ADMAG AXG is a high-quality and highly reliable magnetic flowmeter, enhanced by Yokogawa's proprietary dual frequency excitation method.
Certified to SIL2 complied with functional safety standard IEC 61508, it can be used in safety instrumented systems up to SIL2 in simplex configuration and SIL3 in a redundant configuration. In addition, the AXG is certified in the Water industry with the NSF61 approval for drinking water.
Details
What Is the ADMAG Total Insight (TI) AXG®?
The ADMAG Total Insight (TI) AXG® is an electromagnetic flow meter featuring enhanced settings for customized setups, pre-defined trend views, and multiple configuration sets for fast changeover through micro SD card. The ADMAG TI AXG® comes standard with built-in verification, reducing total cost of ownership.
Some of the highlights of the ADMAG TI AXG® include:
- EtherNet/IP available
- Diameter: 0.1” to 20” (2.5mm to 500mm) with PFA liner
- Liner materials: Ceramic, PFA
- High Accuracy: up to ±0.15% of flow rate
- Ideal for aggressive industries:
- Oil & Gas
- Chemical
- Pulp & Paper
- Metal & Mining
- Water & Wastewater
- Explosion proof version available 0.1” to 16” (2.5 mm to 400 mm)
- Submersible version available 0.5” to 20” (15 to 500mm)
- Hygienic version available 0.5” to 5” (15 to 125mm)
- NSF61 approval for drinking water
What Are the Benefits of the ADMAG Total Insight (TI) AXG®?
Simplified Selection
Selection Tool
In just a few clicks, find the best unit for your process based on the required functionality and specifications.
Expert Guide
Wizard Function
Basic parameters that are commonly set, such as flow rate span, totalizer/pulse output, and display, are grouped together under the Easy Setup Wizard. This reduces the time taken for device startup.
Multiple Languages
Select from nine different language options: English/French/German/Italian/Spanish/Portuguese/Russian/Chinese/Japanese.
Cable Connection Check Function
For multiple remote type units that are wired and installed at the same time, often a wiring error occurs. Yokogawa has developed a method for detecting a wiring error based on changes in the signal waveforms when excitation is on and off
Process Guard
Data Logging Function
Log up to four different process variables (electrode A, electrode B, adhesion level, flow noise, velocity, volume flow, mass flow, calorie) and save onto the micro SD card. A quick troubleshooting analysis can be conducted by looking at the trend curve and alarms, and data can be downloaded and saved to analyze offline.
NAMUR Function
A total of 28 system and process alarms can be individually classified according to NAMUR NE 107. The user can adapt the action of each alarm individually to meet process requirements and prevent unnecessary alarms from distracting plant operators.
Maintenance Manager
Built-in Verification
Three levels of verification functions are available, including a built-in verification function for ADMAG TI converters that checks the magnetic circuit, excitation circuit, computing circuit, alarm history, and cable connection.
Additional functions include standard and enhanced verification that can generate the report based on the displayed results of the equipment and perform additional checks using peripheral devices. The built-in verification and standard verification are within ±5% of factory accuracy, and the enhanced verification is within ±2% of factory accuracy, guaranteeing the health of the equipment.
Application Diagnostic
The application diagnostic can be divided into two categories:
- An alarm state that detects abnormal conditions that persist in a process
- A warning state that calls for attention when signs of abnormality appear in the process
Application diagnostic can detect various process conditions of your site by actively utilizing flow noise. These include: gas bubble contain detection, electrodes corrosion detection, low conductivity detection, and slurry noise detection.
Data Mobility
Data Transfer Using microSD Card
A unique feature of the microSD allows users to back up parameter setting, trend data storage, record various data measurements for offline analysis, duplicate multiple units, and save all device data and configuration data to a PC.
Advanced Flexibility
Backward Compatibility
The new AXG4A converter can be combined with old flow sensors. The existing special signal cable and excitation cable can be utilized in addition to some of the transmitter specifications.
Worldwide Approvals
The ADMAG TI series offers explosion-proof, SIL, EMC, NAMUR and multiple communication protocols to meet the needs of all markets and applications.
Various I/O Combinations
The ADMAG TI series offers multiple combinations of I/O (includes current input) and communication types. This gives the flexibility to utilize the process information for better control in your application.
EtherNet/IP and NSF61 models are available.
Some examples are 2 analog points (2 output or 1 output and 1 input) or 2 digital points (2 pulse output, or 1 pulse input and 1 input/output).
