Parameter
|
Specification
|
| Method of detection |
True RMS |
| Display |
LCD(Digital display:3999 counts) |
| Response Time |
Approx. 1 second(on DC current/voltage range) |
| Approx. 2 seconds(AC current/voltage range, resistance range) |
| Range Switching |
Auto-range |
| Data Hold |
On all range (without peak hold) |
| Peak Hold |
On current/voltage range |
| Average Measeurement |
On current/voltage range |
| Ambient temperature and humidity |
0 to 40 deg.C, 85% RH or less (no condensation) |
| Temperature Coefficient |
-
|
| Influence of external magnetic field |
4A or less at 400A/m
|
| Influence of conductor position |
±(1.5% rdg + 3dgt) or less |
| Safety Standard |
Conforms EN61010-1, EN61010-2-031, EN61010-2-032 |
| Circuit Voltage |
1000Vrms or less |
| Withstanding Voltage |
5.55kV AC for one minute |
| Power Supply |
6F22(006P)9V ×1 or 6LR61 ×1 |
| Battery Life |
Approx. 15 hours (continuous) |
| Consumed Current |
Approx. 15mA |
| Sleep Function |
Automatically powered down in about 10 minutes after the last switch operation |
| Diameter of measurable conductor |
55mm at maximum |
| Dimensions |
Approx.105(W) × 250(H) × 49(D)mm |
| Weight |
Approx. 540g
|
| Accessories |
User's manual(IM CL255), Test Lead(98011), Output plug(98012), batteries, carrying case(93034) |