Introduction
Improving potable water quality, safety, and sustainability of the drinking water supply are our mission for the future. To achieve them, measuring water quality accurately and contentiously are very important. The measurement of turbidity in potable water facility and distribution line is a vital component of ensuring safe and clean drinking water.
FLXA402T/TB820D right angle scattered light turbidity analyzer is used to control and monitoring drinking water quality. WHO says in "Guidelines for drinking-water quality" that "to ensure effectiveness of disinfection, turbidity should be no more than 1NTU and preferably much lower. Large, well-run municipal supplies should be able to achieve less than 0.5 NTU before disinfection at all times and should be able to average 0.2 NTU or less." FLXA402T/TB820D can measure from 0-2 NTU to 0-500 NTU with excellent accuracy and have been contributed to healthy life. To achieve continuous measurement, FLXA402T/TB820D equipped useful functions, for example diagnostics, automatic cleaning and automatic zero calibration. These functions help to improve water quality control.
Expected Benefits
- Measures low turbidity levels both continuously and accurately
- Reduces operating cost
- Eliminates the need for manual cleaning
- Keeps the initial cost of equipment replacement to a minimum
- Multiple sensor input to a converter is available (Turbidity, Residual chlorine, pH and Conductivity)
Process
Process Overview
The potable tap water distributed to individual households is originally produced from raw water taken from rivers or underground springs. At water purification plants, chemicals are injected into the raw water to produce flocs that serve to absorb hazardous substances in the raw water and allow them to be deposited and filtered out. Chlorine is then added as a disinfectant to the treated water. A variety of water quality measuring instruments, including turbidity analyzers, residual chlorine analyzers, and pH meters, are used in water purification plants. This application note focuses on turbidity analyzers, which are used to verify that filtration systems are operating in excellent condition. The FLXA402T/TB820D turbidity analyzer continuously measures post-filtration turbidity in order to achieve the required turbidity control value of 0.1 mg/L.
Solution Details
Measurement system
Right angle scattered light turbidimeter | |
---|---|
Model: | FLXA402T-A-B-□□-TB-□□-N□-WR-N-□-N-NN-NN TB820D-□□-□□-□□-NN-CT-NN/D□ |
Main components: | Turbidity detector, converter, pressurized head tank |
Primary product specifications: | |
Measuring range: | 0-0.2 to 0-500 NTU 0-0.2 to 0-700 FNU/NTU |
Output signal: | 4-20 mA DC, Modbus TP/IP, Modbus RTU (RS-485) |
Installation location: | indoors |
Zero-turbidity filters (to be purchased separately) | |
Filter assembly 1 micron: | P/N K9008ZD |
Filter assembly 0.2 micron: | P/N K9726EH |
Utilities for FLXA402T/TB820D
Power supply: 100-240 V AC, 50/60 Hz Power
Power consumption: Approximately 120 VA
Note on installation
This turbidity analyzer uses a pressurized head tank to eliminate air bubbles, which are a major error factor in the measurement of low turbidity levels.
Industries
-
Eau et Traitement des Eaux Usées
Yokogawa fournit des solutions de contrôle pour une production d'eau durable en développant une technologie plus économe en énergie, en aidant à réduire l'empreinte carbone des opérations et en construisant des produits solides qui protègent l'environnement des contaminants. Grâce à notre technologie de pointe et à notre vaste savoir-faire en matière d'applications, nous travaillons avec vous pour fournir des solutions durables pour l'eau qui stimulent votre activité et ajoutent une grande valeur tout au long du cycle de vie de l'usine. Notre technologie et nos produits améliorent la performance des usines et garantissent qu'elles peuvent fonctionner de manière compétitive sur les marchés de l'eau actuels, tout en réduisant leurs coûts d'exploitation.
Yokogawa prend en charge une large gamme d'applications de contrôle de l'eau dans les marchés de l'eau municipale et industrielle.
-
Traitement des eaux
Yokogawa provides optimum solutions to improve the reliable operation of water treatment plants. These solutions include sophisticated technologies, unsurpassed product quality, and extensive application know-how throughout the lifecycle.
Les produits et solutions liés
-
Liquid Analyzer for Turbidity and Chlorine FLXA402T
The FLXA402T is the next-generation analyzer for the Turbidity detector and Chlorine sensor. The FLXA402T can connect up to two sensors of Turbidity, Chlorine, pH, and Conductivity, with digital communications availability.
-
Right Angle Scattered Light Turbidity Detector TB820D
The TB820D is a next-generation digital Turbidity analyzer and connects to FLXA402T. TB820D turbidity analyzer equipped LED as a light source, flat window structure cell, new diagnostic functions, ultrasonic cleaning, etc., and they will reduce your maintenance time dramatically.
-
Turbidity Analyzers
The TB820D is a next-generation digital Turbidity analyzer and connects to FLXA402T. TB820D turbidity analyzer equipped LED as a light source, flat window structure cell, new diagnostic functions, ultrasonic cleaning, etc., and they will reduce your maintenance time dramatically.