Specification of ADMAG AXG Transmitter
AXG4A Transmitter |
AXW4A Transmitter |
AXG1A Transmitter |
|
---|---|---|---|
microSD Data Storage | Yes (Option) |
Yes (Option) |
Yes (Option) |
Build-In Verification | Yes | Yes | Yes |
Application Diagnostic | Yes Low conductivity, Bubble, Slurry etc |
N/A | Yes |
Current, Pulse, Status Output (max. channel) |
Current 2ch Pulse/Status 2ch |
Current 1ch Pulse/Status 3ch |
Current 2ch Pulse/Status 2ch |
Status Input | 1ch (Alternative) |
1ch (Independent) |
2ch (Alternative) |
Current Input (For calc. mass flow, Calorie) |
1ch (Alternative) |
N/A | 1ch (Alternative) |
Intrinsically Safe Output | 1ch (Alternative) | N/A | N/A |
Explosion Proof | FM, ATEX, IECEx | N/A | N/A |
Yokogawa Backward Compatibility | N/A | N/A | Yes |
Third-Party Flow Tubes Compatibility (DC Signal) |
N/A | N/A | Yes |
* Please refer to General Specifications in detail.
Specification of ADMAG AXG Flow Sensor
AXG Flow Sensor | AXW Flow Sensor | |
---|---|---|
Diameter | 2.5 to 500mm | 25 to 1800mm |
Liner Variation | Ceramic, PFA | PTFE, Polyurethane rubber, Hard rubber, Soft rubber |
Accuracy | ± 0.3% of rate | ± 0.35% of rate |
High Accuracy | ± 0.15% of rate 25 to 200mm |
N/A |
* Please refer to General Specifications in detail.
Definition of ADMAG AXG Flow Sensors
ADMAG AXG
Resources
ADMAG AXG Magnetic Flowmeter Helps to Optimize Production Throughput and Reduce Energy Consumption in Chlor-Alkali Plant
Yokogawa's unique simultaneous, dual-frequency excitation method used in the ADMAG TI magnetic flowmeter can enable tighter control, faster response, larger quantity of end product per batch, reduced cost, and higher profitability.
Boosting efficiency in Chlor-Alkali Plants with the ADMAG Magnetic Flowmeter provides accurate, stable flow measurement for Brine and Caustic in Chlor-Alkali electrolyzer cells, improving production efficiency and reducing energy consumption.
Angel Yeast Co., Ltd. is a leading global player in the yeast and deep-processed products industry, with production bases in 13 cities worldwide. Their yeast series products account for over 17% of the global market, ranking second globally.
In their production process, additives like nitrogen, phosphorus, and potassium are crucial, requiring accurate measurement and stabilization to ensure the final product meets specifications. Yokogawa proposed the AXG electromagnetic flowmeter as a solution, providing dual-frequency excitation for both rapid response and reduced noise.
To meet state requirements for calibration checks, use Meter Verification (part of the Total Insight concept of the ADMAG TI - AXG) to verify the calibration and functionality of each meter. The reliable accuracy of the AXG magmeter results from Yokogawa’s proprietary, dual-frequency excitation method. It combines traditional high/low-frequency excitation methods to ensure greater stability and quicker response even if noise or other problems are present in the line. With EtherNet/IP, an operator can initiate a verification from the HMI to ensure the gallery is running optimally.
Yokogawa’s latest generation of ADMAG AXG Series is the most suitable magnetic flowmeter with adhesion level diagnosis and dual-frequency excitation method provides stable flow measurement even under high flow noise in the severe applications like the flow of aluminum slurries.
With the high temperatures, pressures, and levels of dissolved organics that are encountered, the ADMAG AXG flow meter design is ideal for use in all phases of the chemical recovery process.
Questionable flow and conductivity measurements during CIP could raise questions about food quality and safety.
In order to reduce emissions of air pollutants such as sulfur oxides (SOx) and nitrogen oxides (NOx), power plants have installed flue gas desulfurization systems known as scrubbers.
Flow performance extends cell membrane life with accurate, reliable, and stable performance - saving millions of dollars in membrane repair costs, reducing instrument maintenance costs and production downtime, and production loss.
Accurate and durable magnetic flow meters (magmeters) were difficult to maintain in the process as the corrosive and abrasive nature of the process degraded their operation. That led to leaks that not only reduced the flow but also contaminated the product and the magmeters. Since Sigura maintained strong vigilance, the company needed to replace some magmeters monthly...
In today’s tightening orange juice market, facilities must improve efficiency to deliver high-quality products. With that goal in mind, a leading U.S. juice and citrus processor uses or sells each part of the orange. Nothing goes to waste. In the drive to improve efficiency, the juice and citrus products producer needed a reliable partner to help determine ways to reduce maintenance costs and deliver high returns. The producer selected Yokogawa products such as the EJAC80E Diaphragm Seal System with DPharp sensor technology for level control and monitoring, ADMAG AXG magnetic flow meters (magmeters) for flow measurement, and FLXA402 analyzers for pH and conductivity monitoring.
