751574 Current Transducer, DC to 100 kHz/600 Apeak
Current Output
- Wide measurement frequency range: DC and up to 100 kHz (-3 dB)
- High-precision fundamental accuracy: ±(0.05% of reading + 40 µA)
- Wide dynamic range: 0-600 A (DC)/600 A peak (AC)
- ±15 V DC power supply, connector, and load resistor required.
For detailed information,
see Power Meter Accessory Catalog Bulletin 7515-52E.
|
 |
751552 Current Clamp on Probe, AC1000 Arms (1400 Apeak)
Current Output
- Measurement frequency range: 30 Hz to 5 kHz
- Basic accuracy: ±0.3% of reading
- Maximum allowed input: AC 1000 Arms, max 1400 Apeak (AC)
- Current output type: 1 mA/A
A separately sold fork terminal adapter set (758921),
measurement leads (758917), etc.
are required for connection to WT500.
For detailed information,
see Power Meter Accessory Catalog Bulletin 7515-52E.
751550* AC 400 Arms (600 Apeak)
Voltage Output
- Wide measurement frequency range: 20 Hz to 20 kHz (±5%)
- Basic accuracy: ±1.0% of reading ±0.2 mV
- Voltage output type: 10 mV/A
*
This model is treated as a special-order product.
|
 |
 |
 |
| |

 |
|
|
- 758917 Measurement leads
- Two leads in a set. Use 758917 in combination with 758922 or 758929.
Total length: 75 cm
Rating: 1000 V, 32 A
- 758922 Small alligator adapters
- leads (758917). Two in a set.
Rating: 300 V
- 758929 Large alligator adapters
- For connection to measurement leads (758917). Two in a set.
Rating: 1000 V
- 758923¹
Safety terminal adapter set
- (spring-hold type) Two adapters in a set.
- 758931¹
Safety terminal adapter set
- Screw-fastened adapters.
Two adapters in a set. 1.5 mm Allen wrench included for tightening.
- 758921 Fork terminal adapter
- Two adapters (red and black) to a set.
Used when attaching banana plug to binding post.
- 701959 Safety mini-clip set (hook Type)
- 2 pieces (red and black) in one set. Rating 1000 V
- 758924 Conversion adapter
- For conversion between male BNC and female banana plug
- 366924/25²
BNC cable
- (BNC-BNC 1 m/2 m)
For connection to simultaneously measurement with 2 units,
or for input external trigger signal.
- B9284LK³
External Sensor Cable
- For connection the external input of the WT500 to current sensor.
Length: 50 cm
 |
Due to the nature of this product,
it is possible to touch its metal parts.
Therefore, there is a risk of electric shock,
so the product must be used with caution.
|
| ¹ |
Maximum diameters of cables that can be connected to the adapters
758923 core diameter: 2.5 mm or less; sheath diameter: 4.8 mm or less
758931 core diameter: 1.8 mm or less; sheath diameter: 3.9 mm or less
|
| ² |
Use with a low-voltage circuit (42 V or less) |
| ³ |
The coax cable is simply cut on the current sensor side.
Preparation by the user is required.
|
|
 |
|
Connection the Measurement Cables and Adapters
|
|
Connection Diagram for Current Transducer
|
| Product |
Part no. |
Specifications |
Order quantity |
| Output connector |
B8200JQ |
D-SUB 9-pin, with 2 screws |
1 |
| Load resistors |
B8200JR |
10 Ω, 0.25 W x 4
Connect 4 in parallel to set resistance to 2.5 Ω. |
1 |
|
|
Connection Diagram for Clamp-on Probe
|
*Don't connect and use the current input terminal and EXT terminal simultaneously.
|
|
|
|
|