC), 2A, 16 points 
F3YD04-7N TR output, 24V DC, 2A, isolated commons, 4 points 
F3YD08-6A TR sink output, 12 to 24V DC, 1A, 8 points 
F3YD08-6B TR source output, 12 to 24V DC, 1A, 8 points
F3YD08-7A TR sink output, 12 to 24V DC, 2A, 8 points 
F3YD14-5A TR sink output, 12 to 24V DC, 0.5A, 14 points 
F3YD14-5B TR source output, 12 to 24V DC, 0.5A, 14 points 
F3YD32-1H High speed TR sink output, 12 to 24V DC, 0.1A, 32 points, with output short-circuit protection 
F3YD32-1P TR sink output, 12 to 24V DC, 0.1A, 32 points, with output short-circuit protection 
F3YD32-1R TR source output, 12 to 24V DC, 0.1A, 32 points, with output short-circuit protection
F3YD32-1T TTL output, 5V DC, 16mA, 32 points
F3YD64-1P TR sink output, 12 to 24V DC, 0.1A, 64 points, with output short-circuit protection
F3YD64-1R TR source output, 12 to 24V DC, 0.1A, 64 points, with output short-circuit protection
F3YD64-1M TR output, matrix scan, 12 to 24V DC, 64 points (8x8) 
I/O module F3WD64-3P DC Input, TR sink output, 0.1A, 24V DC, 32 points each, with output short-circuit protection
F3WD64-4P DC Input, TR sink output, 0.1A, 12V DC, 32 points each, with output short-circuit protection
Analog I/O Analog input module F3AD04-5V 0 to 5V DC,1 to 5V DC,-10 to 10V DC,0 to 10V DC, 4 points,12bitA/D Sampling period 1ms
F3AD04-5R 0 to 5V DC,1 to 5V DC,-10 to 10V DC,0 to 10V DC,Input 4 points,16bitA/D, Sampling period 50μs
F3AD08-5V 0 to 5V DC,1 to 5V DC,-10 to 10V DC,0 to 10V DC, 8 points,12bitA/D, Sampling period 1ms
F3AD08-4W 0 to 20mA,4 to 20mA, 8 points,12bitA/D, Sampling period 1ms
F3AD08-4R 0 to 20mA,4 to 20mA input, 8 points, 16-bit high-res. ADC, sampling at 50μs/point
F3AD08-5R 0 to 5V,0 to 10V,1 to 5V,-10 to 10V DC input, 8 points, 16-bit high res. ADC, sampling at 50μs/point 
F3AD08-6R 0 to 5V,1 to 5V,-10 to 10V DC,0 to 20mA,4 to 20mA input, 8 points, 16-bit high res. ADC, sampling at 50μs/point 
Analog output module F3DA04-6R -10 to 10V, 0 to 10V, 0 to 5V, 1 to 5V, 4 to 20mA, 0 to 20mA and -20 to 20mA DC output, 4 points,
16-bit high-res. DAC
F3DA08-5R -10 to 10V, 0 to 10V, 0 to 5V, 1 to 5V DC output, 8 points, 16-bit high-res. DAC
Temperature Temperature control and PID module F3CU04-0H 4 loops of universal input
Time-proportional PID output (open collector)
Single-slot size
/DF: with Fahrenheit display function
F3CU04-1H 4 loops of universal input and output
(open collector, continuous 4-20 mA output)
Single-slot size
/DF: with Fahrenheit display function
Temperature monitoring
module
F3CX04-0H 4 channels of universal input
Single-slot size
/DF: with Fahrenheit display function
Data acquisition High-speed data acquisition module F3HA06-1R -10 to 10V, 0 to 10V, 1 to 5V, -5V to 5V, -2.5 to 2.5V, input 6 points, 5μs, data buffer 2M words
F3HA12-1R -10 to 10V, 0 to 10V, 1 to 5V,-5V to 5V,-2.5 to 2.5V, input12 points, 5μs, data buffer 2M words
Communications Ethernet interface
module
F3LE01-1T 10Mbps, 10BASE-T, with higher-level link and event transmission functions 
F3LE11-1T 10/100Mbps, 10BASE-T/100BASE-TX, with E-mail function 
F3LE12-1T 10/100Mbps, 10BASE-T/100BASE-TX, with higher-level link, (UDP/IP)messaging function
