Kiyoshi Watanabe1
Diagnosing the process interface where the field instruments and process equipment are contacting each other enables prediction of the required maintenance for the instrumentation. With the EJX series differential pressure/pressure transmitters, Yokogawa has developed functions to detect blockage and monitor heat traces in impulse lines which are process interface parts. These functions are called advanced diagnoses, to distinguish them from the self-diagnosis of the instruments. This paper introduces the advanced diagnostic functions built in the FOUNDATION Fieldbus communication type and HART communication type EJX series transmitters.
- Field Instruments Business Center, Industrial Automation Business Headquarters
INTRODUCTION
Figure 1 Configuration of Diagnostic Functions in EJX Series |
Field instruments are expected to be equipped with diagnostic functions to predict abnormal process conditions, and are also expected to expand these functions. The ability to extract diagnostic information for prediction and prevention from various physical process quantities measured by devices and make it available allows the user to reduce non-essential and non-urgent maintenance and thus cut maintenance costs. There are high expectations for field instruments to improve diagnostic functions to facilitate the management of devices and plant operations and help cut maintenance costs1.
Yokogawa's EJX series differential pressure/pressure transmitter provides diagnostic functions to detect blockage in impulse lines and monitor heat traces for the process interface, a point where the devices and process equipment contact and interact. The diagnostic function consists of two functions, and both of them are related to impulse lines that is used to transmit the process fluid pressures to the transmitter. The one utilizes slight pressure fluctuations of the fluid to detect a blockage in the impulse lines. The other utilizes the temperature gradient corresponding to the thermal resistance inside the transmitter to estimate and monitor the status of heating equipment that is installed to prevent the fluid in the lines from freezing. These functions are called advanced diagnostic functions to differentiate them from the self-diagnostic functions of the device. Figure 1 shows the configuration of the diagnostic functions. The principles and details of the functions are described in Yokogawa technical report2 3. This report focuses on the expansion of the implementation of the functions to other models.
OVERVIEW OF ADVANCED DIAGNOSTIC FUNCTIONS
Figure 2 Installation of Impulse Lines for Differential Pressure Transmitter and Attenuation of Fluctuations |
The advanced diagnostic functions of the EJX series comprise multi-sensing (differential pressure, static pressure, and temperature measurements) characterizing the instruments and detection of abnormal conditions by monitoring the process environment applying proprietary algorithms.
Impulse Line Blockage Detection
A differential pressure/pressure transmitter measures pressures of process fluids that flow in the line, along with fluctuations caused by pumps or the like. Blockage is detected by utilizing the property that the fluctuations attenuate when the impulse line is blocked; specifically, by extracting the fluctuation components from the differential pressure/pressure values, comparing the degree of attenuation with the reference values obtained in normal operation, and making a judgment.
Figure 2 shows a typical installation of the impulse lines for a differential pressure transmitter and a schematic diagram showing the attenuation of fluctuations.
Heat Trace Monitoring
The soundness of the temperatures of the steam, heater etc. that keep the impulse lines warm is monitored by using the flange temperature estimated from the temperatures of the capsule and amplifier of the transmitter. Figure 3 shows a typical installation using a bundle tube for preventing freezing, and Figure 4 shows an estimation of the flange temperature from the capsule and amplifier temperatures.
Figure 3 Freeze Prevention Using Bundle Tube |
APPLICATION OF ADVANCED DIAGNOSTIC FUNCTIONS TO EJX SERIES
Figure 4 Estimation of Flange Temperature from Capsule and Amplifier Temperatures |
The EJX series is capable of independently detecting four modes of impulse line blockage: both side, high-pressure side, low-pressure side, and either one side by utilizing a multi-sensing function of a silicon resonant sensor capable of simultaneously measuring differential pressure, high-pressure- side static pressure, and low-pressure-side static pressure4. The EJX can be used not only for differential pressure but also for level and pressure measurements and is able to detect blockages in the impulse line on the pressure measurement side applying the same principle. The EJX is also able to monitor the flange temperature, even if the flange shape varies, because it estimates the flange temperature from the capsule and amplifier temperatures.
