Diaphragm Sealed Gauge Pressure Transmitters |
EJA438W/EJA438N A Capsule |
EJA438W B Capsule |
EJA438N B Capsule |
| Range |
-0.1 to 3 MPa
(-15 to 430 psi) |
-0.1 to 14 MPa
(-15 to 2000 psi) |
-0.1 to 7 MPa
(-15 to 1000 psi) |
| Span |
0.06 to 3 MPa
(8.6 to 430 psi) |
0.46 to 14 MPa
(66 to 2000 psi) |
0.46 to 7 MPa
(66 to 1000 psi) |
| Accuracy |
±0.2% |
±0.2% |
±0.2% |
| Degrees of protection |
IP67, NEMA 4X, and JIS C0920 immersion proof |
| Certificates |
FM, CENECEC ATEX, CSA, TIIS, IECEx |
| Output |
4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication |
| Supply voltage |
BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model) |
| Ambient temperature |
-40 to 60 deg C (-40 to 140 deg F) (general use type)
-30 to 60 deg C (-22 to 140 deg F) (with integral indicator)
It must be within the fill fluid operating temprature range |
| Process temperature |
-50 to 300 deg C (-58 to 572 deg F)
It must be within the fill fluid operating temprature range |
| Maximum working pressure |
Max. measurement range valve The working pressure must be within the flange rating. |
| Mounting |
Transmitter: 2-inch pipe mounting
Diaphragm seal: flange mounting |
| Process flange size |
Flush type: 3-inch (80mm), 2-inch (50mm)
Extended type: 4-inch (100mm), 3-inch (80mm) |
| Diaphragm material |
SUS316L, Hastelloy C-276, Tantalum, Titanium |
| Process flange material |
S25C, SUS304, SUS316 |
| Housing |
Cast aluminum alloy or SUS316 equivalent stainless steel (optional) |