EJX120A

The EJX120A is a traditional-mount draft range pressure transmitter. Featuring a DPharp digital sensor, it offers the performance and device intelligence for greater process insight.

Details

Plants run better with Yokogawa pressure transmitters. At its heart, Yokogawa's Differential Pressure Transmitter with DPharp digital sensor offers the performance and device intelligence needed to get greater insight into your process.


Digital Performance

Installed performance 2x better using all digital DPharp pressure sensor.

Yokogawa’s digital sensor provides superior performance and stability compared to analog sensors.

Poor Performance = Lost Money


Standard Diagnostics

Reduce unscheduled maintenance by 60%

Over 40 diagnostics to ensure everything is OK. Active Sensor Technology monitors the DPharp sensor while the Patented Back-check Technology is reverse checking all calculations in real-time.

Good Diagnostics = Less Surprises

What Are the Benefits of Draft Range Differential Pressure Transmitters?

 

Routine maintenance is easier with Yokogawa pressure transmitters. Efficient and effective maintenance through extended calibration intervals and simple trouble shooting.


Extended Calibration Intervals

Reduce maintenance cost by 33%.

Improved long-term stability extends calibration intervals. Spend your time where it is needed.

Quicker = Less Downtime

Calibration Interval (2018) (W=396;H=249)

 


 

Multiple Communication (2018) (W=387;H=274)

Multiple Communication Options

FieldMate PC based communication platform allows management of your entire instrument inventory.

FieldMate HHC allows you to take that information into the field.

LPS can update 9 parameters in the field without the use of an HHC.

Save time, Save money

 


 

Simple Troubleshooting

Local intuitive display with simple error messaging.

NE107 compliant alarms in FieldMate make troubleshooting easy.

Save time, Save money

 

 

Standard Protocols

No training required.

Yokogawa transmitters support all industry standard field device protocols. Interoperability and interchangeability can be ensured. Use the same tools and work procedures as before.

No Learning Curve = Smooth Change Over

 

Communication (2018) (W=400;W=253)

 


 

Standard Industry Connections

Process connections designed to meet IEC61518 ensure you will not meet proprietary manifolds or accessories that limit your design choices.

How Are Draft Range Differential Pressure Transmitters Built?

 

Ruggedness = Reliability

Yokogawa's DPharp active sensor, patented back check diagnostics, and rugged construction allow users to run their plants safer and with less downtime. Yokogawa pressure transmitters help plants run longer. The transmitters are designed to outlive your plant and can reduce failures in the field by 200%.


Over-pressure Protection

Reduce failures and calibrations.

Yokogawa DPharp pressure transmitters have an integral over-pressure mechanism to protect your transmitters from process surges or improperly sequenced manifolds.

 


Proven in Use

Less Downtime = Making Product

Over 6 million DPharp transmitters are installed worldwide.


 

Reliability Guaranteed

Reliability verified independently by third party industry experts.

 

 


 

Inherently Safe

Save up to 10% on CAPEX spending.

All Yokogawa pressure transmitters are certified to meet IEC61508 for single use in SIL 2 applications or dual use in SIL 3 applications as a standard. No special option needed! To Yokogawa, safety should never be an option.

Inherently Safe = Reliability

 


 

Active Sensor Technology

Unlike other sensor technologies, the active DPharp sensor constantly produces a signal even if there is no change in the process. This signal is continually monitored by the CPU.

.

EJX120A Overview

Measurement Types
Primary Variable Differential Pressure (Draft Range)
Reference Accuracy
Primary Variable ±0.09% of Span
Response Time
Primary Variable 150 msec
Rangeability
Primary Variable 40:1

WPC004.a

EJX120A Capsule

MSC009.a

Graphics are not to scale.

Valves

Manifolds

For Differential pressure transmitters, Yokogawa offers a complete line of 61518 IEC compliant 3-valve and 5-valve manifolds. Available in T-Style, H-Style, Wafer-Style, and Bottom Process Connection Style, they can be ASME B31.1 (Power) Compliant, ISA 15848 Compliant, or TA-Luft Compliant.

Learn More

 

Resources

Overview:

Overcome Temperature Challenges. Correct common conditions for better level measurement.

Industries:
FieldGuide
688 KB
Overview:

Extend your differential pressure transmitter's range with affordable isolation solutions, shielding it from extreme process temperatures and corrosive fluids.

Overview:

Yokogawa's cost-effective and user-friendly, differential pressure volumetric flow measurement with accuracy ranging from 0.5% to 1.5%, ensures efficient process control at a competitive price compared to other flow technologies.

FieldGuide
756 KB
FieldGuide
493 KB
FieldGuide
632 KB
FieldGuide
1.0 MB
FieldGuide
659 KB
Overview:

Discover the safety features built-in to the Yokogawa digital pressure sensors (DPharp).

FieldGuide
813 KB
FieldGuide
708 KB
FieldGuide
608 KB
FieldGuide
741 KB
FieldGuide
743 KB
FieldGuide
658 KB
FieldGuide
717 KB

Downloads

Videos

Overview:

Is it true that 4-20 mA HART will be phased out in the near future? Is a transducer equal to a transmitter? Tune in to hear the debunking of these myths.

2D/3D Configurator

Looking for more information on our people, technology and solutions?

Contact Us

Top