The EJX series consists of models designed for differential pressure, pressure, and level measurement applications. Since the diagnostic functions are not limited by the measurement applications, they are implemented in all the models supporting the FOUNDATION Fieldbus and HART communication protocols. Table 1 shows the blockage detection items for each EJX series model.
Table 1 EJX Models and Applicable Blockage Detection Items
Models | Names | Blockage Detection Items |
---|---|---|
EJX110/130 | Differential Pressure Transmitter | Both-side blockage High-pressure-side blockage Low-pressure-side blockage One-side blockage |
EJX118 | Diaphragm Sealed Differential Pressure Transmitter | |
EJX210 | Flange Mounted Differential Pressure Transmitter | |
EJX115 | Low Flow Transmitter | |
EJX910/930 | Multivariable Transmitter | |
EJX120 | Draft Range Differential Pressure Transmitter (for the both-side or one-side blockage only) | |
EJX430/440 | Pressure Transmitter | Impulse line blockage on the pressure measurement side |
EJX310 | Absolute Pressure Transmitter | |
EJX438 | Diaphragm Sealed Pressure Transmitter | |
EJX510/530 EJX610/630 | Pressure Transmitter (Screw Type) |
ADVANCED DIAGNOSTIC FUNCTION SPECIFICATIONS
Table 2 shows the specifications of the advanced diagnostic functions. The specifications of the diagnostic functions are the same between the two communication types except for the alarm output destination of the diagnostic results, the number of alarm setting items and others.
Table 2 Advanced Diagnostic Function Specifications
Diagnostic Functions | Communication Types | ||
---|---|---|---|
FOUNDATION Fieldbus | HART | ||
Impulse Line Blockage Diagnosis | Pressure Fluctuation Measurement Period | 100 msec | 135 (100) msec |
Diagnostic Period | 20 to 65535 sec | ||
Diagnostic Mode | Suspend diagnosis, acquire reference value, execute diagnosis | ||
Alarm Setting Items | 12 (11) items | 11 items | |
Diagnostic Alarm Output | Communication [AIFB] LCD display |
Communication LCD display 4-20 mA signal Contact output |
|
Heat Trace Monitoring Diagnosis | Temperature Measurement Period | 1 sec | |
Diagnostic Period | 1 sec | ||
Flange Temperature Output | Communication [STB, AIFB] LCD display |
Communication | |
Alarm Setting Items | None (2 items) | 2 items | |
Diagnostic Alarm Output | Communication [AIFB] (Communication [STB, AIFB]) (LCD display) |
Communication LCD display 4-20 mA signal Contact output |
AIFB: Analog Input Function Block
STB: Sensor Transducer Block
Note: Figures in parentheses for EJX910/930
ADVANCED DIAGNOSTIC PROCESSING
Figure 5 shows the flow of the advanced diagnostic processing and Table 3 shows the output related to the corresponding diagnosis.
Figure 5 Advanced Diagnostic Processing Flow
Table 3 Diagnosis-related Output
Output Destinations/Output Signal Parameters | Descriptions | ||
---|---|---|---|
FOUNDATION Fieldbus Communication Type | HART Communication Type | ||
(1) | VALUE_□ | Fluct Variables (Fluctuation Values) Diag Variables (Degree of Blockage) |
Fluctuation values and a degree of blockage of differential pressure, high-pressure-side static pressure, and low-pressure-side static pressure |
REFERENCE_□ | Diag Reference | Fluctuation reference values for differential pressure, high-pressure-side static pressure, and low-pressure-side static pressure | |
(2) | DIAG_ERR | Diag Error | Diagnostic results of impulse line blockage and heat trace monitoring |
(3) | DEVICE_STATUS | Device Status Status Group |
Description of the alarm detected as the diagnostic results. In case of HART communication type, Device Status is a representative notification and Status Group is a detailed notification. |
(4) | DIAG_H_ALM, DIAG_L_ALM | — | High-pressure-side and low-pressure-side discrete alerts resulting from blockage detection |
(5) | PV, SV, TV → AI. OUT | — | The blockage detection result is added to the status of the process value. The result is reflected in the OUT signal status of the AI function block. |
(6) | LCD Display | LCD Display | The detected alarm is displayed on the LCD. |
(7) | — | Analog Output | The detection result is reflected in the 4-20 mA analog signal output. |
(8) | — | Digital Output | The detection result is reflected in the contact output. |
Remark: The auxiliary parameter name indicating the fluctuation value or a degree of blockage is placed in □.
