pH and ORP Sensors

pH and ORP Sensor pH ORP Analyzer

pH & ORP Sensors

Ensure confidence in your fluid process operations

pH electrodes and sensors are the sensing portions of a pH measurement.

Yokogawa Industrial pH Measurement

Yokogawa offers a variety of analog and digital pH electrodes/sensors and ORP sensors to meet your application needs for inline pH or ORP monitoring of water or other fluids. Various installation options include retractable, flow thru, immersion, and direct insertion. Proper pH electrode/sensor selection is critical for optimal measurement results. View our pH quick reference poster.

Detalles

pH and ORP Analyzers

  FLXA402 FLXA202/FLXA21
Area Classification General Purpose
Class I Div II
General Purpose
Class I Div I
Class I Div II
Power Supply 110VAC, 24VDC
(4-wire)
24VDC loop-powered
(2-wire)
Communication 4-20mA, HART, Modbus
(Ethernet, RS-485), Bluetooth
4-20mA, HART, FF and PA*
Contacts and Relays 4 SPDT relays None

pH/ORP Calibration Solutions

Either of these pH buffer solutions can be used for calibration of an ORP measuring system and are very practical if pH loops are also being maintained

  • Pre-made Stabilized ORP Solutions

Premade solutions designed to provide a specific stable mV value, typically one that falls within the process ORP range

  • Quinhydrone Solution 

Solutions made using the standard pH 4 and pH 7 buffers with quinhydrone crystals mixed in until saturation is reached

Recursos

Descripción General:
  • Más de 1,000 equipos de campo diseñados para las especificaciones de PROFIBUS fueron instalados en la planta de regeneración de agua state-of-art.
  • La alta confiabilidad y precisión de nuestros dispositivos de campo contribuye a la minimización de los costos de mantenimiento durante todo el ciclo de vida de la planta
Descripción General:

For control of batch neutralization, a pH measurement coupled with a timer-controlled chemical feed scheme provides very satisfactory results.

This system can be adapted for either acid waste or alkaline waste neutralization.

Descripción General:

Wet scrubbers are used in utilities, paper mills, and chemical plants to remove sulfur dioxide (SO2) and other pollutants from gas streams. Undesirable pollutants are removed by contacting the gases with an aqueous solution or slurry containing a sorbent. The most common sorbents are lime, Ca(OH)2, and limestone, CaCO3

Industrias:
Descripción General:

Dairy wastewater is a mixture of organic compounds, suspended solids, fats, and bacteria that can produce a film or coating on equipment in the process. 

Descripción General:

The proliferation of microorganisms and the resultant formation of slime is a problem which commonly occurs in aqueous systems. Problematic slime producing microbes may include bacteria, fungi and/or algae. Slime deposits typically occur in many industrial aqueous systems including cooling water systems, pulp and paper mill systems, petroleum operations, clay and pigment slurries, recreational water systems, air washer systems, decorative fountains, food, beverage, and industrial process pasteurizers, sweetwater systems, gas scrubber systems, latex systems, industrial lubricants, cutting fluids, etc.

Industry:Refining, Food and beverage, Power, Oil and Gas, Pulp and Paper, Chemical

Industrias:
Descripción General:

Process liquid analyzers such as pH meters, conductivity meters, ORP meters, and density meters play an important role at electrolysis plants in the control of concentrations of various process solutions. This requires both precision and stability under harsh conditions that include highly corrosive substances, high temperatures, and many impurities.

Descripción General:

La sosa cáustica y ácido clorhídrico, producida en las plantas electrolizadoras, son materiales fundamentales utilizados en varias industrias; químicas, farmacéuticas, petroquímicas, pulpa y papeles, etc. El beneficio es el resultado de la producción efectiva con costos de explotación/mantenimiento mínimos. El control adecuado del proceso genera estabilizado productos de calidad estables con una gran ganancia operativa.

Descripción General:

Cyanide-bearing wastewater from mining and electroplating facilities and certain types of chemical plants is toxic and must be treated by oxidation with chlorine or chloride to bring the cyanide concentration within regulatory limits.

