Explosion-Protected Model Infrared Gas Analyzer IR810S

NDIR Anayzer for Hazardouse Area CEMS and Combustion Control

IECEx/ATEX ZONE1

In recent years, environmental measurement has become increasingly important from the perspective of SDGs and carbon neutrality, and measurement accuracy standards are becoming more stringent every year.
The IR810S complies IECEx/ATEX ZONE1 and is the most suitable analyzer for hazardous area CEMS (Continuous Emission Monitoring System) thanks to uniqe measurement mechanism, and can meet the environmental regulations of various countries. It can also be used to manage process combustion in hazardous area for efficient control.
Yokogawa has been selling gas analyzers for environmental measurement since 1971, and continues to develop and improve them based on its many years of experience and achievements. The highly reliable IR800 series contribute to environmentally conscious factories by making their operations easier to measure.

The IR800 series infrared gas analyzer can measure concentrations O2 and up to 4 other components (NO, SO2, CO, CO2, CH4) in a sample gas using a non-dispersive infrared (NDIR) method. And as environmental regulations are becoming stricter, we have achieved stable measurement with less drift.

Our Active Zero-Drift Cancellation Mechanism achieves stable measurement of low concentrations, which are traditionally difficult to measure. It also includes Engineering/ASI functions—no need to add them separately.


About OpreX

OpreX is the comprehensive brand for Yokogawa’s industrial automation (IA) and control business and stands for excellence in the related technology and solutions. It consists of categories and families under each category. This product belongs to the OpreX Analyzers family that is aligned under the OpreX Measurement category.

Details

Solve Gas Measurement Challenges

An Active Zero-drift Cancellation Mechanism is Key to Stable Long-Term Measurement

By alternately measuring the sample gas and a reference gas, the zero point is constantly corrected and the measurement drift caused by cell contamination can be canceled to maintain accurate measurements.

Drift cancellation mechanism is key to long-term stability measurement

Intuitive Operation with a Full-Color Touch Panel

An HMI that is easier to read and operate in both bright and dim surroundings.

Intuitive Operation with a Full-Color Touch Panel

 

Easy Maintenance

One-touch Calibration
You can open the calibration menu directly from the full color touch panel display, which also clearly shows the measured components during calibration.

Automatic Blowback
Digital contacts can be opened and closed for blowback, and the blowback period and other parameters can be changed from the screen without engineering. Remote operation is also available to ensure that optimal operations are always performed according to the customer's conditions.

Automatic Validation
Validation can be performed using calibration gases. With available System or Analyzer validation,  measured values are recorded to help you determine the optimal maintenance window.

 

Type of Protection

Pressurized Enclosure and Flameproof Enclosure

  • ATEX: II 2 G Ex db pxb IIB + H2 T4 Gb
  • IECEx: Ex db pxb IIB + H2 T4 Gb

What is CEMS?

CEMS (Continuous Emission Monitoring System) is a measurement system for monitoring exhaust gas from factories and other sources. Implementing CEMS with the IR800 series meets these needs:

  • Demand for CEMS due to increased awareness of environmental problems and stricter laws and regulations.
  • Minimal installation and maintenance costs.
  • Detailed operations to minimize the risk of downtime and anomalies, and to improve maintenance and operational efficiency.
  • Demands to install CEMS in the hazarous area to reduce cost and response time.
What is CEMS?

 

Wide Range of Applications

Our sampling technology and systems are optimized for a wide range of applications, from environmental solutions to research on next-generation energy.

  • All industries: CEMS, combustion management of various boilers
  • Petroleum, petrochemicals and chemicals: Gas measurements in furnaces and other facilities
  • Steel: Measurement of lime kiln, CDQ circulating gas, blast furnace top gas and converter recovery gas
  • Ceramics: Gas measurement in parts of cement kilns
  • Others: Gas measurements at biogas plants, in fuel cells, and plant research facilities

 

Example of Measuring in an Iron and Steel Plant

Example of Measuring in an Iron and Steel Plant

 

Example of Measuring in a Cement Kiln

Example of Measuring in a Cement Kiln

 

Measurable Gas Components and Measuring Ranges

Component Range
NO 0-50 ppm to 0-5000 ppm (Optional range : 0-50 ppm to 0-199 ppm)
SO2 0-50 ppm to 0-5000 ppm, 0-2 vol% to 0-10 vol%
(Optional range : 0-50 ppm to 0-199 ppm)
CO 0-50 ppm to 0-5000 ppm, 0-2 vol% to 0-100 vol%
(Optional range : 0-50 ppm to  0-199 ppm, 0-51 vol% to 0-100 vol%)
CO2 0-1000 ppm to 100 vol%
(Optional range : 0-1000 ppm to 0-4999 ppm, 0-26 vol% to 0-100 vol%)
CH4 0-2 vol% to 0-100 vol% (Optional range : 0-51 vol% to 0-100 vol%)
O2 0-5 vol% to 0-100 vol% * 0-25 vol% to 0-100 vol% for hydrogen background