The impulse line blockage diagnosis calculates the pressure fluctuations of the differential pressure, high- pressure-side static pressure, and low-pressure-side static pressure every 100 milliseconds or 135 milliseconds, and performs statistical processing as well. Diagnosis and blockage detection are performed for every diagnostic period by combining the two kinds of variables: a fluctuation ratio of the reference value and diagnosing value and a degree of blockage that is obtained from the correlation of the fluctuations. The diagnostic period can be changed by the setting.
The heat trace monitoring diagnosis calculates the flange temperature from the capsule and amplifier temperatures every second and makes a judgment by comparing the value with the high and low threshold values.
While the diagnosis makes a judgment of all the items, the required diagnostic items are selected and the result is output according to the alarm output setting for the diagnostic result.
With the FOUNDATION Fieldbus communication type, the diagnostic alarm is reflected not only in the status output but also in the OUT signal of the AI function block. With the HART communication type, not only the Burnout and Fallback output by the 4-20 mA analog signal but also contact output is available. The following describes the main processing procedures.
Processing Procedures for Impulse Line Blockage Diagnosis
Figure 6 Alarm Masking (for HART Communication Type) |
The fundamental element of the blockage diagnosis is monitoring of the pressure fluctuations. A blockage is detected by comparing the current process fluctuation value with the reference fluctuation value in the normal state. Generally, when the differential pressure and static pressure are high, the fluctuations are also large so detection is stable. However, when levels or pressures are measured, when measured fluid is highly viscous fluid of which viscosity is larger than 10 centistokes (cSt), or when measured fluid is a gas, the fluctuations are not large enough to detect the blockage correctly. In this case, a diagnostic result error occurs, indicating that the diagnostic result is inadequate.
The blockage diagnosis is performed in the order of the acquisition of the reference values, confirmation of the blockage detection by the simulated blockage, and actual blockage detection. When obtaining reference values, it is confirmed that the fluctuations are large enough. A minimum limit to the fluctuation value for the diagnosis is specified. The diagnosis is possible only when the fluctuation is larger than the limit.
Figure 7 Example of DTM Diagnostic GUI |
The setting of the diagnostic functions and confirmation of the parameters are performed using setting tools, such as Yokogawa's Integrated Device Management Software Package PRM (Plant Resource Manager) and Versatile Device Management Wizard FieldMate5 6. Since the reference values are acquired by switching modes in the device, another measuring instrument is not required. The blockage detection is confirmed by simulating a blockage by operating the three-way valve or stop valve installed on the impulse line and generating an alarm.
Processing Procedures for Heat Trace Monitoring Diagnosis
Since the flange temperature is estimated from the capsule and amplifier temperatures, a coefficient for calculating the flange temperature needs to be obtained. The coefficient is obtained by heating the flange and measuring its temperature before diagnosis, and then the obtained coefficient and the high and low temperature alarm threshold values are set for the device.
Processing Procedures for Alarm Masking
Figure 6 shows the masking of diagnostic alarms for the HART communication type. The diagnostic results of blockage detection and flange temperature error are kept in the Diag Error parameter and the output and display of the results are determined by the Diag Option parameter. With the FOUNDATION Fieldbus communication type, the diagnostic results are kept in the DIAG_ERR parameter, and the selection and output are subject to the DIAG_OPTION parameter.
GUI FOR ADVANCED DIAGNOSTIC
Device Type Manager (DTM) of the FieldMate is equipped with a dedicated diagnostic graphic user interface (GUI) as shown in Figure 7, which facilitates the setting and monitoring of parameters for the advanced diagnosis. The GUI makes it easy to obtain a blockage diagnostic reference value, calculate the flange temperature coefficient, and select the alarm masking.
