Monitoring Temperature and Humidity

다운로드 (274 KB)

Overview

Monitoring Temperature and Humidity

Applying the DX's mathematical functions, humidity is calculated using the dry bulb and wet bulb formulas based on input from a resistance temperature detector (Pt). The calculation follows the Perunta formula.

Customer Needs

  • To have the humidity calculation function be internal to the DX, since we want to monitor humidity along with the internal temperature of the environmental testing equipment
  • To use general purpose RTDs rather than specialized humidity sensors, and avoid depending on external instruments and complicated programming

Process Outline

Signals are input from Pt type RTD sensors. Dry and wet bulb temperature are measured with the Pt's, and the DX's calculation function automatically calculates humidity based on the measured values. The calculation is based on the Perunta formula, and the multipliers in the formula are input ahead of time as Kxx. Dedicated humidity sensors or external computing units are not needed to determine the humidity, resulting in reduced costs and more compact instrumentation. The number of instruments comprising the system is also reduced, resulting in higher overall reliability. Sensors can be hard to calibrate due to the difficulty of creating a reference humidity. The DX overcomes this problem because humidity is determined through a calculation, and calibration of the input can be substituted with calibration of the Pt100ohm range.

Input: Pt100 (or JPt100)
CH1: dry bulb°C), CH2: wet bulb°C)
Computed result: Humidity displayed on CH37 (MATH channel)
Expressions and constants: Perunta formula
31: 1+K9
32: 2+K9
33: EXP(K1/31+K2+K3*31+K4*31*31+K5*LOG(31))
34: EXP(K1/32+K2+K3*32+K4*32*32+K5*LOG(32))
35: 33*K10
36: 34*K10
37: ((36-K6*K7*(K11+2/K8)*(1-2))/35)*K10
K01: -6096.9
K02: 16.636
K03: -0.027112
K04: 1.674E-5
K05: 5.6033
K06: 0.0012 (ramda)
K07: 1.0133E+5
K08: 610
K09: 273.15
K10: 100
K11: 1
K12: 2
  K06 (ramda) value is set as follows
When wind speed is 0-0.5 m/s: 0.0012
When wind speed is 1-1.5 m/s: 0.0008
When wind speed is 2.5 m/s or higher: 0.000656

Yokogawa's Solution

DX Series Paperless Recorders can easily calculate humidity using RTDs

  • Humidity calculated with a MATH function (optional)
  • Measured and calculated results saved electronically to local media while being displayed in real time on the large, color TFT display
  • Enables data sharing on the network (Ethernet compatible)

Conclusion

DX Series Paperless Recorders
DX

DX series instruments allow you to determine temperature and humidity and manage the results as manufacturing/quality data at a reasonable cost with a simple configuration. No special external equipment or humidity sensors are required, resulting in overall cost reductions in the system.

 


 

업종

  • 업스트림

    업스트림(Upstream) 산업에는 유전 또는 해저의 원유 및 천연가스의 채취 및 생산을 위한 유정제어, 증류, 분리 및 제품 완성을 포함한 해상 및 육상 플랜트가 포함됩니다.

    석유는 육상으로 옮겨져야 하는 관계로 운송 전에 분리 작업이 필요합니다. 1차 및 2차 분리 단계는 일반적으로 가스 흐름, 물 흐름 및 오일 흐름의 3단계로 분류됩니다. 가스 이동은 파이프라인을 필요로 하며, 이동하기 전에 상류 공정에서 분류 공정을 거치게 됩니다. 액체는 탱크 또는 파이프라인에 넣고 운송을 하므로 정확한 레벨 측정이 가능한 레벨계가 필요합니다.

    See More
  • 오일 및 가스

    Yokogawa는 해상 및 육상 시설에서 파이프라인, 터미널 및 심해 운전에 이르기까지 석유 및 가스 사업의 모든 부분에서 풍부한 경험을 보유하고 있습니다. 우리는 안전을 강화하고 정확하고 신뢰성 있는 운전을 보장하며 플랜트 효율을 높이는 솔루션을 제공합니다.

    See More
  • 해상플랜트 (FPSO FLNG & FSRU)

    해상 탐사 및 생산에는 열악한 조건 아래 최대의 가동 시간이 요구됩니다. 유인 및 무인 시설에서는 신뢰성이 확보된 원격 모니터링 기능을 갖춘 안정적인 통합제어 및 안전시스템 (ICSS)이 필요합니다. Yokogawa는 모든 규모 및 복잡한 자동화 단계의 해양프로젝트를 수행하는 데 있어 최첨단 기술과 광범위한 경험을 보유하고 있습니다.

    See More

Related Products & Solutions


Top