Introduction
The pulp and paper industry has very aggressive and challenging applications for magmeters. There are corrosive Zone chemicals, high temperatures and pressures, and abrasive slurries. Yokogawa can provide the most reliable and accurate meters for each application.
Expected benefits
- Stable and accurate measurement under aggressive slurry maximize the productivity.
- Minimal downtime and maintenance work.
- Longer life-time by robust design
- Reduced cost of ownership.
Application
In the digester application, pulp is produced by placing wood chips into a digester where it is cooked under high pressures and temperatures in a caustic solution termed white liquor (a mixture of sodium hydroxide (NaOH) and sodium sulfide (Na2S)). The mixture of wood chip and liquor is steam heated, and the wood chips are dissolved. The spent mixture of white liquor and lignin is known as "black liquor". After the cooking, the pulp is discharged from the bottom of the digester using a blow-unit through the blow valve and into the blow tank.
Challenges
In the flow measurement in the digester applications, following two applications are the most challenging.
- Black liquor measurement in circulation/extraction process
- Pulp slurry measurement in Blow line.
And conventional magmeters have following problems.
- Heavy pulp slurry generate the slurry noise and produce an unstable output with resulting the loss of accuracy and control.
- Measuring heavy slurry the pulp stock due to problems related to the electrode seals and liner abrasion which results in a short life expectancy.
- The adhesive black liquor require frequent maintenance for the electrode cleaning.
Solutions
ADMAG AXF series delivers stability and durability in each applications that contributes maximize the plant productivity and reduce the maintenance cost.
Application | Typical process condition | Challenges | Yokogawa's solution |
---|---|---|---|
Blow Line | Fluid: Pulp Consistency: 10w/o< Process Temperature: 80-120°C Process Pressure: 2MPa max. |
• Liner abrasion • Slurry noise |
• Dual frequency excitation • Ceramic Liner (<=200mm) • PFA lined AXF with metal hat(>200mm) |
Circulation /Extraction Line | Fluid: High Consistency Caustic Soda Process Temperature: 150-180°C Process Pressure: 2MPa max. |
• High temperature • High pressure • High consistency alkali • Adhesive fluid |
• PFA lined AXF with insertion type electrode & metal hat • Flange type recommended |
Key Technologies:
ADMAG AXF (Remote type) |
- Dual frequency excitation provides good zero stability, the accuracy of 0.35% of reading and immunity to slurry noise. The advanced design of the flowtube ensures an accurate and reliable measurement of the difficult applications such
as circulation/extraction line or blow line, helping the user to optimize the process control and the performance of the plant operation. - Reliable flow tube design with the PFA liner retained with metal plate and the spring loaded electrodes realize the mechanical robustness, and extends the life time of the flow meter. In addition, the use of a metal hat protect the leading edge of the flow tube by covering the front leading edge of the lining.
- The ceramic lined AXF enabled accurate and stable flow measurement of the line measuring very aggressive slurry. The purity of alumina reaches 99.9% and provides better corrosion resistance and mechanical strength. This design allows no room for leakage, and provides extremely slurry resistant, enabling stable and accurate measurement. In addition, the optional mirror finished surface reduce the adhesion level by having smooth surface.
- The electrode coating diagnostics functions delivers the four levels of coating. This function can be optimization by each customer for his individual process, and the values for the four levels can be individually set in the field. This allows the user to predict when preventive maintenance is needed, and remove the meter for cleaning before an interruption in the measurement occurs.
Przemysł
-
Przemysł papierniczy
The paper and pulp industry is highly competitive and must meet ever-changing market needs. Yokogawa helps realize energy-efficient plants which are globally sustainable.
Powiązane produkty i rozwiązania
-
ADMAG AXF
The AXF magnetic flow meter is a sophisticated product with outstanding reliability and ease of operation, developed on the basis of decades of field experience. Based on FOUNDATION™ Fieldbus specifications, AXF Fieldbus Magnetic Flow meter models offer more flexible instrumentation.
-
Magnetic Flowmeters
Yokogawa's experience with magnetic flowmeters spans decades. Our magnetic flow meters provide flexible configurations for industrial use in most areas.