Introduction
Cell migration is fundamental in various physiological processes including ontogeny, and is involved in variety of diseases such as osteoporosis, arthritis, congenital brain and heart abnormalities and cancer metastasis.
Cell migration is also important for the regeneration of damaged tissues.
To assess the capability of cells to migrate, the scratch assay is one of the most widely used assay because of its simplicity and inexpensiveness. In this application note, we provide an example of scratch assay by using CQ1. We carried out time lapse live cell imaging to examine the temporal change of the distribution and the number of cells in scratch assay.
Figure 1. Time lapse images of monolayer cultures of HeLa cells transfected with Fucci.
(A and B) Cultures without (A) and with (B) mitomycin C (MMC) treatment.
Upper and lower panels shows large field images and higher magnification images showing recognized cells in the white frame in the upper panels.
Red and green labels indicate cells in G1 and S/G2/M phase, respectively.
Figure 2. Temporal change of the number of cells in the cell-free gap
Number of cells in the cultures shown in figure 1 is plotted against time. Red and green bars represent cells in G1 and in S/G2/M phase, respectively.
Figure 3. Scratch assay
A Cell-free gap are created by making a scratch on confluent monolayer cell culture. Then the invasion of migrating and/or proliferating cells into the gap is assessed.
Experimental procedures
• HeLa cells transfected with Fucci were seeded in a 24-well plate (Greiner#662160) and incubated for a day.
• A scratch was created with a pipette tip on the confluent monolayer cell culture.
• MMC was applied in the well for an hour to stop the cell division cycle then washed out.
• Time lapse images were acquired by CQ1 for three days.
• Image acquisition settings: 10x objective lens, 30% laser power, 500 ms exposure and 1 hr interval.
Results and Discussion
We performed scratch assay by using CQ1 and were able to capture the process of infiltration of the cells into the cell-free gap with time.
In the well without MMC treatment, the cell cycle proceeded and the number of cells both in G1 phase and cells in S/G2/M phase increased in the cell-free gap with time, suggesting that the gap was filled with migrating and proliferating cells.
The number of cells in the gap also increased with time in the well treated with MMC.
However, most of the cells in the MMC treated well were in S/G2/M phase indicating that the cell cycle was arrested.
This result suggests that the gap was filled mostly with migrating cells.
The present experiment demonstrates that CQ1 is an excellent tool for the quantitative analysis of cell migration and proliferation.
*FUCCI
Fluorescent Ubiquitination-based Cell Cycle Indicator.
Cells transfected with this probe emit red fluorescence in G1, and green fluorescence in S/G2/M phase, respectively.
*Mitomycin C (MMC)
MMC damages DNA and prevents DNA replication by making DNA crosslinks and producing free radicals when metabolized.
Our Social Medias
We post our information to the following SNSs. Please follow us.
Follow us | Share our application | |
@Yokogawa_LS | Share on Twitter | |
Yokogawa Life Science | Share on Facebook | |
Yokogawa Life Science | Share on LinkedIn |
Yokogawa's Official Social Media Account List
Related Products & Solutions
-
Benchtop CQ1 Confocal System
The CellVoyager CQ1 provides the highest quality confocal images and extended live-cell imaging in a space-saving benchtop design.
-
CellPathfinder
CellPathfinder is designed for our HCA systems, CQ1 and the CellVoyager series. From beginners to experts, the analysis software lets you quantify subtle physiological changes and even label-free samples with various graph options.
-
CV8000 High-Throughput System
CellVoyager CV8000 is the most advanced high-content screening system. The improved built-in incubator lets you analyze extended live cell responses. With its expandability, 4 cameras, 5 lasers and an optional built-in pipettor, the system permits increasingly complex assay development and high-content screening.
-
High Content Analysis CellVoyager
Our high-content analysis (HCA) systems utilize powerful software to address a wide range of research applications from basic science to complex compound screening.
-
Life Science
Yokogawa’s high content analysis systems and dual spinning disk confocal technologies provide high-speed and high-resolution live cell imaging, enabling leading-edge research around the world.