Alarm occurrences and their description can be confirmed on the Diagnostic Information screen in Device Viewer of the FieldMate. Fluctuation values and a degree of blockage can be monitored on the Trend Information screen. Figure 8 shows those screen examples. Changes in the diagnostic data caused by operating the valve can be viewed graphically when confirming the simulated blockage detection for the blockage diagnosis.
CONCLUSION
Figure 8 Examples of Diagnostic Information and Trend Information Screens in Device Viewer |
Archiving diagnostic information on the device described in this report in an application of the upper system and analyzing its long-term trend enable monitoring the tendency and performing accurate predictive diagnosis. This can be accomplished by combining the EJX series differential pressure/pressure transmitters and Yokogawa's Integrated Device Management Software Package PRM.
In order to cope with a growing number of devices and an increasing amount of information, new functions similar to those mentioned so far must be performed by the field instrument itself, and also incorporation of predictive diagnostic functions into the field instrument, improvement of the functionality and accuracy, and development of new techniques will be required in future. Yokogawa will not only respond to these requirements but also provide higher value- added solutions combining Yokogawa's system products.
REFERENCES
- Toshio Aga, "Future Technical Prospects for Field Instruments," Yokogawa Technical Report, Vol. 48, No. 1, 2004, pp. 11-12 in Japanese
- Nobuo Miyaji, Kaoru Sonoda, Hideo Akahori, et al., "Impulse Line Blocking Diagnosis of Differential Pressure Transmitters," Yokogawa Technical Report, Vol. 48, No. 1, 2004, pp. 33-36 in Japanese
- Yoshitaka Yuuki, Nobuo Miyaji, et al., "Advanced Field Diagnosis to Achieve Asset Excellence," Yokogawa Technical Report English Edition, No. 44, 2007, pp. 17-20
- Akio Itou, Shin-ichi Mimura, et al., "EJX910 Multivariable Transmitter," Yokogawa Technical Report English Edition, No. 42, 2006, pp. 13-16
- Shunsuke Hayashi, "Unified Diagnoses Management of PRM Plant Resource Manager," Yokogawa Technical Report English Edition, No. 44, 2007, pp. 21-24
- Isao Hirooka, Youji Saitou, et al., "FieldMate Field Device Management Tool for the New Era," Yokogawa Technical Report English Edition, No. 44, 2007, pp. 9-12
- EJX, PRM, and FieldMate are registered trademarks of Yokogawa Electric Corporation.
- FOU NDATION Fieldbus and HART are registered trademarks of the Fieldbus FOUNDATION and the HART Communication Foundation (HCF), respectively.
Industrias
-
Agua y agua residual
Yokogawa ha estado suministrando soluciones de control para la producción hídrica sostenible desarrollando tecnología con mayor eficiencia energética, ayudando a reducir la huella de carbono de las operaciones y fabricando productos de gran solidez que protegen el ambiente contra los contaminantes. Con nuestra tecnología de vanguardia y amplios conocimientos de las aplicaciones, trabajamos con usted para proveer soluciones hídricas sostenibles que impulsen su negocio y agreguen alto valor a lo largo del ciclo de vida de la planta. Nuestra tecnología y nuestros productos mejoran el desempeño de las plantas y garantiza que puedan operar competitivamente en los mercados del agua de hoy, así como reducir sus costos operativos. Yokogawa brinda apoyo en una amplia gama de aplicaciones para el control del agua en los mercados del agua tanto públicos como privados.
-
Bocas de pozo y separación
La boca de pozo proporciona la interfaz estructural y la presión que contiene para el equipo de perforación y producción. El control de la presión superficial es proporcionado por un ensamble de válvulas con medidores y obturadores (árbol de Navidad), que se instala en la parte superior de la boca de pozo. Las válvulas de aislamiento y los equipos de obstrucción controlan físicamente el flujo de los fluidos del pozo cuando el pozo está en producción. Varios paquetes de automatización se añaden al monitor local o remoto, controlan y optimizan la producción de cada pozo o almohadilla de múltiples pocillos. Los separadores de campos petroleros emplean un recipiente a presión para separar así los fluidos producidos en los pozos de petróleo y gas en componentes gaseosos y líquidos que se transfieren a continuación a las tuberías o almacenamiento localizados en función de la infraestructura de las zonas.