NX Interface module F3NX01-2N 10/100Mbps, 10BASE-T/100BASE-TX, with Autonomous Distribution protocol
EtherNet/IP interface module F3LN01-0N 100Mbps, 10BASE-T/100Base-TX, EtherNet/IP scanner / adapter
FL-net interface module F3LX02-2N 10/100Mbps, 10BASE-T/100BASE-TX, FL-net (OPCN-2) ver.2.00
DeviceNet interface module F3LD01-0N 500kbps max., DeviceNet port x 1, with master/scanner function 
F3LD02-1N 500kbps max., DeviceNet port x 1, with slave/adapter function 
CAN2.0B Interface Module F3LD21-0N CAN2.0B format, 1channel, 1Mbps max 
Modbus Interface module F3LC31-2F Modbus RTU/A5SCII, 115kbps max, 1port 
GP-IB communications
module
F3GB01-0N GP-IB port x 1
Personal computer link module F3LC11-2F 115kbps max., RS-422/RS-485 port x 1
F3LC11-1F 115kbps max., RS-232-C port x 1, with modem interface function 
F3LC12-1F 115kbps max., RS-232-C port x 2, with modem interface function 
Ladder communications
module
F3RZ81-0F 115kbps max., RS-232C port x 1
F3RZ82-0F 115kbps max., RS-232C port x 2 
F3RZ91-0F 115kbps max., RS-422/RS-485 port x 1
UT link module F3LC51-2N RS-422 / RS-485 port x 1, allows easy connection of digital indicating controller 
FA link H2 module F3LP32-0N 32 stations max., total transmission distance 1km, 1.25Mbps max.
Remote I/O YHLS master module F3LH01-1N 12Mbps max., YHLS port x 1 
F3LH02-1N 12Mbps max., YHLS port x 2
Fiber-optic FA-bus module F3LR01-0N 7 stations max., total transmission distance 200m, 10Mbps max.
Fiber-optic FA-bus Type 2 F3LR02-0N 32 stations max., total transmission distance 1.4km, max. distance betw. stations 500m, 10Mbps max. 
FA-bus Type 2 module  F3LR02-1W 7 stations max., max. transmission distance: 70m for daisy-chain configuration and 80m for loop configuration, max. distance between stations 10m, 10Mbps max., wired 
Counter/
positioning
High-speed counter
module
F3XP01-0H Up/down counter, phase difference, pulse + direction, addition/subtraction, 400kpps (for x4),  32-bit channel x 1 
F3XP02-0H Up/down counter, phase difference, pulse + direction, addition/subtraction, 400kpps (for x4), 32-bit channel x 2 
Positioning module
(with multi-channel
pulse output)
F3YP22-0P 2-axis control, 7,996kpps max. for servo/DD/Linear motor control, 1,999kpps. for stepping motor control
F3YP24-0P 4-axis control, 7,996kpps max. for servo/DD/Linear motor control, 1,999kpps. for stepping motor control
F3YP28-0P 8-axis control, 7,996kpps max. for servo/DD/Linear motor control, 1,999kpps. for stepping motor control
Positioning module
(with pulse output) 
F3NC32-0N 2-axis control, 5Mpps max. pulse output, PTP and linear/circular interpolation, direct/pattern operation, counter for ABS encoder input (2ch) 
F3NC34-0N 4-axis control, 5Mpps max. pulse output, PTP and linear/circular/helical interpolation, direct/pattern operation, counter for ABS encoder input (4ch) 
Positioning module
(with analog voltage
output) 
F3NC51-0N 1-axis control with speed reference voltage output type
F3NC52-0N 2-axis control with speed reference voltage output type 
Positioning module (with
MECHATROLINK-II
interface) 
F3NC96-0N 15-axis control with MECHATROLINK-II  interface 
Positioning module (with
MECHATROLINK-III
interface) 
F3NC97-0N 15-axis control with MECHATROLINK-III  interface