Yokogawa’s ADMAG TI - AXG magnetic flowmeter (magmeter) with EtherNet/IP is used to measure the water moving from the pump to the snow cannons. The accurate measurement allows the operator to monitor and control the water in the mixture to produce artificial snow with the perfect consistency.
The reliable accuracy of the AXG magmeter is a result of Yokogawa’s proprietary, dual-frequency excitation method, which combines traditional high/low-frequency excitation methods to ensure greater stability and quicker response even if noise or other problems are present in the line. The customer was very pleased with the result, as it allows him to automatically mix yogurt with cherries, which was previously impossible due to the measurement deviations.
The process consists of mixing meats, oils, and water to create a finished product, animal feed, using a PLC-based automation system.
Read this eBook to learn how to best leverage the latest measurement instrumentation to avoid incidents and improve productivity. You will also find valuable information about overcoming common CIP challenges and stories of success.
A Basic Guide to Accurate & Reliable Flow Measurement.
View Efficient Plant Article
Downloads
Brochures
- Magnetic Flowmeter Designed by Total Insight concept (10.7 MB)
- Flowmeters are Vital to Plant Operations
- Application for the Marine industry (6.0 MB)
- Yokogawa in the Food and Beverage Industry (5.9 MB)
- Flow Meter Selection Guide Poster
- Five Mistakes When Selecting a Flowmeter (440 KB)
- Electrolysis Solutions: Instrumentation Solutions for Electrolysis Plant Applications (841 KB)
- Brochure: Five Mistakes When Selecting a Flowmeter
- Mining Solutions (3.2 MB)
Instruction Manuals
- Magnetic Flowmeter Read Me First (1.2 MB)
- ADMAG TI Series AXG Magnetic Flowmeter Installation Manual - Difference to IM 01E22A01-01EN (451 KB)
- ADMAG TI – AXG/AXW Quick Setup and Reference Guide (1.8 MB)
- ADMAG TI Series AXG Magnetic Flowmeter Installation Manual (9.3 MB)
- ADMAG TI Series AXG, AXW Magnetic Flowmeter BRAIN Communication Type (5.0 MB)
- ADMAG TI Series AXG/AXW Magnetic Flowmeter Safety Manual (394 KB)
- ADMAG TI Series AXG Magnetic Flowmeter Maintenance Manual (2.7 MB)
- ADMAG TI Series AXG, AXW Magnetic Flowmeter PROFIBUS PA Communication Type (3.9 MB)
- ADMAG TI Series AXG1A Magnetic Flowmeter Remote Transmitter BRAIN Communication Type (5.3 MB)
- ADMAG TI Series AXG, AXW Magnetic Flowmeter HART Communication Type (4.8 MB)
- ADMAG TI Series AXG, AXW Magnetic Flowmeter Modbus Communication Type (2.7 MB)
- ADMAG TI Series AXG1A Magnetic Flowmeter Remote Transmitter HART Communication Type (4.8 MB)
- ADMAG TI Series AXG, AXW Magnetic Flowmeter FOUNDATION Fieldbus Communication Type (4.1 MB)
- Magnetic Flowmeter Verification Tool (44.4 MB)
General Specifications
- ADMAG TI Series AXG Magnetic Flowmeter (4.4 MB)
- ADMAG TI Series AXG Magnetic Flowmeter Remote Sensor Pulp & Paper Application Type (976 KB)
- ADMAG TI Series AXG Magnetic Flowmeter - Differences to GS 01E22A01-01EN (380 KB)
- ADMAG TI Series AXG Electromagnetic Flowmeter Marine Approval Type (762 KB)
- ADMAG TI Series AXG1A Magnetic Flowmeter Remote Transmitter (1.1 MB)
- FSA130 Magnetic Flowmeter / Vortex Flowmeter Verification Tool (1.4 MB)
- ADMAG TI Series AXG Magnetic Flowmeter EtherNet/IP Communication Type (1.7 MB)
- ADMAG TI Series AXG1A Magnetic Flowmeter Remote Transmitter - Differences to GS 01E22C01-01EN (282 KB)
Technical Information
Certificates
Videos
Discover how Yokogawa’s Total Insight Flowmeters with Process Guard transform operational safety and efficiency. In this video, we highlight its advanced capabilities in monitoring, diagnostics, and proactive intervention to minimize risks and maximize uptime.
In the digester process, high temperature and pressure, along with the slurry pulp, can cause extreme damage to traditional meters.
What about other instrumentation pain-points in the blow tank, washing, or bleaching process?
Our experts review the theory behind flow measurement technologies. Discuss common flow application challenges and evaluate the different technologies when selecting a flow meter. They also give examples of best installation practices for successful measurements.
2D/3D Configurator
Looking for more information on our people, technology and solutions?
Contact Us