DAQLOGGER Integrates Yokogawa's Major Recorders, Data Acquisition Equipment, Controllers, and Measuring Instruments
|
DAQLOGGER supports a wide variety of models from among Yokogawa’s family of world-class data acquisition products.
|
Enables you to send, receive and edit settings of data acquisition equipment¹. By saving the settings, you can easily reuse them in future sessions.
1: Excluding instruments connected via Gate software.
|
|
Gate software components are interface tools that link various hardware components with DAQLOGGER.
|
 |
Features:
GateµR enables you to transfer data captured by µR10000/µR20000 Industrial Recorders to DAQLOGGER.
Functions:
- Connects up to sixteen units of the µR10000/µR20000
- Supports Ethernet and RS-422/485 communication (Only µR10000 or µR20000 can be connected to one RS-422/485 communication line.)
|
|
 |
 |
 |

 |
|
|
|
Features:
GateCONTROL is the dedicated interface software that enables you to transfer data from temperature controllers and signal conditioners to DAQLOGGER through Modbus/RTU or Modbus/TCP (An RS-232 to RS-485 converter is required to perform communications between the software and another Modbus/RTU (RS-485) device. Yokogawa ML2 RS-232 to RS-485 converter is recommended.)
Functions:
- Connects up to thirty-two controllers
- Supports Ethernet (Modbus/TCP)
- Supports RS-422/485 (Modbus/RTU)
- Enables you to acquire alarm data from temperature controllers
- Three to forty-two parameters are assigned as input tags in advance depending on the connected model. By arbitrarily specifying Modbus registers that can be read, up to forty-eight parameters can be acquired per instrument as input tags
- One to ten parameters are assigned as output tags in advance depending on the connected model. By arbitrarily specifying Modbus registers that can be written, up to thirty-two parameters can be handled per instrument as output tags, and writing to registers can be performed using the AddObserver panel.
|
 |
 |
|
GateMX/MW (Formerly GateMX100)
|
Features:
GateMX/MW is a software program that acquires data from the MX100 DAQMASTER Data Acquisition Unit and supplies that data to DAQLOGGER and the add-on software. Using GateMX/MW allows you to monitor data that can be measured by the MX100 on DAQLOGGER or Remote Monitor. (When GateMX/MW is connected to the MX100, there is no backup mode for communication disconnections even during data acquisition. No saving to a CF card can not be made. Dual Save is also not enabled even with the /DS option.)
Functions:
- Up to thirty-two MX100/MW100 can be connected via Ethernet. (for the MW100, the firmware R2.11 or later only.)
- Data measured on the MX100/MW100 is transferred to DAQLOGGER at a minimum interval of one second (DAQLOGGER connection mode).
- Measured data can be transferred separately by MX100/MW100 unit and measurement group to Add-on software at intervals as short as 10 ms (group connection mode, sixteen connections maximum).
|
 |
 |
Features:
An interface software component for transferring data acquired with DX100P/DX200P to DAQLOGGER.
Functions:
- Can link up to 16 DX100P/DX200P recorders
- Supports Ethernet, RS-232, and RS-422/485 communication interfaces
|
 |
 |
 |
Features:
GateMODBUS is linked with DAQLOGGER in order to link DAQLOGGER with clamp-on power meters and other instruments, enabling you to perform data acquisition and monitoring (By allowing direct connection to a network (Ethernet 10Base-T), wiring labor, communication converter costs, and man hours for construction of a system program can be reduced. An RS-232 to RS-485 converter is required to perform communications between the software and another Modbus/RTU (RS-485) device. Yokogawa ML2 RS-232 to RS-485 converter is recommended).
Functions:
- Read 300 tags' input registers and holding registers of each device or instrument
- Supports the Remote Terminal Unit mode of the Modbus protocol in serial communication, (data value scaling is possible)
- Permits data acquisition using Modbus function codes 03 (read holding register) and 04 (read input register)
- Supports loopback testing using Modbus function codes 08
Temperature Controllers and Signal Conditioners Network Data Acquisition 
|
 |
 |
Features:
An interface software component for transferring data acquired with WT-series power meters to DAQLOGGER.
Functions:
- Can link up to 16 WT-series power meters via GP-IB or RS-232, or Ethernet(WT1600)
- Supports the following models:
WT110, WT110E, WT130, WT200, WT210, WT230, WT1010, WT1030, WT1030M, WT1600, WT2010, and WT2030
|
 |
 |
|
Features:
GateOPC is linked with DAQLOGGER facilitating data acquisition and monitoring by linking DAQLOGGER with equipment having OPC server functions, such as a DCS or PLC, irrespective of whether they are from Yokogawa or other vendors.
Functions:
- An OPC client for linking with OPC DA servers
- Permits simultaneous data acquisition from 16 OPC DA servers
- Permits periodic data acquisition using the synchronized I/O interface of an OPC DA server
- Enables you to view the content of an OPC server from an OPC client using the browse function (OPC Browse Server Address Space option is required)
|
|
|
|
|
DAQOPC/DAQOPC for Darwin are communication interface packages that comply with the OPC standard.
|
|
|
|
|
|