pH in Diazo Coupler

Introduction

Diazonium Coupling (Diazo Coupling, Azo Coupling):

Due to their positive charge, diazonium cations, which are generated by treatment of aromatic amines with nitrous acid and a stronger mineral acid, may participate in an electrophilic aromatic substitution as an electrophile. The electrophilic reaction center is the terminal nitrogen of the - N=N group. As a result, two aromatic compounds are coupled by a -N=Ngroup. This is known as the azo group (diazo group).

Diazonium Coupling (Diazo Coupling, Azo Coupling)

graph

The corresponding reaction is called diazonium coupling (diazo coupling, azo coupling). However, the electrophilicity of diazonium ions is only relatively weak, as their positive charge is delocalized.an2 The unsubstituted benzenediazonium cation may react only with strongly activated aromatic compounds, such as phenolates and amines.

Azo coupling is the most widely used industrial reaction in the production of dyes, lakes and pigments. Aromatic diazonium ions acts as electrophiles in coupling reactions with activated aromatics such as anilines or phenols.

The substitution normally occurs at the para position, except when this position is already occupied, in which case ortho position is favoured. The pH of solution is quite important; it must be mildly acidic or neutral, since no reaction takes place if the pH is too low.

 

Application Information

Typical process details:

  • Chemical Composition - Coupler + Diazo Coupler – 48 % caustic + Nepthol + Water Diazo -36% HCL + Diecloro Anelene + Water Operating Temperature – 55°C
  • Operating Pressure – 4 kg/cm2

Summary

The process is indeed quite aggressive so Glass is best material.

Sensor Selection:

Sensor Option #1: SC21C-AGC55 would be best, if it is possible to pressurize the electrolyte to 5 bar (72PSI).

Features for type SC21C-AGC55

  • Heavy duty pH sensitive glass.
  • Flowing reference system for pollution resistance, and highly stable reference potential.
  • Use in combination with the presurisable electrolyte reservoir to obtain a positive flow towards the process (K1500YA)

Sensor Option #2: (-FTS or -FTS) →(-FTS or -MTS) is possible if the cation (salt) content is stable during the pH control step.

Features

The FU20-*-FTS and FU20-*-MTS are a differential pH sensors. This means that the reference is not a (liquid) junction but a glass sensor which does not respond to pH changes (within the applicable range of the sensor). Therefore the sensor is truly maintenance free and the output voltage of the sensor depends only on the salt concentration of the process.

The sensor responds to pH changes rather than analyses the accurate pH value. In that sense it is best to describe the sensor as pH control sensor rather than pH measuring sensor. A pH sensor measures the voltage that the pH membrane measures as function of the pH value of the process sample. This voltage is then compared with the mV output of a reference cell that is independent on the pH value of the sensor.

In most pH control applications the salt concentration is rather constant, so the output of the FU20 differential sensor is only dependent on the pH of the process. A rule of thumb is that a change in salt concentration of +/- 25% has an effect of less than 0.1pH on the pH reading.

 

Analyzer/ Transmitter Selection:

Option #1: 4 wire pH Analyzer
4 wire pH Analyzer

Features

  • Easy touchscreen operation
  • Multi sensor input available

Option #2: 2 wire pH transmitter
2 wire pH transmitter

Features

  • Redundantsystem on dual sensor measurement
  • Easy touch screen operation on 2-wire type analyzer

Tangible benefit:

More reliable and accurate analysis of pH which helps to improve end product quality.

 

Průmysly

  • Petrochemický

    Whether you produce petrochemicals, inorganics or intermediates, chemical companies are under cost and margin pressures to deliver products in a timely and efficient manner while maintaining safe and compliant operations. Additionally, chemical companies need to adjust to fluctuating feedstock and energy prices and to provide the most profitable product mix to the market.

    Yokogawa has been serving the automation needs of the bulk chemical market globally and is the recognized leader in this market. With products, solutions, and industry expertise, Yokogawa understands your market and production needs and will work with you to provide a reliable, and cost effective solution through the lifecycle of your plant.

    Viz více

Související produkty a řešení

  • 2-Wire Transmitter/Analyzer FLXA202

    The FLEXA™ series analyzers are used for continuous on-line measurements in industrial installations. With an option for single or dual sensor measurement, they are the most flexible two-wire analyzer available.

    Viz více
  • 2-Wire Transmitter/Analyzer FLXA21

    The FLEXA™ series analyzers are used for continuous on-line measurements in industrial installations. With an option for single or dual sensor measurement, they are the most flexible two-wire analyzer available.

    Viz více
  • pH and ORP Analyzers

    pH and ORP meters, analyzers and transmitters are used for continuous process monitoring of pH and ORP to ensure water/product quality, monitor effluent discharge, batch neutralization, pulp stock, scrubbers, cooling towers, chemical, water/wastewater treatment and many other applications.

    Viz více