* WideField3 R4.05 or later must be used to use F3SP22-0S in up to 30K steps.
   When using WideField3 R4.04 or earlier, there is a limit of up to 10K steps.

 

Software

Category Name Type name Specification
Development tool FA-M3 Programming Tool WideField3 SF630-MCW* Windows 10, 11 compatible, multi-lingual version, Live Logic Analyzer function, CD-ROM
Simulation FA-M3 Simulation Software Virtual-M3 SF681-MDW* Windows 10, 11 compatible, multi-lingual version, Web download
Configuration tool ToolBox for Temperature Control
and Monitoring Modules
SF661-MCW Windows 10, 11 compatible, multi-lingual version, CD-ROM (for F3CU04 and F3CX04)
ToolBox for Positioning Modules
(for F3NC3x)
SF662-MCW Windows 10, 11 compatible, multi-lingual version, CD-ROM  (for F3NC3x)
ToolBox for Positioning Modules
(for F3YP2x)
SF663-MCW Windows 10, 11 compatible, multi-lingual version, CD-ROM  (for F3YP2x)

* There is also the package "SF631-MCW" of SF630-MCW and SF681-MDW as a set.

⇒ Software Download

Peripheral Devices

Name Type name Specification
CPU port / D-sub 9-pin conversion cable KM10-0C D-sub 9-pin, female, cable length approx. 0.5m (for F3SP22-0S)
SIO port adaptor cable KM10-0S SIO port / D-sub 9-pin, female, cable length 0.5m (for F3SP66-4S, F3SP67-6S)
Cable for programming tool KM11-2T DOS/V compatible, cable length approx. 3m
KM13-1S USB 1.1 compliant USB-serial converter, cable length approx. 3m
Monitor cables KM21-2A CPU port / D-sub 25-pin, male, cable length 3 m (for F3SP22-0S)
KM21-2B CPU port / D-sub 9-pin, female, cable length 3 m (for F3SP22-0S)
KM21-2N SIO port / D-sub 25-pin, male, cable length 3 m (for F3SP66-4S, F3SP67-6S)
KM21-2T SIO port / D-sub 9-pin, female, cable length 3 m (for F3SP66-4S, F3SP67-6S)
Cable for fiber-optic FA-bus (for use inside panel) KM60-S06 For use inside panel, cable length approx. 0.6m
KM60-001 For use inside panel, cable length approx. 1m
KM60-003 For use inside panel, cable length approx. 3m
Cable for fiber-optic FA-bus (for indoor use) KM61-xxx For indoor use, cable length
KM65-xxx For indoor use, cable length
Cable for fiber-optic FA-bus (for outdoor use) KM62-xxx For outdoor use, cable length
KM69-xxx Flame-retardant cable (equivalent of VW-1), For outdoor use, cable length
YHLS slave units
(TAH series)
TAHWD32-3PAM 16 DC inputs (positive common), 24V DC, MIL,
16 TR outputs (sink-type, with short-circuit protection), 24V DC 0.1A, MIL
TAHWD32-3NBM 16 DC inputs (negative common), 24V DC, MIL,
16 TR outputs (source-type, with short-circuit protection), 24V DC 0.1A, MIL
TAHXD16-3PEM 16 DC inputs (positive common), 24V DC, MIL
TAHXD16-3NEM 16 DC inputs (negative common), 24V DC, MIL
TAHYD16-3EAM 16 TR outputs (sink-type, with short-circuit protection), 24V DC 0.1A, MIL
TAHYD16-3EBM 16 TR outputs (source-type, with short-circuit protection), 24V DC 0.1A, MIL
YHLS communication cables KM80-xxx Flame-retardant cable (equivalent of VW-1), YHLS fixed cable, cable length
KM81-xxx Flame-retardant cable (equivalent of VW-1), YHLS flexible cable, cable length
Terminal block unit TA40-0N Converts 40 point I/O connector to European type terminal block.
Conector terminal block TA50-0N Connector terminal block (40 points), M3.5 screw
Cable for conector terminal block KM55-xxx Cable between module and terminal block, length from 0.5m (-005) to 3m (-030) in 0.5m increments
Blank module F3BL00-0N For empty I/O slots
Input simulator switch S9307UF Simulator switch for input terminals (for F3XD32-xF, F3XD64-xF, F3WD64-xx)

