전자유량계 CA Series는 다른 전자유량계로 측정하기 어려운 유체를 측정할 수 있습니다. 예를 들어, 고농도 슬러리(High-concentration slurry) 유체, 점착성(Insulator-adhesive) 유체, 초저전도성(Ultra-low-conductivity) 유체 등이 있습니다.
CA Series는 'Total Insight' 컨셉으로 디자인되었으며, 도트 매트릭스(Dot matrix)와 백라이트(Backlight)로 인해 디스플레이의 가시성이 우수합니다.
또한, 검증 기능을 사용하면 장비를 진단하고 장비 상태를 쉽게 확인할 수 있습니다.
전자유량계 CA Series
CA Series는 슬러리(Slurry) 유체와 점착성(Adhesive) 유체와 같이 측정하기 어려운 유체에도 안정된 측정을 제공합니다.
'Total Insight' 컨셉을 기반으로 고객들의 작업용이성과 유지보수성을 향상시킵니다.
Details
About Magnetic Flowmeters CA Series
The CA Series is the successor to the ADMAG CA series.
The sensor structure inherits the structure of ADMAG CA.
The transmitter has evolved with the design of the Total Insight concept.
Sensor Structure
Structure That Can Be Measured Even in Highly Concentrated Slurry or Insulator-Adhering Fluids
- Electrodes not in contact with fluid
- High-purity alumina ceramics measuring tube
Slurry Fluids
Stable Measurement Is Possible Even in Fluids Containing Slurry Such as Latex and Calcium Carbonate
The CA Series electrode is structured so that it does not come into contact with the fluid. The highly concentrated slurry fluid does not come into contact with the electrodes. Therefore, electrical noise generated by contact between the slurry and the electrode is not physically generated.
Adhesive Fluids
Stable Measurement Is Possible Even for Fluids Containing Insulators Such as Waste Fluids and Red Mud
The surface of the ceramic measuring tube is smoother (Ra 1.6) and has a structure that prevents insulation from sticking to it. Even if an insulator adheres, the CA Series has no effect on measurement because of the measurement principle of the capacitive equation.
Ultra-Low Conductivity Fluids
Ultra-Low Conductivity Fluids Such as Pure Water Can Be Measured
Capacitive electrodes and high impedance circuits make it possible to measure ultra-low conductivity fluids.
Since the electrode is installed as a face electrode on the outside of the ceramic pipe, which is a measuring tube, the signal electromotive force is detected through the capacitance of the tube wall. In addition, the adoption of high-frequency excitation and the realization of a high-impedance circuit at the signal input make it possible to reliably detect fluid electromotive force with minimal effect of fluid noise.
* If the diameter is 100 mm or less, span error may occur when measuring fluids with conductivity of 0.1 µS/cm or less. Please consult us for fluid measurements with a conductivity of less than 0.1 µS/cm.
Easy Replacement
Customer Piping Can Be Replaced Without Modification
The lay length between the CA Series and ADMAG CA are the same. Therefore, there is no additional cost for customer plumbing.
Total Insight
From Sensing to Sensemaking
- A common product concept for flowmeters that assist customers throughout the product lifecycle.
- Helps customers reduce operating costs throughout their entire product lifecycle.
- Solve your problems with outstanding technology and field domain knowledge.
* The CA Series is a flowmeter designed by Total Insight's design concept.
Total Insight - Simplified Selection -
HART Communication
Improved connectivity with host devices
By supporting the world standard HART communication, it is easy to achieve uniform communication protocols for the entire plant. Uniform protocols also improve maintainability.
Total Insight - Smart Assist -
Wizard Function
Simple and easy setup by following the Wizard function on the display
Frequently used parameters can be set via a wizard function. Even first-time users can follow the flow and set it up with intuitive peace of mind. Setting time is also reduced because the set parameters are downloaded together to the device.
Multiple Languages
Information can be checked in the language most suitable for the user
The language of the display unit can be selected from 9 languages. By displaying the optimal language for the user, it is possible to check the display information accurately in a short time.
* Available Languages: Japanese / English / Chinese / French / German / Italian / Spanish / Portuguese / Russian
Transmitter Wiring Terminal
Choice of the Clamp type or M4 Screw type
Both clamp and screw types boast high reliability. The clamp type takes about half the wiring time as the screw drive.
Total Insight - Process Guard -
Dot Matrix Display / Backlight
A lot of information can be checked at a glance, visibility has also improved
The display is a dot matrix 4-line display. Even if the device is installed in a dark place, the information can be confirmed by the backlight, and the visibility is excellent.
* 64 x 128 dot LCD
Data Logging Function
Device itself acquires process data
Data is acquired on the built-in microSD card, so no other devices need to be prepared. You can understand the situation before and after a malfunction occurs, which enables quick troubleshooting. Up to three data points can be logged simultaneously.
Total Insight - Expert Solution -
Verification Function
Anyone Can Use a Unified Tool to Check Equipment Health
With the verification function, there is no need to remove the flowmeter from the piping during maintenance. Diagnostic results are generated as reports.
The verification function is broadly divided into standard verification and extended verification.
* To use the verification function, please purchase the following together.
- Mobile Field Device Management FieldMate
- FSA130 Magnetic Flowmeter / Vortex Flowmeter Verification Tool
Available microSD Card
Data copy time from microSD card to device is only 1 minute
Parameters set for the device can be saved on a microSD card. Parameters saved in microSD can be copied to another device and set.
It takes about 30 minutes to set the parameters manually. On the other hand, if you copy the parameters from the microSD, the setting will be completed in about 1 minute, leading to a 97 % reduction.
Multiple Inputs and Outputs
Flexible Input and Output According to Application
Up to four input and output signals can be selected.
자료실
The use of recycled oil as an energy source presents a significant processing problem. ADMAG CA has been shown to provide reliable and stable flow measurement of recycled oil containing water.
Downloads
Brochures
Instruction Manuals
General Specifications
Software
2D/3D Configurator
기술 및 솔루션, 요꼬가와에 대한 자세한 정보를 찾고 계십니까?
견적 및 기술문의