Measurement of O2 Concentration in Hot Blast Stoves

Загрузить (690 KB)

Introduction

Hot Blast Stove Process
Hot Blast Stove Process

Measurement of O2 Concentration in Hot Blast Stoves Essential to Improving Combustion Efficiency

In a hot blast stove, the by-product gas produced in a coke oven is burned to preheat the air blast for the blast furnace. To improve the combustion efficiency and conserve energy in a hot blast stove, it is essential to be able to control combustion by measuring and adjusting the oxygen concentration in the exhaust gases.
The ZR22G/ZR802G Direct In-Situ Zirconia Oxygen Analyzer is ideally suited for combustion control in hot blast stoves. It utilizes a long-life sensor.

Expected Benefits

  • Improves combustion efficiency in hot blast stoves
  • Ensures stable, continuous oxygen measurement
  • Reduces operating costs
  • Minimizes the need for equipment replacement

Process Overview

The temperature of the hot blast used in blast furnaces has been increasing every year and currently stands at around 1300°C. Under such circumstances efficient operation is achieved by such measures as increasing the calorie value of fuel gas, replacing the hot blast furnace more frequently, and recovering waste heat from gas. To further improve combustion efficiency and save energy, measurement of the oxygen concentration in exhaust gases is required.

Solution Details

Field Data

Process Conditions

Measurement: 20 to 350 ℃
Pressure point: Duct
Temperature: 3.5 to 10 kPa
Dust: 50 mg/Nm3
Fuel: Gas

Measurement System

Detector: ZR22G-015-S-Q-E-☐-☐-E-A /CV/Z
Z: Glove box option
Converter: ZR802G-☐-☐-N-N /☐
Flow setting unit: ZA8F-☐*C
Pressure regulator: G7013XF or G7014XF
Case for calibration gas cylinder: E7044KF

Note: the calibration gas cylinder must be purchased locally

Utilities

Rated voltage: 100 to 240 V AC
Rated frequency: 50/60 Hz
Power consumption: 330 VA (Max. 800 VA)
Instrument air (reference gas) pressure: 300 to 700 kPa

Notes

  • The detector is installed in a glove box to reduce the sample gas pressure.
  • When more than three detectors are installed, it is recommended that the AV550G Averaging Converter be used instead of the ZR802G converter. The AV550G accepts signals from up to eight detectors.

Solution Details

Отрасли

  • Металлургия

    В отрасли металлургии крайне важно повышать качество не только продукции, но и технологий производства и эксплуатации, а также решать вопросы экологии и энергоэффективности. Компания Yokogawa помогает заказчикам в создании идеального предприятия, а также развивается вместе с ними ради совместного роста.

    Узнать больше

Related Products & Solutions

  • Циркониевый анализатор кислорода ZR22G/ZR802G

    Данная система анализа концентрации кислорода и влажности при высоких температурах включает детектор ZR22G, оснащенный долговечным и высоконадёжным циркониевым датчиком, и преобразователь ZR802G, имеющий функции цифровой связи и регистрации данных.
    Детектор ZR22G и преобразователь ZR802G позволяют выполнять измерения непосредственно и непрерывно без использования пробоотборного устройства. Они отличаются простотой технического обслуживания и позволяют снижать эксплуатационные затраты благодаря возможности самодиагностики износа датчика (без использования калибровочного газа) и замены узла нагревателя на месте.

    Узнать больше

Наверх