EJA510A / EJA530A Direct Mount Type Absolute Pressure and Gauge Pressure Transmitter
(Measurement values below are in absolute for EJA510A) |
| A Capsule |
B Capsule |
C Capsule |
D Capsule |
| Range |
0 to 200 kPa
(0 to 29 psi) |
0 to 2 MPa
(0 to 290 psi) |
0 to 10 MPa
(0 to 1450 psi) |
0 to 50 MPa
(0 to 7200 psi) |
| Span |
10 to 200 kPa
(1.45 to 29 psi) |
0.1 to 2 MPa
(14.5 to 290 psi) |
0.5 to 10 MPa
(72.5 to 1450 psi) |
5 to 50 MPa
(720 to 7200 psi) |
| Accuracy |
±0.2% |
±0.2% |
±0.2% |
±0.2% |
| Degrees of protection |
IP67, NEMA 4X, and JIS C0920 immersion proof |
| Certificates |
FM, CENELEC ATEX, CSA, IECEx |
| Output |
4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication |
| Supply voltage |
BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model) |
| Ambient temperature |
-40 to 85 deg C (-40 to 185 deg F) (general use type)
-30 to 80 deg C (-22 to 176 deg F) (with integral indicator) |
| Process temperature |
-40 to 120 deg C (-40 to 248 deg F) (general use type) |
| Maximum overpressure |
4 MPa
(580 psi) |
4 MPa
(580 psi) |
20 MPa
(2900 psi) |
60 MPa
(8500 psi) |
| Mounting |
Direct Mounting/2-inch pipe mounting |
| Wetted parts material |
Capsule |
Hastelloy C-276 |
Process connection |
SUS316L, Hastelloy C-276 |
| Housing |
Cast aluminum alloy or SUS316 equivalent stainless steel (optional) |