The D Series is DCS-supported signal conditioners, consisting of modular type signal converters with versatile I/O specifications and housing nest. Our complete line of conditioners work well for a large or small scale systems and provide a simple platform for use and maintenance. Mounting nest conforms with JIS and EIA specifications.

HART communication

Details

  • Mixed mounting of Electronic and Pneumatic signal conditioners
    Mixed mounting of Electronic, Electronic-Pneumatic and Pneumatic-Electronic converters are available. Up to 16 converters can be mounted in one nest.
  • Relaying HART communication signals
    Bi-directional relay of HART communication signals is possible while the field devices and the DCS are isolated from each other.
  • BRAIN Communication function
    Equipped with communication functions, the conditioner allows such tasks as parameters setting, and monitoring to be done using a DCS (Yokogawa CENTUM-XL, µ-XL, etc.), PC (with VJ77 PC-based parameters setting tool).
  • Standard second output
    A second output terminal on the front panel is available as standard for output to external recorders, indicators, alarm units, etc.
  • Maintenance can be performed in the field without removing wiring or disturbing other loops.
  • Manual backup for control output (DME, DMP)
    Backup connector for model SPBD Standby Manual Station is equipped, allowing the converter to be maintained without interrupting the control output signals during operation.
  • Upper level communication
    By installing a DSC2 communication interface module, the D series signal conditioners can communicate with a PC or PLC.
Construction Nest-mounting type (up to 16 units of conditioners and mounting nest)
Mounting Method: Rack mounting (JIS/EIA specifications 19") or wall mounting
Connection Method: M4 screw terminal (for input/output, communication, power supply and grounding)
Connecting cable (Yokogawa model: KS2)
Air supply: Rc 3/8 (PT 3/8) female (2 points)
External Dimensions: 145×482.6×120 mm (H×W×D)
Power Requirements: 24 V DC±10%

Nests for mounting

Signal Conditioners

Model Product Name Input Type Output Type Descriptions
DA7 Distributor (with HART Communication) 4 to 20mA DC, from 2-wire type transmitter Output 1: 4 to 20mA DC Bi-directional relay of HART communication signals is possible while the field devices and DCS are isolated each other.
DC7 Output Isolator (with HART Communication) 4 to 20mA DC Bi-directional relay of HART communication signals is possible while the DCS and field devices are isolated each other.
DA1 Distributor 4 to 20 mA DC, from 2-wire type transmitter Output 1: 1 to 5 V DC
Output 2: DC Voltage or DC Current
 
DA5 Distributor (with Square Root Extractor) Field configurable
DA9 Distributor (Non-isolated) Output 1: 1 to 5 V DC Non-isolated output
DA2 Distributor (with Communication Function) Output 1: 1 to 5V DC
Output 2: 1 to 5 V DC
BRAIN Communication via DSC/DSC2 card.
DA0 Output Isolator (Voltage Input/ Current Output Type) 1 to 5 V DC Output 1: DC Current 1500 V AC (1 min.) of withstand voltage for output signal.
DC0 Output Isolator (Current I/O Type) 4 to 20 mA DC Output 1: 4 to 20 mA or 10 to 50 mA DC
DH0 Output Isolator (Voltage I/O Type) 1 to 5 V DC Output 1: DC Voltage
DH1 Isolator DC Voltage or DC Current Output 1: 1 to 5V DC
Output 2: DC Voltage or DC Current
Fixed range
DH2 Isolator (Free Range Type) Free range Field configurable
DH5 Isolator (with Square Root Extractor) 1 to 5 V DC Field configurable
DM1 Isolator (mV Input Free Range Type) DC mV Signal Field configurable
DR5 RTD Converter (Free Range Type) Resistance Temperature Detector (RTD) Output 1: 1 to 5 V DC
Output 2: DC Voltage or DC Current
Field configurable
DT5 Thermocouple Converter (Free Range Type) Thermocouple Field configurable
DS1 Potentiometer Converter (Free Range Type) Potentiometer resistance (3-wire type) Output 1: 1 to 5 V DC
Output 2: DC Voltage or DC Current
Field configurable
DP1 Pulse Repeater Contact Pulse, Voltage Pulse or Current Pulse Output 1: Open collector
Output 2: Open collector
Pulse rate fixed in 1:1
DP3 Pulse to Analog Converter Output 1: 1 to 5 V DC
Output 2: DC Voltage or DC Current
Field configurable
DQ0 Analog to Pulse Converter 1 to 5 V DC or 4 to 20 mA DC Output 1: Open collector Field configurable
DG1 PT Converter (R.M.S.) AC Voltage from PT Output 1: 1 to 5 V DC
Output 2: DC Voltage or DC Current
R.M.S. conversion
DB1 CT Converter (R.M.S.) AC Current from CT R.M.S. conversion
DD1 Tachometer Converter AC Voltage from tachometer Mean value conversion
DF1 Pneumatic to Electrical Converter Pneumatic Signal Output 1: 1 to 5 V DC
Output 2: DC Voltage or DC Current
Input signal range: 0.2 to 1.0 kg/cm2, 3 to 15 psi or 20 to 100 kPa
DF0 Electrical to Pneumatic Converter 1 to 5 V DC or 4 to 20 mA DC Pneumatic Signal
DSK Limit Alarm DC Voltage or DC Current 2 Relay Contacts 2 alarm outputs (N.O. or N.C. configurable)
DSC Communication I/F Card BRAIN Communication  
DSC2 Communication I/F Card BRAIN/RS485 Communication (Changeable) Applicable baud rate: 600 to 9600 bps.
DX1 Input/Output Thru Card Input resistance: 250 ohm (input type 2 only) Converts 4 to 20 mA DC signal to 1 to 5 V DC signals

Recursos

Descripción General:

HART communication is a means of transmitting multiple signals by superimposing long-standard 4-20 mA DC analog signals on digital signals. The figure below is an example of connecting field instruments and upstream devices using HART communication compatible VJA1/H signal conditioners.

Industrias:
Descripción General:

Depending on the importance of the process control system, individual isolation, duplexing, or other measures may be needed to increase its reliability. The D series signal conditioners offers DCS supporting input/output nests for connecting to upstream DCS input/output modules. 

Preguntas Frecuentes
What are the merits of conditioner nests?
(ns-faq-juxta-11008-select)
Preguntas Frecuentes
Preguntas Frecuentes
Preguntas Frecuentes
What are the merits of plugin conditioners?
(ns-faq-juxta-11007-select)
Preguntas Frecuentes
Preguntas Frecuentes
Can I change the burnout operation?
(ns-faq-juxta-11001-spec)
Preguntas Frecuentes
Preguntas Frecuentes
How do I change settings?
(ns-faq-juxta-11006-setting)
Preguntas Frecuentes
Preguntas Frecuentes
Preguntas Frecuentes
What does response speed **ms(10-90%) mean?
(ns-faq-juxta-11019-other)
Preguntas Frecuentes
What is the output on burnout?
(ns-faq-juxta-11023-spec)
Preguntas Frecuentes
What happens on a "burnout OFF"?
(ns-faq-juxta-11024-spec)
Preguntas Frecuentes
Preguntas Frecuentes
Preguntas Frecuentes
Preguntas Frecuentes
Preguntas Frecuentes
What does "time constant" mean?
(ns-faq-juxta-11021-term)
Preguntas Frecuentes
Preguntas Frecuentes
Preguntas Frecuentes

Descargas

Especificaciones Generales
Planos

¿En busca de información adicional sobre Yokogawa Iberia, tecnología y soluciones?

Contáctenos

Top