 

Common Specifications

Item Specifications
Environment Surrounding air temperature range Operating : 0 to 55°C *1
Storage : -20°C to 75°C
Surrounding humidity range Operating : 10 to 90% RH (non-condensing)
Storage : 10 to 90% RH (non-condensing)
Surrounding atmosphere Must be free of corrosive gases, flammable gases or heavy dust.
Grounding AC Power supply module : Protective earth (Comply with the regulation of each country.)
DC Power supply module : Functional earth
Noise immunity Tested using a noise simulator with a noise voltage of 1500 Vp-p, pulse width of 1 μs, rise time of 1 ns, and repetition frequency of 25 to 60 Hz.
For CE Marking-compliant modules, compliant to EN61326-1, EN61326-2-3*4 and EN61000-6-2
Vibration resistance Tested in compliance with JIS C60068-2-6 under the following conditions:
- Frequency ranges:
                                  10 to 57 Hz with an amplitude of 0.075 mm
                                  57 to 150 Hz with an acceleration of 9.8 m/s2 (1G)
- Direction and sweep cycles: 10 times each in the X, Y, and Z directions
Shock resistance Tested in compliance with JIS C60068-2-27 under the following conditions:
- Direction and sweep cycles: 3 times each in the X, Y, and Z directions with an acceleration of 147 m/s2 (98 m/s2 with DIN-rail mounting)
Structure & Appearance Structure Designed for mounting inside a panel enclosure
Altitude of installation Max. of 2000 m above sea level
Cooling method Natural-air cooled
Mounting Direct mounting with M4-size setscrews or DIN-rail mounting (except for F3BU16-0N module)
Finish color Light cobalt blue, equivalent to Munsell 6.2PB 4.6/8.8; Lampblack, equivalent to Munsell 0.8Y 2.5/0.4

*1 : Some FA-M3 modules may have a narrower surrounding temperature range than 0-55°C. A system incorporating such modules must be used within the narrower surrounding temperature range for such modules.

 

External Dimensions

Unit: mm

Base module Number of slots Number of I/O slots*2 Total width
F3BU04 4 3 147
F3BU05 5 4 205
F3BU06 6 5 205
F3BU09 9 8 322
F3BU13 13 12 439
F3BU16 16 15 527

*2 : The number of available I/O slots is indicated assuming that one CPU module is installed.

External Dimensions

FA-M3 Manufacturer's warranty

This is to explain the manufacturer’s warranty by Yokogawa Electric Corporation (hereinafter referred to as "Yokogawa Electric") for its FA-M3 products (“Warranty”). Please note that the warranty for the FA-M3 products you purchased may differ from this Warranty. For more details of the warranty specifically applying to you and conditions of use, etc., please consult with Yokogawa Electric Sales Representative or authorized sales representative.

1. Application

1.1 Warranty

This Warranty applies to the FA-M3 hardware products (standard hardware products and custom hardware products), including modules, cables connectors and terminals, manufactured and sold by Yokogawa Electric.
The term "standard hardware product" refers to a product that is identified as manufactured by Yokogawa Electric and specified in its brochures or its General Specifications ("GS") provided by Yokogawa Electric.
The term "custom hardware product" refers to a hardware product that is manufactured by Yokogawa Electric based on the functional specifications created through agreement between the customer and Yokogawa Electric and that is identified by the Yokogawa Electric trademark labeled on it.

