Measurement of NOx Concentration
Industry: Power
Product: Infrared Gas Analyzer (SG700)
Precise Measurement of NOx Concentration of Gas Engine Exhaust to Reduce Cost of Operating NOx Removal Equipment
NOx Measurements in Denitration of Gas Engine Exhaust
zoom

Cogeneration systems that improve overall energy utilization by simultaneously generating electricity and heat from a single fuel source have been in the news a lot recently. Distributed generation equipment, a type of cogeneration system, is driven by a gas or diesel engine. Advantages of the gas engine, which is widely used, include high thermal efficiency and secure fuel supply. However, the exhaust is likely to include pollutants such as nitrogen oxides (NOx) because of the high combustion temperature in such engines. To prevent air pollution, it is critical to control the exhaust gases.
NOx removal equipment based on an ammonia injection process is commonly used to reduce NOx emissions. Optimum control of ammonia injection is achieved by NOx measurement, thereby reducing the cost of running such equipment. The highly sensitive and reliable SG700 stack gas analyzer is most suitable for the continuous measurement of NOx concentrations.

- Accurately measures NOx concentrations in gas engine exhaust
- Reduces cost of operating NOx removal equipment
- Minimizes need for equipment replacement

NOx in gas engine exhaust can be reduced by decomposition with a catalyst or the use of a reducing agent such as ammonia. Since solid catalysts have a short life, a more stable wet denitration process using liquid ammonia is generally employed. By mixing exhaust gases with ammonia, NOx is converted to harmless nitrogen and water. The reaction is expressed as follows:
           NOx + NH3 + (catalyst) --> N2 + H2O
The running cost of a liquid ammonia process is high, necessitating NOx measurements before and after the operation of NOx removal equipment to control the amount of ammonia that is injected.

Measurement system  
Probes: When sample temperature is from acid dew point (150°C) to
700 °C: Type M1E Filter Probe; P/N K9219ED
   
Stack gas analyzer (NOx, O2): Model: SG700-B-1CJNNNNNN-1☐☐☐☐.......
   
External drain separator: P/N K9641EA
   
Sampling tube: SG8SAP
   
Standard gas cylinders Zero gas cylinder for O2 calibration (Required to be purchased locally)
Span gas cylinder for NOx calibration (Required to be purchased locally)
Air for O2 span and NOx zero calibration
   
Utilities  
Power supply: 100/110/115/220/240 V AC, 50/60 Hz
Power consumption: 600 to 1000 VA, depending on specifications



Notes
An external separator should be used when:
the SG700 is installed near the sampling point. This may not allow the sample gas to cool sufficiently.
the sampling tube is long. This may allow drained liquids to accumulate in the tube, causing sample components to dissolve and leading to measurement errors.
the sampling tube is inclined at an angle of less than 15° to the horizontal.
drain may form and stay in the sampling tube.
Gas engine exhaust has a high moisture content. Care must be exercised not to allow drain pockets to form in the sampling tube. Care must also be taken to prevent excessive engine vibration.
  Installation of Typical External Sampling System
zoom
Special Notes
In Japan, NOx emission regulations apply to gas engines as well as gas turbines and diesel engines and NOx-O2 measurement of exhaust is obligatory.
Since the gas fuel has little sulfur content, sulfur dioxide (SO2) is not present in the gas engine exhaust.

Process Conditions

Measurement Point
  Inlet and outlet of NOx removal equipment, switching measurement points
 
Measuring Range
  Inlet of NOx removal equipment: 0-5000 ppm
Outlet of NOx removal equipment: 0-200 ppm
 
Benefits
  By controlling the NOx concentration to a upper limit specified in the emission regulations, the amount of ammonia injected can be saved.
Reference:
In an exhaust system with a capacity of 1000 m3, approximately 2.5 kg of liquid ammonia (concentration: 30%) is required to reduce the NOx concentration in the exhaust gases by 100 ppm.

Download printer-friendly version (296KB)