-
En cubierta
Al igual que su equivalente en tierra, el procesamiento y manejo en cubierta en las plataformas de producción preparan hidrocarburos extraídos para transportación. Yokogawa ofrece soluciones de control integrado y de monitoreo que maximizan la productividad y la disponibilidad de las operaciones en cubierta.
-
Energía
A mediados de la década de 1970, Yokogawa inició su participación en el negocio de la energía con el lanzamiento del Sistema de control eléctrico EBS. Desde entonces, Yokogawa ha continuado firmemente con el desarrollo de nuestras tecnologías y capacidades para proveer los mejores servicios y soluciones a nuestros clientes en todo el mundo.
Yokogawa ha operado la red de soluciones de energía globales para jugar un papel más activo en el dinámico mercado de energía global. Esto ha hecho un posible un trabajo en equipo más unido dentro de Yokogawa, el cual conjunta nuestros recursos globales y nuestra especialización en la industria. Los expertos en el sector de energía de Yokogawa trabajan juntos para brindar a cada cliente la solución que se adapta mejor a sus requerimientos sofisticados.
-
Energía geotérmica
La energía geotérmica puede generar un suministro estable de electricidad durante todo el año, ya que no depende de las condiciones meteorológicas. Además, como no hay combustibles que se quemen por encima del suelo y solo se liberan muy pequeñas cantidades de dióxido de carbono, es amigable con el medio ambiente. Hay abundantes recursos geotérmicos a lo largo del cinturón del Pacífico (también conocido como el "anillo de fuego"), en países como Japón, Filipinas, Indonesia, Nueva Zelanda, México, Costa Rica y Estados Unidos, así como Islandia, Turquía, e Italia que se encuentran en otras regiones de actividad geotérmica. Hasta la fecha, Yokogawa ha participado en 30 proyectos de generación de energía geotérmica en Japón, el Sudeste de Asia y otras regiones, proporcionando una variedad de tecnologías de medición y control que mejoran la confiabilidad y la eficiencia en el mantenimiento de sistemas de generación de energía geotérmica.
-
Petroquímica y a granel
Las empresas productoras de petroquímicos, productos inorgánicos o productos intermedios se encuentran bajo una presión constante para equilibrar los costos y los márgenes al suministrar productos a sus clientes de manera oportuna y eficiente, manteniendo al mismo tiempo operaciones seguras y conformes con la normativa. Además, las empresas químicas tienen que adaptarse a la constante fluctuación de los precios de los insumos y la energía y tener la capacidad de proveer al mercado la combinación de productos más rentable.
Yokogawa ha estado supliendo las necesidades de automatización del mercado de productos químicos a granel globalmente y ha obtenido reconocimiento como líder en este mercado. Con productos, soluciones y especialización en la industria, Yokogawa entiende su mercado y las necesidades de producción y trabajará con usted para proporcionarle una solución confiable y rentable durante el ciclo de vida de su planta.
-
Procesamiento y fraccionamiento
El procesamiento de gas natural está diseñado para controlar el punto de condensación del flujo de gas natural y separar los líquidos de gas natural para la venta y distribución. La eliminación de petróleo y condensados, la eliminación de agua, la separación de líquidos de gas natural y la eliminación de azufre y dióxido de carbono son procesos que se emplean para separar las impurezas en el alimentador que proviene de los yacimientos aguas arriba. En el proceso de fraccionamiento se extraen los efluentes líquidos de la planta de procesamiento de gas, que pueden estar compuestos de metano, propano, butano y pentano, para ser tratados en columnas de fraccionamiento separadas, y posteriormente pueden pasar a una planta de tratamiento de impurezas antes de ser vendidos como componentes separados.
-
Producción flotante, almacenamiento y descarga (FPSO)
La unidad de Producción flotante, almacenamiento y descarga (FPSO) es una planta de producción flotante en altamar que almacena tanto el equipo de procesamiento como los hidrocarburos producidos. Las unidades de Producción flotante, almacenamiento y descarga (FPSO) son utilizadas por las compañías petroleras para lograr que sea económicamente viable producir petróleo en zonas remotas y en aguas más profundas.
