You can use the Windows telnet command.
- Click Start > All programs > Accessories > Command Prompt.
- At the command prompt, type "telnet. "
- Given a DX IP address of "10.1.32.130," type the following (the port number is 34260).
Microsoft Telnet>open 10.1.32.130 34260 - When E1 402 is displayed, type "admin. " If E0 is displayed, logon was successful.
- To log off, type "cc0. "
For details on logging on, see Appendix 2, "Logging On " in the communication interface user's manual (IM04L41B01-17E)