The input impedance of typical current input type instruments is 250 MΩ. By contrast, the allowable load impedance for current output is 750 kΩ or more, therefore the maximum number of units that can be connected is 3.
Related Products & Solutions
-
JUXTA VJ Series Computing Units
The VJ Series are compact, but the line-up includes versatile I/O specifications, wide-range of power supply, isolated two outputs and field configurable models.
-
JUXTA VJ Series Limit Alarms
The VJ series limit alarms are compact, plug-in type alarm setting devices with easy-to-use functions. Four models are available: the VJAK for 2-wire system transmitters; the VJHK with DC voltage/DC current inputs; the VJRK with RTD inputs; the VJTK with thermocouple inputs; and the VJUK with universal inputs.
-
JUXTA VJ Series Signal Conditioners
Compact size, plug-in style and microprocessor based high performance capabilities (Multi-function types) makes the VJ Series Signal Conditioners an excellent choice for almost every application. Analog output, Hi-Low alarm relay outputs or RS-485 MODBUS communication is available as optional second output.