Industry:Electrical and Electronics

Descripción General:

In flue gas desulfurization systems that use magnesium hydroxide (Mg(OH)2) slurry, the consumption of the desulfurization agent (Mg(OH)2) is controlled by using online pH analyzers. A great concern in the pH measurement is heavy staining of the pH electrodes by the Mg(OH)2 slurry. To ensure accurate measurement, frequent cleaning of the electrodes with an acid is required, adding to both maintenance workload and cost.

Industry:Chemical, Power

Descripción General:

The treatment of wastewater from pulp and paper plants is a serious environmental concern. Yokogawa's submersion holder with an ultrasonic+air-jet cleaner (customized product) can reduce the manual cleaning frequency to just once every one or two months.

Industrias:
Descripción General:

Continuous technology improvement is ongoing in the pulp & paper industry to obtain the best possible performance. Problems at the wet end (stock preparation) can rarely be corrected downstream. That is why monitoring and controlling pH in pulp stock is critical to the paper making process. Essentially, at every stage in the manufacture of paper, correct pH values play a vital role.

Descripción General:

La mejora continua de la tecnología en curso en la industria de pulpa y papel sirve para obtener el mejor rendimiento posible. El desempeño mejorado de la planta se traduce en la mejora de la calidad y menor costo, al mismo tiempo una operación de la planta amigable con el medio ambiente.

Industrias:
Descripción General:

Wastewater from electroplating facilities and certain types of chemical plants contains toxic forms of hexavalent chromium such as chromate and dichromate. The hexavalent chromium in this wastewater must be reduced before the water can be discharged. This requires a two-step process: hexavalent chromium (CR6) is reduced to trivalent chromium (CR3); and CR3 is precipitated as chromium hydroxide.

Industry:Electrical and Electronics

Descripción General:

Sour Water is the wastewater that is produced from atmospheric and vacuum crude columns at refineries. Hydrogen sulfide and ammonia are typical components in sour water that need to be removed before the water can be reused elsewhere in the plant.

Industrias:
Descripción General:

Power plant boiler houses designed to burn coal or high sulfur oil are required by Federal and State pollution regulations to "scrub" (remove) sulfur dioxide from flue gasses to meet emission limits. SO2 in flue gasses is known to be harmful to the environment, as it is one contributor to the formation of acid rain. pH control is critical for the proper functioning of the scrubber system.

Industrias:
Aplicacione
Descripción General:

Wastes have been considered to be a serious worldwide environmental problem in recent years. Because of increasing pollution, these wastes should be treated. However, industrial wastes can contain a number of valuable organic components. Recovery of these components is important economically. Using conventional distillation techniques, the separation of acetic acid and water is both impractical and uneconomical, because it often requires large number of trays and a high reflux ratio. In practice special techniques are used depending on the concentration of acetic acid. 

Industrias:
Descripción General:

Many Ethanol plants running today are using a combination style pH electrode with a non-flowing reference to measure pH in the Mash Slurry transfer line from the Mash slurry mix tank to cook. The Mash is being pumped out of the Mash Slurry tank is at approximately 180 °F and 40 to 60 psig.

Descripción General:

Yokogawa’s Process Liquid Analyzers series help pigment producers achieve a more reliable and accurate analysis of pH during industrial bioprocesses, improving product quality with less total operation costs.

Descripción General:

Optimizing four key factors will decrease pH sensor costs and optimize process control and overall plant efficiency.

Documentación Técnica
Descripción General:

ORP (Oxidation-Reduction Potential) is the measurement, in millivolts, of a solution's capacity for electron transfer (oxidation or reduction). ORP measurement may also be called REDOX for REDuction OXidation. The name reflects that fact that within a chemical reaction reduction and oxidation are complementary; one cannot occur without the other.