1.2 No Warranty

This Warranty shall in no event apply to the accessories for the above-mentioned FA-M3 hardware products.
Further, this Warranty shall in no event apply to the Yokogawa products which were modified, fixed, repaired or adjusted, or with a part replaced by any entity other than Yokogawa Electric representatives or service providers authorized by Yokogawa Electric.
Please also note that this Warranty is subject to the conditions as set forth in Section 4 below.

2. Standard Hardware Product Warranty

2.1 Warranty Period

Yokogawa Electric warrants the standard hardware products for a period of twelve (12) months from the date of delivery to the location specified by the customer, or eighteen (18) months from the date of manufacture, whichever comes first.
The date of manufacture of FA-M3 is identified by the date of manufacture (DATE) described on the label.
Provided, the standard hardware products manufactured in or before November 2001 are identified by the serial number (NO.) as shown below.

Example: For Serial No. H0J230045

First letter (H) Manufacturing plant code
Next letter (0) Manufacturing year code (The last digit of the year)
Next letter (J) Manufacturing month code (A=Jan, B=Feb, ..., H=Aug, J=Sep, ..., M=Dec, with "I" unused)
Next two letters (23) Manufacturing date code (1 to 31)
Remaining letters Manufacturing data

Serial No. H0J230045 indicates that the product was manufactured in Plant H on September 23, 2000.

2.2 Warranty Coverage

If a failure attributable to Yokogawa Electric occurs during the warranty period, Yokogawa Electric will replace the product at no charge in accordance with Section 2.3 below.
The customer, however, shall be charged for the service even within the warranty period for the following cases:
(1) When the manufacturing information such as serial No. cannot be identified due to a missing or defaced label.
(2) Failures caused by improper handling or misuse of the product by the customer or anyone other than Yokogawa Electric.
(3) When the product is handled, stored or used under an environment (for example, exposed to condensation) that does not conform to the design specifications and installation conditions specified in the user's manual.
(4) Failures caused by fire, flood, storm, earthquake, lightning or other natural disaster, smoke, gas or other pollution, abnormal voltage, or other force majeure events.
(5) Failures caused by use of power supply that is not specified by Yokogawa Electric, other equipment connected to the product, or other external causes.
(6) Failures due to normal wear and tear of parts or consumables (cables, connectors, EEPROM: memory device with overwrite life, and contractor relay, etc).
(7) Other failures not attributable to Yokogawa Electric.

2.3 What to Do During Warranty Period

If a failure attributable to Yokogawa Electric occurs during the warranty period and a warranty claim is received in an expeditious manner, Yokogawa Electric will perform the following:
(1) Please contact the Yokogawa Electric Sales Representative or reseller where you purchased the product, providing the failed product along with the conditions related to the failure and probable cause of the failure. Yokogawa Electric will replace the product at no charge. In this event, be sure to return the failed product to Yokogawa Electric. In this case, the warranty period of the replacement product that has been replaced with the failed product shall be the same as that of the failed product before it was returned.
(2) In principle, no failure cause investigation or investigation report will be provided. If a special request for such investigation and report is made by the customer, it will be separately determined including the feasibility. The cost of the cause investigation and other required actions, if conducted according to the customer's request, shall be charged to the customer.
(3) If the claimed product proves non-defective, or the failure proves attributable to the customer, the cost of repair or other required operations shall be charged to the customer.

2.4 Equipment Manufactured by Third-Party Manufacturer

For equipment manufactured by a manufacturer other than Yokogawa Electric, the conditions of the warranty period and coverage specified by that manufacturer or provider of the equipment shall be applied, regardless of the descriptions in this document.

