The YFFC consists of Yokogawa’s EJX910 multivariable transmitter and Eagle Research’s Computer Processor Board to create Yokogawa’s Field Flow Computer (YFFC) and Remote Terminal Unit (YRTU) products. This technology turns complex gas flow calculations and remote control applications into a simple, flexible, and expandable platform through preprogrammed applications. Its low power consumption and rugged design assure reliable operation in the harshest environments. From gas wellhead monitoring and control to transport and distribution, Yokogawa’s Y-Flow® provides timely, accurate and reliable measurements that will increase your bottom line.
- API Chapter 21 compliance
- AGA 3 & 5 capability
- AGA 8 (Detailed & Gross Methods I & II) & NX-19
- Single and Bi-Directional (total vol. + avg. vol.) measurement
- Multiple run capability
- Solar panel with battery back-up or AC powered with battery back-up
- Wide array of wireless connectivity options (Cellular, wireless radio and satellite)
- Pole mount, wall mount or direct mount options
- Wide variety of enclosure size options
Detalles
Applications
Pre-configured Applications
AGA 3 Orifice Measurement | Tube/Run Switching |
AGA 5 Fuel Gas Calorific Measurement | Turbine Meter Profiling |
AGA 8 Gas Density Measurement (Detailed & Gross Methods I & II) | Compliance Alarming |
AGA-7 Measurement of Natural Gas by Turbine Meter | Tank Level Monitoring |
AGA-9 Measurement of Gas by Multi-Path Ultrasonic Meters (using AGA-7) | V-Cone Measurement |
AGA-11 Measurement of Natural Gas by Coriolis Meter (using AGA-7) | Plunger Lift |
NX-19 Gas Density Measurement | -- |
Emergency Shutdown | -- |
Valve Control | -- |
Wellpad Monitoring & Control
Yokogawa’s Y-Flow® YRTU is an effective and precise remote management controller that allows for maximized production while ensuring the production process is safe and reliable. By taking inputs from various instrumentations, the YRTU will process and monitor the data through pre-programmed or user-designed applications. The data is logged, stored and transmitted to a host/SCADA system via Ethernet (Modbus Serial, Modbus TCP) or wireless communication protocols.
Gas Measurement
Yokogawa’s Y-Flow® YFFC provides timely, accurate and reliable measurements anywhere, anytime. By combining the Y-Flow® with Yokogawa’s state-of-the- art coriolis, vortex and multivariable meters, accurate gas measurements are easier than ever. From orifice flow to steam measurement, Yokogawa’s Y-Flow® YFFC provides superior accuracy and reliability that ultimately reduces CAPEX and increase profit.
Gas Control
In an industry where safety and reliability is priority, Yokogawa’s Y-Flow® provides the control and peace of mind for operators and engineers alike. From emergency shutdowns to valve control and positioning, Yokogawa’s Y-Flow® is there to ensure the process is safe and sound.
Yokogawa EJX910A Multivariable Transmitter Accuracy Specifications
Specifications for the EJX910A are condensed for the purpose of this document. Please see GS01C25R01-01EN for more detailed information.
The EJX910A uses the established DPharp pressure sensor technology that allows for simultaneous measurement of differential pressure and static pressure (absolute or gauge) from one sensor. Out of all the Yokogawa pressure transmitters, the EJX910A has the best accuracy for combined DP and SP measurement, which makes it an excellent choice for flow calculations with a RTU.