Medios de Comunicación
Industrias:
Air bubbles are normal in pH sensors and in some reference sensors. They are necessary because the pH sensor is a sealed device with no vent. Without the air bubbles the expansion and contraction of the liquid with temperature changes could cause the...
The reference potential difference between 1 molar and 3.3 molar is approximately 30 mV. The sensitivity of a pH sensor at reference temperature is 59mV/pH. So if you combine a measuring cell filled with 3.3mol KCl with a reference cell with 1mol KCl...
That is possible but not guaranteed. The 225 mm sensor body is longer, so it has more electrolyte. Often the reference electrode fails because the electrolyte is depleted as it diffuses through the reference junction into the process. With ...
Most pH sensors with a glass membrane cannot be mounted upside down. To absorb the thermal expansion of the internal buffer solution there is always a sizeable air bubble inside the sensor. When the sensor is mounted upside down the reference element...
Yokogawa offers the PH18 sensor. This sensor is nonglass and suitable for regular CIP and SIP cycles. ...
Most of our pH sensors have a noble metal solution ground and our transmitters measures two values: 1.  the voltage between this solution ground, or liquid earth sensor and the pH sensor, and 2. the voltage between this solut...
This is a well-known pH problem that we call Diffusion Potential. If the sensor junction is partially plugged the electrical contact between electrolyte and process is not good. This results in a high diffusion potential and an error i...
NO!  Sensors that are not used need to be stored in a solution that guarantees that the sensor is ready for use. When the sensor is stored in pure water the salt will be washed out of the junction of the reference cell. This causes the sensor t...
Yes and No.  Yes - after cleaning you need to verify that the analyzer is reading correctly. The easiest way is to see how it reads when placed in 2 pH buffer soltuions. This is what you do when calibrating.  No - If the readings are with...
First - when you receive a new Bellomatic sensor it is shipped with a rubber stopper inserted into the pressure port on the bottom of the sensor. You must remove this stopper before putting the sensor in service. DO NOT DISCARD THIS STOPPER! Put it i...
Yes, the SENCOM Module in these sensors allows a Modbus Master to connect using Modbus RTU protocol and access the following data: pH Temperature compensated pH ORP pH compensated ORP rH Temperature Junction resistance value Sensor details ...
The short answer to this question is NO. But, there is a long answer that will give you another option. Yokogawa has created a Submersible Sensor Kit (part number M1289XT) for the FU20 pH sensors - M1289XU for the FU24 sensor). It is also known as ...
PH Sensor Cleaning
(KB-000-0380)
Cleaning pH Sensors Basic Steps  Rinse electrode in clean water Clean by immersing the electrodes in a cleaning solution (see below).  Rinse Again Check with buffers Cleaning Solutions: If you know a specific way to clean the sens...
Sensor lifetime is difficult to predict as it is dependent on a number of different factors such as pH value, temperature, pressure, the composition of the process liquid, maintenance activity is taken, storage conditions, and sensor handling. ...
Descripción General:

Sensor lifetime is difficult to predict as it is dependent on a number of different factors such as pH value, temperature, pressure, the composition of the process liquid, maintenance activity is taken, storage conditions, and sensor handling.

Yes you can, but we do not recommend this method. A pH sensor has a reference electrode that has a low impedance to the process. If the process suffers from common mode voltages or ground loops it will be difficult to measure the ...
The FF20 flow through holder for PH can be ordered using the "pH Selection Guide Matrix" so that an entire system can be ordered with one line item. This does not work if you want a FF20 with an FU20 sensor. The Matrix does not contain the ...
It is very important that the cables maintain a very high impedance. If any moisture penetrates the cable the impedance will drop and the cable will short out the voltage generated by the pH sensors. This will cause errors or a total loss of mea...
A tiny crack in the membrane of a glass electrode is not always visible to the naked eye. Frequent shocks may create cracks in the glass that cause measurment errors. These cracks will cause the analyzer to read 0 mV and the ...

Documentos y Descargas

MSDS/SDS

Videos

Información del Producto
Descripción General:

Glass blown pH electrodes at Yokogawa Europe.

