| Accuracy (typical) |
YTA50: ±0.1% of span or ±0.2deg C(0.36deg F) YTA70: ±0.1% of span or ±0.1deg C(0.18deg F) |
| Cold junction Compensation accuracy |
(For T/C only) ±1 deg C (1.8 deg F) |
| Power supply effect |
±0.005% of FS per volt |
| Ambient temperature effect |
YTA50: (±0.1% or ±0.1deg C) / 10 deg C YTA70: (±0.05% or ±0.05deg C) / 10 deg C |
| Input signal |
Single input Input type is selectable: thermocouples, 2-, 3-, and 4-wire RTDs, ohm and DC milivolt |
| Output |
Two wire 4 to 20 mA DC |
| Supply voltage |
7 to 35 V DC (7 to 28 V DC for Intrinsically safe type) |
| Ambient temperature |
Option code may affect limits -40 to 85 deg C (-40 to 185 deg F) |
| Mounting |
DIN form B head mounting |
| Weight |
50g (0.11lb) |
Certificates |
CENELEC or FM |