EJA120E

The EJA120E is a traditional-mount draft range pressure transmitter. Available with HART 5/7, 1 to 5 VDC HART 7 (Low Power), FOUNDATION Fieldbus, PROFIBUS PA, or BRAIN communication.

Details

What Are the Benefits of Draft Range Differential Pressure Transmitters?

Reduce maintenance cost by 33%.

Quicker = Less Downtime

Improved long-term stability extends calibration intervals. Spend your time where it is needed.

Multiple Communication Options

Save time. Save money

FieldMate PC based communication platform allows management of your entire instrument inventory.

FieldMate HHC allows you to take that information into the field.

LPS can update 9 parameters in the field without the use of an HHC.

Simple Troubleshooting

Save time. Save money

Local intuitive display with simple error messaging.

NE107 compliant alarms in FieldMate make troubleshooting easy.

 

Standard Protocols

No training required.

Yokogawa transmitters support all industry standard field device protocols. Interoperability and interchangeability can be ensured. Use the same tools and work procedures as before.

No Learning Curve = Smooth Change Over

 

Standard Industry Connections

Process connections designed to meet IEC61518 ensure you will not meet proprietary manifolds or accessories that limit your design choices.

How to Reduce Total Cost of Ownership?

Plants run better with Yokogawa pressure transmitters. At its heart, Yokogawa's Differential Pressure Transmitter with DPharp digital sensor offers the performance and device intelligence needed to get greater insight into your process.

 

Digital Performance

Poor Performance = Lost Money

Installed performance 2x better using all digital DPharp pressure sensor.

Yokogawa’s digital sensor provides superior performance and stability compared to analog sensors.

Dynamic Compensation

Compensates for process changes to improve accuracy.

 



 

 

 

Standard Diagnostics

Good Diagnostics = Less Surprises

Reduce unscheduled maintenance by 60%

Over 40 diagnostics to ensure everything is OK. Active Sensor Technology monitors the DPharp sensor while the Patented Back-check Technology is reverse checking all calculations in real-time.

How Are Draft Range Differential Pressure Transmitters Built?

Ruggedness = Reliability

Yokogawa's DPharp active sensor, patented back check diagnostics, and rugged construction allow users to run their plants safer and with less downtime. Yokogawa pressure transmitters help plants run longer. The transmitters are designed to outlive your plant and can reduce failures in the field by 200%.

 

Over-pressure Protection

Reduce failures and calibrations.

Yokogawa DPharp pressure transmitters have an integral over-pressure mechanism to protect your transmitters from process surges or improperly sequenced manifolds.

Proven Technology

Less Downtime = Making Product

 

Over 6 million DPharp transmitters are installed worldwide.

 

Reliability Guaranteed

Reliability verified independently by third party industry experts.

 

Inherently Safe

Inherently Safe = Reliability

Save up to 10% on CAPEX spending.

All Yokogawa pressure transmitters are certified to meet IEC61508 for single use in SIL 2 applications or dual use in SIL 3 applications as a standard. No special option needed! To Yokogawa, safety should never be an option.

 

Active Sensor Technology

Unlike other sensor technologies, the active DPharp sensor constantly produces a signal even if there is no change in the process. This signal is continually monitored by the CPU.

Patented Self-check System

All calculations are checked by reverse calculation in real-time ensuring the highest reliability.

EJA120E Overview

Measurement Types
Primary Variable Differential Pressure (Draft Range)
Reference Accuracy
Primary Variable ±0.2% of Span
Response Time
Primary Variable 150 msec
Rangeability
Primary Variable 10:1

WPC005.a

EJA120E Capsule

MSC010.a

Graphics are not to scale.

Valves

Manifolds

For Differential pressure transmitters, Yokogawa offers a complete line of 61518 IEC compliant 3-valve and 5-valve manifolds. Available in T-Style, H-Style, Wafer-Style, and Bottom Process Connection Style, they can be ASME B31.1 (Power) Compliant, ISA 15848 Compliant, or TA-Luft Compliant.

Learn More

 

Resources

Overview:
  • CENTUM VP Batch package improves productivity.
  • Reduction of operator workload and safe operation.
Industries:
Overview:

Yokogawa DPharp EJA/EJX Pressure transmitters do not need frequent re-zeroing due to superior long term stability, it contributes to reduce maintenance time.

Industries:
Overview:

Download this eBook and learn:

  • The basic physics of pressure
  • Different types of pressure sensors
  • Features of pressure transmitters
  • Pressure transmitters communications standards
  • Key characteristics of pressure
  • Common types of diaphragm seals
FieldGuide
688 KB
FieldGuide
756 KB
Overview:

Extend your differential pressure transmitter's range with affordable isolation solutions, shielding it from extreme process temperatures and corrosive fluids.

FieldGuide
493 KB
FieldGuide
632 KB
FieldGuide
1.0 MB
Overview:

Yokogawa's cost-effective and user-friendly, differential pressure volumetric flow measurement with accuracy ranging from 0.5% to 1.5%, ensures efficient process control at a competitive price compared to other flow technologies.

FieldGuide
659 KB
Overview:

Discover the safety features built-in to the Yokogawa digital pressure sensors (DPharp).

FieldGuide
813 KB
FieldGuide
708 KB
FieldGuide
608 KB
FieldGuide
743 KB
FieldGuide
658 KB
FieldGuide
717 KB

Downloads

2D/3D Configurator

Looking for more information on our people, technology and solutions?

Contact Us

Top