3. Custom Hardware Product Warranty

The same warranty conditions as those for the standard hardware products shall be applied to the custom hardware products, provided, this warranty may be subject to the condition that the customer purchases spare articles for warranty services.

4. Cautions on Using Products

(1) For the purpose of protection and safety of Yokogawa Electric products and the systems controlled with Yokogawa Electric products, make sure to obtain the user's manual provided separately by Yokogawa Electric (for purchase) and conform to the safety-related instructions and other cautions in handling Yokogawa Electric products. Failure to conform to those instructions and cautions may impair the functions such as protective functions of the Yokogawa Electric products. In this case, Yokogawa Electric does not warrant the quality, performance, functions or safety of the corresponding Yokogawa products.
(2) The customer is responsible for proper planning, preparation and implementation of independent processes, such as the development of a system using equipment provided by any party other than Yokogawa Electric, when installing a protection/safety circuit such as a lightening protection system for equipment for Yokogawa Electric products and control systems, or when establishing and applying foolproof design, failsafe design and other protection/safety circuits for the processes and production lines that use Yokogawa Electric products and control systems.
(3) Ensure that a part or consumable of Yokogawa Electric products is replaced with a part designated by Yokogawa Electric.
(4) None of the Yokogawa Electric products are intended for use in the operation of nuclear-related equipment, railway facilities, aircraft navigation or communication equipment, marine equipment, air traffic control facilities, medical equipment or for any other uses where the failure of the products could lead to death, personal injury, or severe health damage. To apply any of the products to equipment or system directly affecting human safety, the customer shall take responsibility to establish a system to assure safety without using equipment or systems provided by Yokogawa Electric.

Durable period and limited life time parts

Durable period of module:10 years

But the parts of the following modules have the limited life time.

 

Limited life time parts

  1. Aluminum Electrolytic Capacitors

    Recommend replacement cycle: 8 years from the date of factory dispatch
     
    Power supply module F3PU01-0N*, F3PU10-0N*, F3PU10-0S, F3PU16-0N, F3PU20-0N*, F3PU20-0S, F3PU26-0N, F3PU30-0N*, F3PU30-0S, F3PU36-0N*, F3PU36-0S, F3SP05-0P*,
     F3SP08-0P*, F3SP08-SP
    Analog input module F3AD04-0N*, F3AD04-0V*, F3AD04-0R*, F3AD08-1N*, F3AD08-1V*, F3AD08-1R*, F3AD08-4V*
    Analog output module F3DA02-0N*, F3DA04-1N*, F3DA08-5N*
    Temperature control and monitoring module F3CT04-0N*, F3CT04-1N*, F3CR04-0N*, F3CR04-1N*
    PID control module F3CV04-1N*
    Positioning module F3NC51-0N, F3NC52-0N, F3NC61-0N
    Handy programming console PR30-0N*

    * : Order entry stop products
     

  2. Relays

    Electrical life time:100,000 times or more
    Mechanical life time:20,000,000 times or more
     
    Power supply module F3PU01-0N*, F3PU10-0N*, F3PU10-0S, F3PU16-0N, F3PU20-0N*, F3PU20-0S, F3PU26-0N, F3PU30-0N*, F3PU30-0S, F3PU36-0N*, F3PU36-0S, F3SP05-0P*, F3SP08-0P*, F3SP08-SP
    Relay output module F3YC08-0C, F3YC08-0N, F3YC16-0N
    * : Order entry stop products
     
  3. Photocouplers

    Recommended replacement cycle: 5 years (when used at temperatures above 45°C)
     
    FA-Link module F3LP01-0N*
    FA-Link H module F3LP02-0N
    High-Speed Counter module F3XP01-0H,F3XP02-0H
    Analog input module F3AD04-0N*, F3AD04-0V*, F3AD04-0R*, F3AD08-1N*, F3AD08-1V*, F3AD08-1R*, F3AD08-4V*
    Temperature Monitoring module F3CX04-0N
    Temperature Control and PID Module F3CU04-0N*, F3CU04-1N*
    * : Order entry stop products
     
  4. Hard disk

    Recommended replacement cycle:5 years from the date of factory dispatch or 20,000 operation hours, whichever comes earlier.
     