Información del Producto
Descripción General:

How to install a Bellomatic probe in a holder and perform necessary maintenance. 

Descripción General:

While we strive to provide the most safe and accurate information possible, we are not responsible for any loss or damages resulting from attempting to replicate the acts conducted in this video. Furthermore, we shall not be held liable for use or misuse of information contained in this video.

Descripción General:

This video covers a PR10 installation and extraction. While we strive to provide the most safe and accurate information possible, we are not responsible for any loss or damages resulting from attempting to replicate the acts conducted in this video. Furthermore, we shall not be held liable for use or misuse of information contained in this video.

Descripción General:

Are Pure water, Ultrapure water, UPW, or Water for Injection (WFI) important in your process? Would a better understanding of current water treatment equipment technology be useful? Would learning to better identify sources for potential process problem be helpful?

Pure water, Ultrapure water, UPW, Water for Injection (WFI), high-purity water and deionized (DI) are all terms describing basically the same property. They refer to water which has been purified to the highest standards by removing all contaminants such as, organic and inorganic compounds; dissolved and particulate matter; volatile and non-volatile, reactive and inert; hydrophilic and hydrophobic; and dissolved gases. Pure water or conditioned water is used in a variety of processes across various industries; Power Generation, Pharma/Biotech, Semiconductor, and Drinking water are just a few examples. Please join us for a free 45 min webinar with 15 min Q&A section. As our presenter David H. Paul, Inc (DHP), gives an overview of high purity water treatment. What you will learn:

  • Understanding the purpose for each piece of equipment in a high purity treatment process flow
  • Basic overview of Reverse Osmosis Processes
  • Better understanding of when to "raise an alarm" when performance issues arise

Information about the presenter: Since 1988, David H. Paul, Inc (DHP) has been the world's leader in reverse osmosis and high purity water treatment training. DHP has trained over 18,000 water treatment professionals worldwide. For information on additional High Purity Water Treatment and Reverse Osmosis Water Treatment training please click on the link to DHP's website: www.dhptraining.com

Descripción General:

Proper pretreatment is critical for minimizing problems and reducing the need for chemical cleaning. This webinar will teach you the most common pretreatment technologies and why it is important to monitor and maintain them. Join us to learn:

  • Why pretreatment is important
  • How pretreatment protects your RO units from scaling, fouling and chemical attacks
  • What to monitor and why
Descripción General:

What about other instrumentation pain-points in the blow tank, washing, or bleaching process?

Descripción General:

In the digester process, high temperature and pressure, along with the slurry pulp, can cause extreme damage to traditional meters.

Descripción General:

This video aims to answer the following: How does a traditional pH reference work and what are it's common problems? How does a sodium pH reference work and what are it's benefits? This webinar was presented February 12th, 2013.

Descripción General:

Each of the previous webinars covered the basics and the monitoring requirements for a high purity water treatment system that included a Reverse Osmosis (RO) treatment step. In this final webinar, we cover the problems that poor RO unit performance can produce in downstream process steps and in the end use water. The webinar series started with topics concerning raw water contaminants and will end with following contaminants through the RO membrane and into downstream treatment steps including Electrodeionization (EDI), mixed-bed ion exchange, 185 nm and 254 nm UV, ozone and more. Join us and learn:

  • What and why certain measurement parameters should be monitored
  • When to "raise the alarm" when issues arise
Descripción General:

A common use for RO is for purifying water, removing salts and other impurities to improve the color, taste and other properties. It is regularly used for commercial and residential water filtration and is also one of the methods used for desalinization of seawater. RO systems are capable of rejecting bacteria, salts, sugars, proteins, particles, dyes, and other constituents which have a molecular weight of greater than 150-250 Daltons. RO systems are designed for automatic operation and require routine preventative and corrective maintenance. Common problems include membrane fouling and the use of improper flow rates. The result is reduced throughput capacity and shortened runs. What you will learn:

  • Overview of Reverse Osmosis Processes
  • Understanding of RO technology
  • Understanding the importance of RO operation and maintenance