-
Refinación, procesamiento y almacenamiento de petróleo y gas
Gracias a sus innovadoras plataformas tecnológicas y su ejecución líder en la industria, Yokogawa tiene buena reputación en el mercado global como socio en soluciones pionero en la integración de tecnologías para todos los aspectos del ecosistema de petróleo y gas, desde el yacimiento hasta la empresa. Soluciones comprobadas que incluyen modelado de negocio predictivo, optimización de plantas y plataformas de automatización altamente confiables están apoyando a los operadores de refinación, procesamiento y almacenamiento a dirigir sus negocios con niveles de eficiencia óptimos. Yokogawa está ayudando a sus clientes a desarrollar sus estrategias de automatización, para garantizar años de utilización de activos altamente eficaz y sostenibilidad.
-
Submarino
Los sistemas de producción submarinos se encuentran a diferentes profundidades en el fondo del mar. A medida que se extrae el hidrocarburo, este puede ser enviado a una plataforma de producción en altamar existente, o por medio de líneas que se pueden atar a las instalaciones en tierra para su procesamiento. Varios tipos de tecnología de equipo de perforación pueden perforar los pozos, y el aceite extraído así como el gas natural se transportan a la superficie a través de un tubo ascendente. Al igual que en las instalaciones en tierra, las plataformas de producción pueden dar servicio a muchos pozos en un área grande. Los sistemas submarinos extraen y en algunos casos procesan los hidrocarburos antes del transporte.
Yokogawa ofrece soluciones integradas de control y monitoreo que maximizan la productividad del submarino, de la marina y las operaciones en cubierta mientras se mantienen en un ambiente seguro.
-
Terrestre
La industria de exploración, desarrollo y producción terrestre se enfrenta a exigencias cada vez más altas y mayores desafíos con entornos cada vez más difíciles y hostiles en las que debe funcionar.
A medida que las oportunidades de los recursos de gas natural no convencionales, en particular el gas de esquisto, están creciendo en América del Norte, la solución total de Yokogawa juega un papel importante al ayudar a los clientes a satisfacer los desafíos de reducir tanto el CAPEX como el OPEX, mientras que las tecnologías integradas mejoradas aumentan la producción. Nuestra experiencia global y local constituye la base de nuestras soluciones totales únicas para satisfacer las necesidades de esta industria. Con expertos en exploración, desarrollo y producción terrestre que trabajan en oficinas por todo el mundo, ofrecemos un soporte rápido y extenso para satisfacer las demandas de nuestros clientes.
Productos y Soluciones Relacionadas
-
EJX110A
Transmisor de Presión Diferencial con montaje tradicional basado en la serie EJX-A.
-
EJX118A
Transmisor de Presión Diferencial con Sellos Remotos de Diafragma basado en la serie EJX-A.
-
EJX210A
Los Transmisores de Presión Diferencial Montados en Brida diseñados para aplicaciones de Nivel Líquido de la serie EJX-A.
-
EJX438A
Transmisor de Presión del Manómetro con Sello Remoto del Diafragma basado en la serie EJX-A.
-
EJX440A
Transmisor de Alta Presión del Manómetro con montaje tradicional basado en la serie EJX-A.
-
EJX530A
Transmisor de Presión del Manómetro Montado en Línea basado en la serie EJX-A.
-
EJX630A
Transmisor de Alta Presión del Manómetro Montado en Línea basado en la serie EJX-A.
-
EJX910A
Este transmisor mide con precisión la presión diferencial, la presión estática, y la temperatura del proceso; además utiliza estos valores en un ordenador de flujo de alto desempeño para ofrecer Flujo Másico que está compensado.
-
EJX930A
Está diseñado específicamente para aplicaciones de alta presión estática, este transmisor mide con precisión la presión diferencial, la presión estática, y la temperatura del proceso; además utiliza estos valores en un ordenador de flujo de alto desempeño para ofrecer Flujo Másico que está compensado.
-
Transmisores de Presión
El proceso de medición preciso y estable de los transmisores de Presión de Yokogawa son la base de la operación rentable, segura y confiable de su planta.