    Hard Disk Module F3HD30-0N*, F3HD31-2N*, F3HD31-3N*

    * : Order entry stop product
     

Replacement of limited life time parts 

Please replace module as well as battery.

< Definition of limited life time parts >
The limited life time parts are the parts that the abrasion problem comes earlier than the durable period.
The parts having the life time more than 10 years is not included.

Recommend replacement cycle is defined to the period of module preventive maintenance
which has life limitation parts, not to accidental failure guarantee.

 

Standard compliant

Please refer to the General Specifications "Standard compliant products"

Document Title Document Number
Standard compliant products GS 34M06C11-21E

About some old FA-M3/e-RT3 products

Since its debut 20 years ago, the FA-M3/e-RT3 has released new, innovative, advanced-function products every year. Today, some electronic parts used in older products have become unavailable, and discontinuation of production or more electronic parts is expected due to mandatory compliance with various standards and directives.

In our efforts to ensure continued sales and reliable service to our customers, we have in the past stocked many discontinued parts, but a depleting inventory is posing difficulties for future production system maintenance, quality assurance and repair service. We have thus made the difficult decision to end the sale of some old FA-M3/e-RT3 products.

We advise customers to plan for alternative designs and migration. Thank you for your understanding and support.

 

List of End-of-Sales Products

Please refer to the Technical Information "FA-M3 / e-RT3 List of End-of-Sale Products"

Document Title Document Number
FA-M3 / e-RT3 List of End-of-Sale Products TI 34M06Z40-01E

Zasoby

Przegląd:
  • The NEP Solar team developed the control strategy and the Yokogawa engineers programmed the controller accordingly. 
  • The FAST/TOOLS software could be installed on the notebook PCs used by the development team, eliminating the need for costly dedicated servers.
Przegląd:

Aboitiz Power Corporation is a holding company that was set up by the Aboitiz Group to oversee its investments in power generation, distribution, retail, and services. The company owns and operates several hydroelectric and geothermal power plants as well as a number of non-renewable power facilities throughout the Philippines. It also owns distribution utilities that are centered in high-growth areas in Luzon, Visayas, and Mindanao.

Przegląd:

TSE proposed to customer a floating solar PV system that floats in water storage pond, cooling ponds, and wastewater ponds in the plant.
Yokogawa's CI Server and FA-M3 PLC contribute to the production of clean power for the plant.

Przegląd:
  • Yokogawa's FA-M3 PLC improves efficiency and accuracy at the lubricant blending processes in Thailand.
  • FA-M3 is integrated with SFC Excellence's enterprise resource planning and recipe management system.
Przegląd:
  • Yokogawa supplied an integrated boiler and turbine control, monitoring and protection system for each of the four generating units in a coal-fired power plant in Australia.
  • Yokogawa also delivered two high fidelity operator training simulators for this plant.
Przemysł:
Przegląd:
  • Hibiki LNG Terminal is supplying natural gas to a broad area of northern Kyushu.
  • CENTUM VP and FA-M3V provide a centralized monitoring environment and contribute to safe and stable operation.
Przemysł:
Sprawozdania techniczne Yokogawy
Przegląd:

With the recent rapid advancement of technology, user equipment has become more and more complicated, diversified and faster. This has been imposing an increase in engineering costs and increasingly many users require devices facilitating customization and the reuse of past resources (legacies).

Przemysł:

Downloads

Informacje techniczne

Wideo

Przegląd:

YOKOGAWA aspires to establish Smart GMP manufacturing facilities that provide consistent quality and supply while eliminating industrial waste, enhancing productivity and always using high-quality component parts and materials.

Szukasz dodatkowych informacji na temat naszych pracowników, technologii i rozwiązań?

Kontakt

Targi