µR10000 & µR20000

Industrial and laboratory environments require rigorous and continuous monitoring during manufacturing process. Yokogawa's μR series strip chart recorder provides accurate high resolution measurement charts that can withstand harsh production environments. The μR series can be used as a monitoring device as well as quality control instrument in many applications such as pharmaceutical, chemical, power generation, heat treat and environmental monitoring.

Details

Carries over the features of the Number One Industrial Recorders

  • Carryover of the µR1000/µR1800
  • Bringing you the highest reliability
  • Large VFD, Easy to Read
  • Navigational Display
  • Internal Illumination and New Chart Cassette
  • Powerful Math Functions
  • Variety of Networking Functions
  • Application Software
  • A Free Software Upgrade
  • A Wealth of Recording and Printing Functions
  • Adding New Functions
    (Calibration Correction, 24 VDC/AC Power Supply, Portable Type)

Retains the Same Powerful Specifications of the μR1000 and μR1800

Pen and plotter pens Ribbon cassette
Pen and plotter pens Ribbon cassette

Bringing You the Highest Reliability

Servo Unit

Servo Unit

µR10000

The pen servo unit takes advantage of an ultra-small, rack-and-pinion stepping motor. The servo unit is smaller and consumes less power than previous models.

Splash-proof Front Door (conforms to DIN 40050-IP54)

Splash-proof Front Door (conforms to DIN 40050-IP54)

µR10000

The front door meets DIN 40050-IP54 standards in panel-mount installations.

High-Voltage Solid State Scanners

High-Voltage Solid State Scanners

High withstand voltage semiconductor relays have been adopted for scanners that switch the input signal. They enable high speed scanning of six dots per second, increase the life of the scanner, and reduce noise.

Use of ASICs

Use of ASICs

The recorders feature a high degree of functional integration through Yokogawa's renowned ASICs (application specific integrated circuits, or custom ICs). They allow for reduced power consumption, increased lifespan of components, and suppressing of heat emmisions.

Safety/EMC Standards

Safety/EMC Standards

EMI testing LAB in Yokogawa

Yokogawa's highly reliable industrial recorders support safety and EMC (electromagnetic compatibility) standards. And of course, the µR conforms to the European CE marking standard.

Lightweight

µR10000

µR10000

*Individual terminals are removable, making wiring and maintenace easy.

µR20000

µR20000

*Individual terminals are removable, making wiring and maintenace easy.

Large VFD

Uses a large, easy-to-view VFD 101 x 16 (µR10000), 181 x 16 (µR20000) full dot matrix display. All settings are interactive, and supported by the navigational display, offering easier to read selections and superior ease of operation.

Multi-Display (Displays a Variety of Screens) for Site Monitoring

"I want to use my recorder as a monitor."
µR10000 - 6 channel digital display (6 dot model) µR20000 - 12 channel digital display (12, 18, and 24 dot models)
µR10000 - 6 channel digital display (6 dot model) µR20000 - 12 channel digital display (12, 18, and 24 dot models)
2 channel digital display 4 channel digital display
2 channel digital display 4 channel digital display

"I want to monitor the recorder position on an analog indicator."

µR10000 Flag display µR20000 Flag display
µR10000 Flag display µR20000 Flag display

"I want to monitor alarms collectively."

µR10000 Channel alarm status display µR20000 Channel alarm status display
µR10000 Channel alarm status display µR20000 Channel alarm status display

Navigational Display Makes Setup a Snap

All settings are interactive, and supported by the navigational display, offering superior ease of use.

Navigational Display Makes Setup a Snap

µR10000 Navigation Display
(Example of Range Setting)

Upper (setting parameter): The setting channel, range, span (left), or span (right) is displayed.
Lower (setting navigation): An explanation and setting range for the parameter is displayed.

µR10000: scrolls for 18 characters or more
µR20000: scrolls for 31 characters or more

This µR reflects advances in the chart cassette and internal illumination. Also, our new disposable pen (pen model), plotter pen, cassette ribbon (dot model), and chart paper maintain compatibility with previous models.

μR plotter pen

By using a high intensity white LED and light-diffusing rod for the internal illumination, the visibility of the chart section has been greatly increased.

Chart Cassette

The chart cassette is equipped with a chart-ejection function. You can write memos on the chart and check the historical trend during recording.

µR10000 Chart Cassette µR20000 Chart Cassette
µR10000 µR20000

Powerful Math Functions (/M1 Option) 

Powerful Math Functions (/M1 Option)Analog recording of computed results

Dot model:
Allows recording on all computation channels (12 ch). Recording can be turned ON/OFF on each channel. 

Pen model:
You can assign measured or computed results to an arbitrary pen for recording.

