In the fertilization and early embryonic development process, various events are spatiotemporally controlled, and many events are connected in the cause-effect relations toward the final goal of ontogenesis. To understand the mechanism of this process, conventional experimental techniques by fixing and destruction of the cells have limitations. If this process can be observed over time and the development process can be continued after the observation, it will open a new era in the Genetics research. A mammalian developmental biology researcher, Dr. Kazuo Yamagata, established such technique by using the CSU system.
He successfully imaged mouse embryos over a long period of time, from the post-fertilization through to the blastocyst stage, to acquire approximately 60,000 of 3D confocal images. Thereafter, the embryos were transferred to a recipient mouse, and the pups were born all normally, grew healthy, and were capable of reproduction; a firm evidence that this early embryo imaging technique does not adversely affect the process of full-term development. The high speed image acquisition and extremely low excitation light unique for the CSU system enabled greatly reduced phototoxicity and realized intensive but damage-free long time observation. Only by using this technology which does no harm on the embryonic development, it is possible to “utilize the same embryo after intensive analysis by imaging” , and thus to investigate cause- and-effect relationship of various early stage phenomena and their influence on the development.
Figure : The long-time, multi-dimensional live cell imaging on early stage embryos does not affect the process of ontogenesis.
(a) Experimental flow
(b) Movie example: Images were acquired at 7.5-minute intervals over approximately 70 hours.
This figure shows extracted images at 2-hour intervals.
Each image is the maximum intensity projection of a total of 51 images in the Z-axis direction.
Green:Spindle (EGFP-α‒tubulin), Red:Nucleus (H2B-mRFP1)
Experimental conditions | |
Total time | 70 hours |
Interval | 7.5 min/stack |
Z-axis slices | 51 sections (at 2μm intervals) |
Channel | 3(DIC, EGFP, mRFP1) |
Position | 6(Total 72 embryos) |
Laser power(Measured at objective lens) | 488nm (0.281 mW), 561nm (0.225 mW) |
Data: Kazuo Yamagata, PhD., Laboratory for Genomic Reprogramming,Center for Developmental Biology, Riken
Our Social Medias
We post our information to the following SNSs. Please follow us.
Follow us | Share our application | |
@Yokogawa_LS | Share on Twitter | |
Yokogawa Life Science | Share on Facebook | |
Yokogawa Life Science | Share on LinkedIn |
Yokogawa's Official Social Media Account List
Related Products & Solutions
-
High Speed
The CSU-X1 is widely recognized as the leading tool for live cell imaging with 2,000 fps capability.
-
Wide Field of View
The CSU-W1 is our answer to researchers’ requests for “Wider FOV” and “Clearer Images”.
-
Life Science
Unlocking Life with Precision
Yokogawa는 단순히 측정하는 것을 넘어, 극한의 정밀도를 자랑하는 측정을 통해 연구의 질을 높입니다. 이는 마치 현미경으로 미세한 세포를 관찰하듯, 연구 대상을 더욱 정밀하게 분석하고 이해하는 데 도움을 줍니다. 새로운 약물 후보 물질의 효과를 정확하게 평가하고 부작용을 최소화하는 데 기여합니다. 생산 과정에서 발생할 수 있는 미세한 변화를 빠르게 감지하여 품질을 유지하고 생산성을 향상시킵니다.
-
Spinning Disk Confocal
듀얼 스피닝 디스크 기술의 선구자인 Yokogawa의 공초점 스캐너 장치는 광학 현미경을 변형시켜 실시간 라이브 셀 이미징 기술을 구현합니다.