The small metal Rotameter RAKD differentiates itself from other comparable variable area meters by means of light and guided float design offering the smallest measurable flow ranges in the market. RAKD meters can be fitted with a fine control valve and are designed with horizontal process connections.
An integrated flow controller based on the differential pressure principle, which allows a constant flow rate to be maintained regardless of any variations in process pressure, is just one of the many different options available. The RAKD with either standard or fail safe limit switches is suitable for safety applications up to SIL level 2. The configuration with valve and controller reaches SIL level 1.
The RAKD Rotameter combines several benefits of the float principle: a robust design, reliable measurements, independence of the electrical power supply when operated as mechanical pointer instruments and an electrical output signal. They are moreover easy to install and require no maintenance. Both the RAMC and the RAKD are packaged in an attractive, all-stainless steel housing and boast a long service life under the harshest industrial conditions.
Details
Features
- Easy-to-read-display
- All stainless steel design
- Suitable for applications according to IEC 61508 and ISO 13849-1
- Adjustment valve and flow controller available
- Fast connection technique using Quickon connector
- Intrinsically safe outputs
- Special material like Monel and Hastelloy on request
Specifications
Refer to the General Specification sheet located under the 'Downloads' tab for detailed specifications.
For Pipe Sizes | DN 15 to DN 25 (1/4 inch to 1 inch) |
---|---|
Process Connections | Flange, threaded, cutting ring, nozzle and Swagelok |
Measuring Range | Water 20 °C: 0.1 l/h to 250 l/h Air 20 °C 1 bar abs.: 4 l/h to 8000 l/h |
Wetted Parts Material | 1.4571 (AISI 316Ti) Hastelloy, Monel and Titanium on request |
Process Temperature | -25 °C to + 250 °C |
Process Pressure | 160 bar, higher pressures on request |
Ambient Temperature | -25 °C to 80 °C |
Measuring accuracy acc. VDI/VDE 3513 sheet 2 (qG=50 %) | 4 % |
Hazardous Area Approvals | ATEX, IECEx, FM, NEPSI, EAC and KOSHA |
Signal Outputs | Analog 4 to 20 mA, pulse output |
Power Supply | 24 V DC 2-wire |
Degree of Protection | IP66 / IP67 |
Suitable for Applications acc. IEC 61508 and Machinery Directive ISO 13849-1 |
Yes |
Additional Features | Limit switches for low/high alarms Fine control valves Pressure controller Easy installation with Quickon connector |
FlowConfigurator
Welcome to the FlowConfigurator:
Selecting the flowmeter that best meets your specific needs and requirements.
The FlowConfigurator allows you to generate your data sheet and save your sizing projects for easy reuse.
FlowConfigurator
Resources
With the increased interest in green energy and renewable fuel sources, Biodiesel has emerged as a viable alternative to standard petroleum based diesel and home heating oil. It has zero CO2 emissions and can be created from waste vegetable oil or rendered animal fat. The number of Biodiesel processing plants has grown to over 2500 in the US alone.
One of the most widely used methods of monitoring / controlling liquid level in a tank is the use of Bubble Tubes with Pressure or Differential Pressure Transmitters. A small but uninterrupted flow of air or inert gas is forced down through a dip tube which extends to near the bottom of the tank. The back pressure of the introduced gas is a function of the liquid level or head in the tank. The pressure transmitter takes the back pressure and converts it to an analog signal that is sent to the control room. The plant operator will then be able to monitor the exact level in the tank.
One of the major prohibitive factors for expanding solar power in the market place is the high cost. The primary cost drivers in solar cell marketing are materials and manufacturing processes. Most solar cells in use today use silicon as the semiconductor that enables the photoelectric effect within the solar cell. Silicon is abundant but also expensive and in high demand as the solar and electronics industries compete for global supplies. There is now a cost effective process in use to extract the pure silicon needed for solar cells using less energy and reduced cost. This process is called the Fluidized Bed Reactor.
For nearly 100 years, ozone has been used all over the world for water sanitation. It is nature's strongest oxidizer and has a byproduct of pure oxygen. Chlorine, on the other hand, is a very effective, time-proven chemical, but is ineffective against hard-to-kill microorganisms such as cryptosporidium; it also has some unpleasant byproducts. Ozone is recognized among the strongest, fastest, commercially available disinfectants and oxidants for water treatment, Ozone is used in both the disinfection of drinking water and bacterial killer in waste water treatment. Ozone is used in a large percentage of Municipal water treatment facilities as well as Pharmaceutical companies where pure water is essential.
Downloads
Brochures
- Rotameter (5.1 MB)
Instruction Manuals
- Metal Rotameter RAKD (3.0 MB)
General Specifications
- Metal Rotameter RAKD (974 KB)
Looking for more information on our people, technology and solutions?