Introduction
Pigment producer manufacture produces pigments to supply to paints, plastics, inks, construction, textile and cosmetics manufacturers etc. The pigments come under wide range - general purpose grades, high performance, and specialist hard-to make colours and effect pigments.
Pigments and chemicals form an intrinsic part of many industries. They serve as raw materials in the manufacturing of Plastic, Rubber, Paint, Paper, Textile, Tiles, Detergent Powder and Soaps, Inks, and Photo Films etc.
Pigments come in a wide variety of colours and some are water-soluble. For these reasons, many of these compounds have been produced, isolated, and characterized.
Among the most important variables affecting processes, pH and temperature are environmental conditions with a strong effect on the pigments. Thus, it is very important to control them in industrial bioprocesses.
Balancing the pH
The degree of acidity or alkalinity of a solution, known as pH, is measured from 0 to 14. Acid solutions measure 0 to 7. Alkaline (smells like ammonia) solutions measure 7 to 14. Pure distilled water measures 7. There are instruments to measure pH, or you can rely on sense of smell. The binder should have a slight ammonia odor. We are shooting for a pH range of 8.0 to 8.8. The acrylic polymer used to make paint becomes unstable at a pH below 7.5. Adding a dispersion may lower the pH below the optimum range. Also, adding thickeners will typically lower the pH. If polymer binder starts looking and acting like cottage cheese then chances are pH is too low. Try raising the pH to salvage the batch. Do this with the drop-wise addition of Ammonium Hydroxide (NH4OH) while mixing. If the mixture does not respond to the pH correction, allow it to dry out for disposal.
Controlling Viscosity and Rheology
Thickness or viscosity is generally well understood. Rheology usually bears a bit of explanation. Long rheology refers to a stringy, resinous, quality, like that of honey. Industrial enamels and automotive paints often exemplify these qualities. Short rheology refers to a smoother, less "ropy" paint formulation, typical of what acrylics and oil paints are known to be. To create different rheologies, you can choose the appropriate gel or medium to combine with the dispersion. These are pH sensitive polymers that swell up when the paint's pH is 8.0 - 9.5 (It is critical to keep the paint in this range.)
Ammonia is used to maintain the pH in the acceptable range. Ideally, this is determined with a pH meter, and is characterized by a slight ammonia odor. You will feel the mixture get thicker as you proceed. (If you are getting chunks it may be a result of adding the Thickeners too quickly or insufficient mixing.) Blend until the mixture is smooth and of the desired thickness.
Typical Process details as an example:
Typical problems
- What is the concentration of these chemicals?
- Customer may say it is difficult to give concentration of these chemicals.
- What is the process pressure?
- Process pressure: atmospheric pressure
- Calibration frequency
- Once in a day. Customer has observed drift of @1 PH every day i.e. why calibration is done daily.
- Scaling?
- Yes scaling shall be observed on electrode
- CIP/SIP
- No.
- Typical sensor life @1 1/2 months to max. 2 months
- Process temp.
- varies from -5 to +105 deg C, typical batch process temp. will be 95 degC (changes from manufacturer to manufacturer)
Remedies
- Use sensor with most chemically resistant Ryton body.
Product Recommendation
Measurement System
Process Liquid Analyzer:
- 2-wire FLEXA pH/ORP Analyzer
Features
- Dual sensor measurement on 2-wire type analyzer
- Indication of sensor wellness
- 4-wire FLXA402 pH/ORP Analyzer
Features
- Connectable to up to five sensor
- Easily viewable color LCD
- Touch screen operation
Sensor Selection:
pH immersion fitting like PH8HS / equivalent with PH8EFP sensor.
Features
- With the body made of Ryton, a strong engineering plastic, which is comparable to Teflon in terms of corrosion resistance and heat resistance, it allows for a wide range of applications.
- The integrated-sensor design simplifies calibration with standard solutions and maintenance.
- The pH glass electrode of a pH sensor, the platinum or gold electrode of a ORP sensor and junction can be individually replaced.
Tangible benefit
More reliable and accurate analysis of pH which helps to improve end product quality and total operation cost is less.
Note: For additional information on this application contact the local Yokogawa Process Liquid Analyzer Department
Industries
-
Chimie
Les usines chimiques s'appuient sur des processus de production continus et discontinus, chacun posant des exigences différentes en matière de système de contrôle. Un processus continu nécessite un système de contrôle robuste et stable qui ne tombera pas en panne et n'entraînera pas l'arrêt d'une ligne de production, alors que dans le cas d'un processus discontinu, l'accent est mis sur un système de contrôle qui permet une grande flexibilité dans les ajustements des formules, des procédures, etc. Les deux types de systèmes doivent être gérés en fonction de l'historique de la qualité du produit et être en mesure d'exécuter des opérations non routinières. Avec son large portefeuille de produits, ses ingénieurs systèmes expérimentés et son réseau mondial de vente et de service, Yokogawa a une solution pour chaque processus d'usine.
-
Chimie de Base
Yokogawa sert le marché des produits chimiques en vrac dans le monde entier et est reconnu comme le leader de ce marché. Avec ses produits, ses solutions et son expertise industrielle, Yokogawa comprend votre marché et vos besoins de production et travaillera avec vous pour vous fournir une solution fiable et rentable tout au long du cycle de vie de votre usine.
Les produits et solutions liés
-
2-Wire Transmitter/Analyzer FLXA202
The FLEXA™ series analyzers are used for continuous on-line measurements in industrial installations. With an option for single or dual sensor measurement, they are the most flexible two-wire analyzer available.
-
2-Wire Transmitter/Analyzer FLXA21
The FLEXA™ series analyzers are used for continuous on-line measurements in industrial installations. With an option for single or dual sensor measurement, they are the most flexible two-wire analyzer available.
-
Multi Channel 4-Wire Analyzer FLXA402
The FLEXA™ series analyzers are modular-designed analyzers used for continuous online measurements in industrial installations. They offer single or multi-sensor measurement.
-
pH/ORP Sensors PH8EFP, PH8ERP, OR8EFG, OR8ERG
Yokogawa's pH and ORP analyzers are highly reliable. They feature advanced functions and are useful for a wide variety of applications including water quality management in a broad range of production processes and in medium-sized wastewater treatment plants, or as general pH and ORP control systems.
-
Conductivity Analyzers
Conductivity meters, analyzers and transmitters are used for continuous process measurement and monitoring of conductivity, resistivity, WIFI, demineralizer water, RO water, percent concentration, boiler blowdown and TDS.
-
Conductivity Sensors
Conductivity sensors and electrodes are used to measure process conductivity, resistivity, WIFI, demineralizer water, RO water, percent concentration, boiler blowdown and TDS. Various installation options including retractable, flow thru, immersion, and direct insertion. Proper electrode/sensor selection is critical for optimal measurement results.
-
Liquid Analyzers
Liquid analyzers are used for monitoring process chemistry including water quality, providing process optimization and control.
-
pH and ORP Analyzers
pH and ORP meters, analyzers and transmitters are used for continuous process monitoring of pH and ORP to ensure water/product quality, monitor effluent discharge, batch neutralization, pulp stock, scrubbers, cooling towers, chemical, water/wastewater treatment and many other applications.
-
pH and ORP Sensors
pH electrodes and sensors are the sensing portions of a pH measurement. Various installation options including retractable, flow thru, immersion, and direct insertion. Proper pH electrode/sensor selection is critical for optimal measurement results.