Measuring Water Quality at Water Purification Plants

Introduction

Improving potable water quality, safety, and sustainability of the drinking water supply are our mission for the future. To achieve them, measuring water quality accurately and contentiously are very important. The measurement of turbidity in potable water facility and distribution line is a vital component of ensuring safe and clean drinking water.
FLXA402T/TB820D right angle scattered light turbidity analyzer is used to control and monitoring drinking water quality. WHO says in "Guidelines for drinking-water quality" that "to ensure effectiveness of disinfection, turbidity should be no more than 1NTU and preferably much lower. Large, well-run municipal supplies should be able to achieve less than 0.5 NTU before disinfection at all times and should be able to average 0.2 NTU or less." FLXA402T/TB820D can measure from 0-2 NTU to 0-500 NTU with excellent accuracy and have been contributed to healthy life. To achieve continuous measurement, FLXA402T/TB820D equipped useful functions, for example diagnostics, automatic cleaning and automatic zero calibration. These functions help to improve water quality control.

 

Expected Benefits

  • Measures low turbidity levels both continuously and accurately
  • Reduces operating cost
  • Eliminates the need for manual cleaning
  • Keeps the initial cost of equipment replacement to a minimum
  • Multiple sensor input to a converter is available (Turbidity, Residual chlorine, pH and Conductivity)

Process
Process

 

Process Overview

The potable tap water distributed to individual households is originally produced from raw water taken from rivers or underground springs. At water purification plants, chemicals are injected into the raw water to produce flocs that serve to absorb hazardous substances in the raw water and allow them to be deposited and filtered out. Chlorine is then added as a disinfectant to the treated water. A variety of water quality measuring instruments, including turbidity analyzers, residual chlorine analyzers, and pH meters, are used in water purification plants. This application note focuses on turbidity analyzers, which are used to verify that filtration systems are operating in excellent condition. The FLXA402T/TB820D turbidity analyzer continuously measures post-filtration turbidity in order to achieve the required turbidity control value of 0.1 mg/L.

 

Solution Details

Measurement system

Right angle scattered light turbidimeter
Model: FLXA402T-A-B-□□-TB-□□-N□-WR-N-□-N-NN-NN
TB820D-□□-□□-□□-NN-CT-NN/D□
Main components: Turbidity detector, converter, pressurized head tank
Primary product specifications:
Measuring range: 0-0.2 to 0-500 NTU
0-0.2 to 0-700 FNU/NTU
Output signal: 4-20 mA DC, Modbus TP/IP, Modbus RTU (RS-485)
Installation location: indoors
Zero-turbidity filters (to be purchased separately)
Filter assembly 1 micron: P/N K9008ZD
Filter assembly 0.2 micron: P/N K9726EH

 

Utilities for FLXA402T/TB820D

Power supply: 100-240 V AC, 50/60 Hz Power
Power consumption: Approximately 120 VA

Note on installation

This turbidity analyzer uses a pressurized head tank to eliminate air bubbles, which are a major error factor in the measurement of low turbidity levels.

Utilities for FLXA402T/TB820D

Utilities for FLXA402T/TB820D

Industries

  • Drinking Water Treatment

    The goal of drinking water treatment is to produce clean, safe, and potable water that meets regulatory standards and is suitable for drinking and other domestic uses.

    See More
  • Water & Wastewater

    All water, regardless of its source, has value. However, with water resources being finite, a focus on "One Water" is necessary to maximize every drop within the water system, ensuring a stable supply of clean and safe water.  As we consider current and future needs, planning and implementation are critical for long-term resilience and reliability, meeting both community and ecosystem demands. Yokogawa believes water is a human right for all. Thus, contributing to a sustainable water cycle is one of our Sustainable Development Goals (SDGs).

    See More

Related Products & Solutions

×

Have Questions?

Contact a Yokogawa Expert to learn how we can help you solve your challenges.


Top