Measurement Span/range |
DP inH20 | SP psia | |
---|---|---|---|
M | Span | 2 to 400 | 145 to 3300 |
Range | -400 to 400 | 0 to 3300 | |
H | Span | -10 to 2000 | 145 to 3300 |
Span | -2000 to 2000 | 0 to 3300 |
Reference Accuracy
(Includes terminal-based linearity, hysteresis, and repeatability)
- DP Up to ±0.04% of span standard
- SP ±0.1% of span (Absolute)
Long Term Stability (All normal operating conditions, including overpressure effects)
- DP ±0.1% of URL per 10 years Turndown
- DP 200:1
- SP 25:1
YFFC Technical Specification
Input Power Supply
- Input Power: 12-30 VDC
- One (1) power supply/rechargeable battery input with screw terminals
- Integrated solar panel charger supporting up to 20W solar panel
Power Monitoring and Battery Backup
- Supply voltage monitoring through A/D with low supply voltage alarm
- 3.6 VDC lithium ion battery backup for database, history, audit trail, time/date and RAM
- 20W on board battery charger, 90W maximum
- 32AH solar panel battery (optional)
Performance
- Processor: ARM Dual Core 32-bit
- Flash Memory: 32 megabit
- SRAM Memory: 32 megabit
- A/D: 16-bit with optional HART filtering
Display Options
- 4 line alphanumeric display with push button keypad
Operating Temperature
- -40C to 70C (-40F to 160F)
Communications Options
- Standard: Two (2) Serial RS-232/RS-485
- One (1) Ethernet Port, (1) USB Host Port, (1) USB Device Port
- Wireless Communication: Cellular (CDMA/GSM), Radio (spread spectrum licensed & unlicensed frequency), Satellite (LEO &GEO)
- Protocols: MODBUS TCP/IP, MODBUS Serial, ERC Hex ASCII (native)
Input and Output (I/O)
- Analog Inputs: Four (4) universal analog inputs, 0-5VDC or 4-20mA (Requires 250 ohm resistor)
- RTD Inputs: One (1) temperature probe
- Digital Input/Output: Two (2) form A/C pulse input, Two (2) form C relays, Two (2) DI, Two (2) DO
Software
- Field Manager
Optional Expansion Board Capability (9010449)
- Two (2) Serial RS-232/RS-485
- Four (4) universal analog inputs
- One (1) analog output
- One (1) RTD temperature probe
- Two (2) form A/C pulse input
- Three (3) DI, Three (3) DO
- Opto 22 G4 Voltage Signal Conditioner
Approvals
- UL Class I, Div II Group A,B,C,D (pending)
Warranty
- 4 years limited warranty
Accessories
Y-Flow® Extender Board
In addition to the standard I/O offered on the processor board, the FFC and RTU have the capability to expand I/O count by adding the Y-Flow® extender board. Furthermore, the extender board allows for Opto 22 G4 AC and DC input/output modules for applications that require switching loads such as DC relays, solenoids, motor starters, lamps and indicators.
Type | Count |
Serial RS232/RS485 | 2 |
Analog Inputs | 4 |
Analog Outputs | 1 |
RTD (Temp Probe) | 1 |
Pulse Inputs | 2 |
Digital Inputs | 3 |
Digital Outputs | 3 |
Opto 2 G4 Slots | 2 |
Recursos
Documentos y Descargas
Catálogos
- Y-Flow™ Product Family (1.4 MB)
Manuales
- Y-Flow™ and Accessories Manual (829 KB)
- Y-Flow™ Field Manager Manual (4.7 MB)
- Y-Flow Quick Start Guide (623 KB)
- Y-Flow Master Database 62102 (1.2 MB)
Especificaciones Generales
Software
- Field Manager (16.2 MB)
- 62102 Database (1.0 MB)
Dibujos
- Y-Flow™ Processor Board (915 KB)
- Y-Flow™ One Line Display (453 KB)
- Y-Flow™ 4 Line Display (450 KB)
- Y-Flow™ System Protection Module 35V (852 KB)
- Y-Flow™ Analog Output Expansion (E-AO) (187 KB)
- Y-Flow™ Expansion Serial Port (ESP) (413 KB)
- Y-Flow™ System Protection Module 8V (841 KB)
- Y-Flow™ System Protection Module 200V (858 KB)
- Y-Flow™ Extender Board (892 KB)
Noticias
-
Nota de Prensa oct 17, 2017 Yokogawa Corporation of America Releases Y-Flow® Flow Computer and Remote Terminal Unit
¿En busca de información adicional sobre Yokogawa Iberia, tecnología y soluciones?
Contáctenos