EJA110A Differential Pressure Transmitter |
| L Capsule |
M Capsule |
H Capsule |
V Capsule |
| Range |
-10 to 10 kPa
(-40 to 40 inH2O) |
-100 to 100 kPa
(-400 to 400 inH2O) |
-500 to 500 kPa
(-2000 to 2000 inH2O) |
-0.5 to 14 MPa
(-70 to 2000 psi) |
| Span |
0.5 to 10 kPa
(2 to 40 inH2O) |
1 to 100 kPa
(4 to 400 inH2O) |
5 to 500 kPa
(20 to 2000 inH2O) |
0.14 to 14 MPa
(20 to 2000 psi) |
| Accuracy |
±0.075% |
±0.065% |
±0.065% |
±0.065% |
| Degrees of protection |
IP67, NEMA 4X, and JIS C0920 immersion proof |
| Certificates |
FM, CENELEC ATEX, CSA, IECEx |
| Output |
4 to 20 mA DC, FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication |
| Supply voltage |
BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model) |
| Ambient temperature |
-40 to 85 deg C (-40 to 185 deg F) (general use type)
-30 to 80 deg C (-22 to 176 deg F) (with integral indicator) |
| Process temperature |
-40 to 120 deg C (-40 to 248 deg F) (general use type) |
| Maximum working pressure |
16MPa(2300psi) 3.5MPa(500psi) for L capsule with special materials |
| Mounting |
2-inch pipe mounting |
| Wetted parts material |
Capsule |
SUS316L(Diaphragm material is Hastelloy C-276), Hastelloy C-276, Tantalum, Monel |
| Cover flange |
SUS316, Hastelloy C-276, Monel |
| Housing |
Cast aluminum alloy or SUS316 equivalent stainless steel (optional) |