 

 

 

Computation channels Uses measurement channels, communication digital input, and remote input.
No. of computation channels Pen models: 8ch
dot models: 12 ch (µR10000), 24 ch (µR20000)
Computations The four arithmetic operations (+, -, ×, ÷), square root, absolute value, common logarithm (y=log10x), exponents (eX), and powers.
Relational operators (<, >, ≤, ≥, =, ≠)
Logical operations (AND, OR, NOT, XOR)
Constants 30
Communication digital input Pen: 8 points, Dot: 12 points (µR10000), 24 points (µR20000)
Remote input Up to 5 remote inputs allowed.
Remote status (0/1) can be used in equations.
Equations Up to 120 characters can be used
Statistical computations MAX, MIN, AVE, SUM, MAX-MIN

Variety of Networking Functions

Variety of Networking Functions

A Wealth of Recording and Printing Functions

Printing Example

µR10000

4 pen model 6 dot model
4 pen model 6 dot model

µR20000

24 dot model

24 dot model

notes Note

 

Partial expanded recording

Zone recording

Partial expanded recording
Any important portion within the full scale can be expanded for recording.
Zone recording
Recording areas (zones) for each channel can be recorded separately.

Calibration Correction (Option, /CC1)

This function enables minute adjustments when a certain correction is necessary due to deterioration of a sensor, or if measured values fall within the accuracy range but fluctuate relative to the displayed values on other instruments. Input signals are corrected based on a specified broken line, and its values are measured.

Number of Set Points
You can select the number of points that make up the segments (including the start and end points) in the range of 2 to 16. 

Using revision values
Using revision values

Using absolute values
Using absolute values 
Corrected value (B4) of the fourth set point = a ? b

Example of the Input Values

Input Value Corrected Value Revision Value Absolute Value
9.8° 10.0° 0.2° 10.0°
90.5° 90.0° -0.5° 90.0°

24 VDC/AC Power Supply (Option, /P1)

The unit can be powered under 24 VDA or 24 VAC.

  • Rated power supply: 24 VDC/AC
  • Allowable power supply voltage range: 21.6 to 26.4 VDC/AC
  • Dielectric strength:
  • Power supply to ground terminal: 1000 VAC
  • Power consumption (approx.): 
Supply Voltage Max.
24 VDC Approx. 50 VA
24 VAC (50/60 Hz) Approx. 60 VA

Portable Type (Option, /H5[ ] )

This model comes with a convenient carrying handle and portable power cord. 

Names of Parts

Names of parts Names of parts
µR10000 µR20000
  1. Carrying handle
  2. Protective ground terminal (spare)
  3. Power terminal with protective ground terminal (attache the specified power cord)
  4. Feet (four)

Specifications

specifications

Header Printout (Option, /BT1)

Manufacturing process information such as batch/lot number and comments can be printed out in synchronization with analog recording.

Example Printout (Pen Model)

Example Printout (Pen Model)

*With the µR series, computed value can be included.

Notes:

  • Bach name = batch number (characters)- lot number (4 or 6 digit number)
    Example)
    Batch number - 000001
    batch number   lot number (you can automatically increment by 1 when recording stops.)
  • Start printout/End printout: Printout operates like manual printout (stopped during analog recording).
  • Message printout: During analog recording, you can print out messages that include measured* values.
    (Measured* values, message strings, and date/time can be set arbitrarily.)

Basic operation

  • When you start recording, the Start printout is performed.
  • When you stop recording, the End printout is performed.
  • During analog recording, you can print out messages that include measured* values.

This basic operation pattern is shown in the figure below.

Basic operation pattern

Basic operation pattern

*With the µR series, computed value can be included.

ns-mr-21-1.png
ns-mr-21-2.png
  • SD card (up to 32 GB) enables long-duration recording
  • Provides backup and recall if chart data is lost due to paper jams or ink problems
  • Save main unit settings such as input ranges and alarms to SD card for reuse when replacing or adding instruments.

Erőforrások

Áttekintés:

The Japan Steel Works, LTD., Muroran Plant uses the Control and Measurement Station CX2000, UP series program controllers, and UT series digital indicating controllers for operation of its heat treating furnaces.

Iparágak:
Áttekintés:

Environmental data (water quality, amount of flow) is measured on-site and monitored from an office.

Alkalmazási megjegyzések
Áttekintés:

Measures temperature and vibration of the turbine for rapid identification of abnormalities.

Iparágak:
Áttekintés:

By using the computation function of the SMARTDAC+ series Paperless recorder GX/GP, computation option computes the "F-value," or sterilizing value for the sterilization process, so that the computation results can be recorded in the form of data.

Iparágak:

Downloads

További információkat szeretne a munkatársainkról, technológiánkról és megoldásainkról?

Kapcsolatfelvétel

Tetejére