Introduction
Hot Blast Stove Process |
Measurement of O2 Concentration in Hot Blast Stoves Essential to Improving Combustion Efficiency
In a hot blast stove, the by-product gas produced in a coke oven is burned to preheat the air blast for the blast furnace. To improve the combustion efficiency and conserve energy in a hot blast stove, it is essential to be able to control combustion by measuring and adjusting the oxygen concentration in the exhaust gases.
The ZR22G/ZR802G Direct In-Situ Zirconia Oxygen Analyzer is ideally suited for combustion control in hot blast stoves. It utilizes a long-life sensor.
Expected Benefits
- Improves combustion efficiency in hot blast stoves
- Ensures stable, continuous oxygen measurement
- Reduces operating costs
- Minimizes the need for equipment replacement
Process Overview
The temperature of the hot blast used in blast furnaces has been increasing every year and currently stands at around 1300°C. Under such circumstances efficient operation is achieved by such measures as increasing the calorie value of fuel gas, replacing the hot blast furnace more frequently, and recovering waste heat from gas. To further improve combustion efficiency and save energy, measurement of the oxygen concentration in exhaust gases is required.
Solution Details
Field Data
Process Conditions
Measurement: | 20 to 350 ℃ |
---|---|
Pressure point: | Duct |
Temperature: | 3.5 to 10 kPa |
Dust: | 50 mg/Nm3 |
Fuel: | Gas |
Measurement System
Detector: | ZR22G-015-S-Q-E-☐-☐-E-A /CV/Z |
---|---|
Z: | Glove box option |
Converter: | ZR802G-☐-☐-N-N /☐ |
Flow setting unit: | ZA8F-☐*C |
Pressure regulator: | G7013XF or G7014XF |
Case for calibration gas cylinder: | E7044KF |
Note: the calibration gas cylinder must be purchased locally
Utilities
Rated voltage: 100 to 240 V AC
Rated frequency: 50/60 Hz
Power consumption: 330 VA (Max. 800 VA)
Instrument air (reference gas) pressure: 300 to 700 kPa
Notes
- The detector is installed in a glove box to reduce the sample gas pressure.
- When more than three detectors are installed, it is recommended that the AV550G Averaging Converter be used instead of the ZR802G converter. The AV550G accepts signals from up to eight detectors.
업종
Related Products & Solutions
-
Multi Channel Oxygen Analyzer System ZR22/AV550G
AV550G 멀티 채널 산소 분석계 시스템은 최대 8개의 ZR22 프로브를 동시에 측정할 수 있습니다. ZR 프로브의 in-situ 측정 방법은 프로세스 컨디셔닝이나 샘플링이 필요하지 않습니다. 이를 통해 유지보수 비용을 절감하고 공정 변화에 대한 측정 속도를 높일 수 있습니다.
-
지르코니아식 산소/습도 분석기 ZR22G, ZR802G
이 장비는 고온에서 산소 및 습도 측정이 가능하며 매우 정교한 지르코니아 센서가 장착된 ZR22G 검출기와 디지털 통신 및 데이터 로그 기능을 갖춘 변환기 ZR802G로 구성됩니다. ZR22G 및 ZR802G는 샘플링 장치 없이 연속적으로 측정할 수 있습니다. 센서의 성능을 자가진단하고 (교정 가스를 사용하지 않음) 현장에서 Heater assembly를 교체하여 유지 보수를 용이하게 하여 작업 비용을 줄일 수 있습니다.
-
Oxygen Analyzers
산소 분석계는 연소 제어, 공정 품질, 안전 및 환경 응용 분야에서 중요한 측정을 제공합니다.