Introduction
Most zinc are produced at hydrometallurgically, where a high-grade zinc product can be obtained and valuable metals mixed in the raw material can be recovered. In the hydrometallurgy, the raw material of zinc concentrate is roasted and then dissolved in sulfuric acid to remove impurities. The process called leaching and pH control of the leachate is important. The leachate contains gypsum and impurities that may cause scaling on electrodes. As a result, it interfered with stable pH measurement and required frequent cleaning at least once a week. A pH analyzer with air jet cleaning system provides continuous cleaning and therefore can reduce maintenance frequency to once every one or two months.
Expected Benefits
- Ensures stable and continuous pH measurement
- Reduces operating costs
- Eliminates manual cleaning work by hand
Process Overview
Roasted concentrate sent from a roasting furnace, is dissolved in diluted sulfuric acid (spent electrolyte) in a dissolving tank.
ZnO + H2SO4 -> ZnSO4 + H2O
In addition, some iron and other material contained in the calcine are dissolved. Therefore, these impurities are removed by precipitation by adding manganese, lime or other additives.
FeO + Additive -> Fe2O3 (precipitation)
pH control is important to allow zinc to dissolve fully and impurities to precipitate maximally. The leachate is filtered by a filter press to remove impurities and the filtrate is fed to an electrolytic bath where zinc is electrolytically produced.
Electrolytic Zinc Manufacturing Process
Solution Details
Measurement system
4-wire pH measurement system (with jet cleaning system) | |
---|---|
Sensor | KCl refillable pH sensor (Teflon liquid junction) PH8EFP-□□-TN-TT1-N-G*A/TF |
Holder | Submersion type holder with jet cleaning system PH8HS-PP- □□ -T-JT-JP*A/MS3 |
Terminal box (when needed) | WTB10-PH3 |
4-wire pH/ORP converter | FLXA402-A-B- □□ -P1-NN-A2-WR- □ - □ -N-NN/UM |
Utilities
FLXA402 4-Wire Converter | |
---|---|
Power supply | 90 to 264 V AC, 50/60 Hz |
Power consumption | 35VA maximum |
Submersion holder | |
Air for jet cleaning | |
Air pressure | 200 to 400 kPa |
Consumption | 100 to 300 NL/min |
Notes
- Continuous air jet cleaning
Since the leachate is a strongly acid solution, its pH value is not affected by air cleaning. This allows measurement and cleaning simultaneously. - Other applications
This cleaning system can be used for other smelting processes of copper, manganese, sadmium, etc.
Field Data
Process condition
Measurement point: | Leachate in the dissolving tank |
---|---|
Temperature: | 80°C |
pH value: | pH 1.5 ± 0.2 |
Zinc: | Approx. 160 g/L |
Sulfuric acid: | 2 to 3 g/L |
Lime: | Saturated |
Before air jet cleaning system was introduced, the cleaning work by hand had been required at least once a week. Continuous air jet cleaning using the submersion holder with jet cleaning system, has reduced the maintenance frequency to once a month or two months.
To ensure stable measurement, the pH sensor uses a Teflon liquid junction, where the KCl outflow is higher than that of ceramic junction.
Industrien
-
Mining & Metal
Mining operations produces valuable minerals or geological materials from the Earth. Economical recovery often requires high throughput and high availability of the process with low operation costs, and stringent safety and environmental regulations.
Zugehörige Produkte & Lösungen
-
Digitaler SENCOM™ SMART-Adapter, SA11
Wiederverwendbarer SMART-Adapter, bei dem nur der Analogsensor am Ende der Lebensdauer entsorgt werden muss. Mit der Plattform SENCOM 4.0 reduziert Yokogawa Kosten und Abfälle und trägt damit zu seinem langfristigen Unternehmensziel einer nachhaltigen Zukunft für alle bei.
-
Mehrkanal-4-Leiter-Analysator FLXA402
Die Analysatoren der FLEXA™-Serie sind modular gestaltete Analysegeräte für kontinuierliche Online-Messungen in industriellen Anlagen. Sie ermöglichen Messungen mit einem oder mehreren Sensoren.
-
pH/ORP-Universalsensor der Serie FU20 und FU24
Die Universalsensoren FU20 und FU24 für pH und ORP (Redox) zeigen, wie Yokogawa das Motto „einfach ist am besten“ auf Sensortechnologie anwendet.
-
pH- und ORP-Analysatoren
Sensoren und Analysatoren für pH und ORP (Redox) werden zur kontinuierlichen Überwachung von pH- und ORP-Werten im Prozess eingesetzt, z.B. um die Wasser- und Produktqualität sicherzustellen oder um Abflüsse, Batch-Neutralisierung, Zellstoffbestand, Gaswäscher, Kühltürme, chemische Aufbereitung, Wasser- und Abwasserbehandlung und viele andere Anwendungen zu überwachen.
-
pH- und Redoxsensoren
pH-Elektroden und -Sensoren sind die detektierenden Elemente bei der Messung des pH-Werts. Die verschiedenen Installationsoptionen schließen u. a. Wechsel-, Durchfluss- und Eintaucharmaturen sowie den direkten Einbau ein. Die richtige Auswahl von pH-Elektroden und Sensoren ist für optimale Messergebnisse von entscheidender Bedeutung.