In the case of conditioners, time constant reflects the response speed. In terms of a transfer function, it is expressed as OUT=INΩ(1-e EXP(-t/T)).
OUT: output, IN: input, e: natural log, T: time constant, t: elapsed time
When the elapsed time reaches the time constant, the e exponent becomes -1, and OUT becomes 63% of IN. When more time elapses, the exponent approaches -infinity, and OUT = IN.
Related Products & Solutions
-
JUXTA VJ Series Computing Units
The VJ Series are compact, but the line-up includes versatile I/O specifications, wide-range of power supply, isolated two outputs and field configurable models.
-
JUXTA VJ Series Limit Alarms
The VJ series limit alarms are compact, plug-in type alarm setting devices with easy-to-use functions. Four models are available: the VJAK for 2-wire system transmitters; the VJHK with DC voltage/DC current inputs; the VJRK with RTD inputs; the VJTK with thermocouple inputs; and the VJUK with universal inputs.
-
JUXTA VJ Series Signal Conditioners
Compact size, plug-in style and microprocessor based high performance capabilities (Multi-function types) makes the VJ Series Signal Conditioners an excellent choice for almost every application. Analog output, Hi-Low alarm relay outputs or RS-485 MODBUS communication is available as optional second output.