Parameter
Reference
Accuracy
AC Current 400/600A 1.5+5 (50/60Hz)
3.5+5 (40 to 1kHz)
DC Current 400/1000A 1.0+5
AC Voltage 40/400/600V 1.5+5 (50/60Hz)
3.5+5 (40 to 1kHz)
DC Voltage 40/400/600V 1.0+5
Crest Factor 3 or less
Resistance 400/4000Ω 1.0+5 , Beeps at below 20Ω(continuity check)
Frequency 10 to 3000Hz 1.5+5
At 23 deg.C ±5 deg.C, 75% RH or less
Accuracy: ±(% rdg + dgt) = ±(% readout + value of least significant digit)
Parameter
Specification
Method of detection True RMS
Display LCD(Digital display:3999 counts)
Response Time Approx. 2 seconds
Range Switching Auto-range
Data Hold On all range
Peak Hold On AC/DC current range, AC/DC voltage range
Average Measurement

-

Ambient temperature and humidity 0 to 40 deg.C, 90% RH or less (no condensation)
Temperature Coefficient
-
Influence of external magnetic field
-
Influence of conductor position ±2.0% or less
Safety Standard Conforms EN61010-1, EN61010-2-031, EN61010-2-032
Circuit Voltage 600Vrms or less
Withstanding Voltage 5.55kV AC for one minute
Power Supply 6F22(006P)9V ×1 or 6LR61 ×1
Battery Life Approx. 15 hours (continuous)
Consumed Current Approx. 15mA
Sleep Function Automatically powered down in about 30 minutes after the last switch operation
Diameter of measurable conductor 33mm at maximum
Dimensions Approx.91(W) × 210(H) × 40(D)mm
Weight Approx. 450g
Accessories User's manual(IM CL235), batteries, carrying case(93032)